![Chigo CCA-18HR1 Скачать руководство пользователя страница 105](http://html1.mh-extra.com/html/chigo/cca-18hr1/cca-18hr1_technical-manual_2601241105.webp)
R410A50Hz Universal Outdoor Series Technical Manual Floor & Ceiling Indoor Unit
102
GD Chigo Heating & Ventilation Equipment Co., Ltd.
6.Capacity Table
Cooling
6.1 CUA-18HR1
MODEL
CUA-18HR1
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
21ºC D
15ºC W
Total capacity Kw
5.21
4.98
4.79
4.52
4.36
4.21
Sensitive capacity kW
4.16
3.96
3.84
3.61
3.47
3.35
Input kW.
1.18
1.36
1.53
1.69
1.86
2.03
24ºC D
17ºC W
Total capacity kW
5.7
5.47
5.26
4.95
4.78
4.61
Sensitive capacity kW
4.56
4.35
4.2
3.96
3.811
3.71
Input kW.
1.21
1.42
1.61
1.79
1.97
2.15
27ºC D
19ºC W
Total capacity kW
6.2
5.95
5.71
5.3
5.16
5.01
Sensitive capacity kW
4.95
4.74
4.55
4.31
4.13
4.03
Input kW.
1.31
1.51
1.71
1.78
2.07
2.26
32ºC D
23ºC W
Total capacity kW
7.13
6.84
6.57
6.22
5.94
5.77
Sensitive capacity kW
5.69
5.45
5.25
4.95
4.75
4.62
Input kW.
1.51
1.72
1.96
2.17
2.38
2.61
6.2 CUA-24HR1
MODEL
CUA-24HR1
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
21ºC DB
15ºC WB
Total capacity kW
6.85
6.55
6.31
5.94
5.71
5.54
Sensitive capacity kW
5.47
5.24
5.04
4.75
4.56
4.43
Input kW.
1.68
1.91
2.15
2.4
2.65
2.91
24ºC DB
17ºC WB
Total capacity kW
7.52
7.18
6.91
6.52
6.26
6.05
Sensitive capacity kW
6.01
5.74
5.53
5.21
4.98
4.84
Input kW.
1.78
2.01
2.27
2.52
2.78
3.06
27ºC DB
19ºC WB
Total capacity kW
8.15
7.79
7.51
7.10
6.81
6.58
Sensitive capacity kW
6.51
6.24
5.98
5.66
5.44
5.26
Input kW.
1.87
2.13
2.39
2.54
2.93
3.22
32ºC DB
23ºC WB
Total capacity kW
9.37
8.96
8.63
8.16
7.82
7.57
Sensitive capacity kW
7.49
7.17
6.91
6.51
6.25
6.05
Input kW.
2.15
2.42
2.75
3.05
3.39
3.69
6.3 CUA-36HR1
MODEL
CUA-36HR1
COOLING
OUTDOOR TEMPERATURE DRY
Indoor Conditions
21ºC
25ºC
30ºC
35ºC
40ºC
45ºC
21ºC DB
15ºC WB
Total capacity kW
10.12
9.68
9.33
8.81
8.45
8.18
Sensitive capacity kW
8.09
7.75
7.46
7.03
6.75
6.55
Input kW.
2.34
2.68
3.02
3.41
3.73
4.07
24ºC DB
17ºC WB
Total capacity kW
11.1
10.61
10.23
9.64
9.26
8.96
Sensitive capacity kW
8.87
8.48
8.16
7.72
7.42
7.15
Input kW.
2.47
2.83
3.19
3.58
3.94
4.3
27ºC DB
19ºC WB
Total capacity kW
12.06
11.54
11.12
10.50
10.1
9.75
Sensitive capacity kW
9.65
9.24
8.89
8.38
8.04
7.79
Input kW.
2.64
3.03
3.37
3.79
4.15
4.48
32ºC DB
23ºC WB
Total capacity kW
13.86
13.26
12.78
12.06
11.58
11.21
Sensitive capacity kW
11.09
10.61
10.23
9.65
9.26
8.97
Input kW.
3.01
3.46
3.91
4.33
4.75
5.16