R410A50Hz Universal Outdoor Series Technical Manual control
130
GD Chigo Heating & Ventilation Equipment Co., Ltd.
Note:
1. Do not handle the button with nail or other sharp things, so as avoid the damages of
operation panel.
2. Thanks to technical renovation, the operation panel or remote controller may be changed
without further notice.
1. Operation mode:
Operation method of COOL/DEHUMIDIFY/HEAT (VENT)
1) Press ON/OFF button to start unit.
2) Press MODE button to select desired mode Select VENT mode and the compressor stops.
3) Press temperature + / - button to set the desired room temperature. Room temperature
setting ranges from 18
℃
to 29
℃
.
4) Press FAN button to select the desired high speed, mid speed or low speed of Fan. Fan works
only at low speed during DEHUMIDIFY mode.
5) Press ON/OFF again to stop. To protect the air conditioner from starting immediately after
stopping, the delayed start function will keep the air conditioner idle for 3 minutes before
automatically starting it.
Note: When the temperature of surroundings is less than 21
℃
or more than 43
℃
, do not
operate the COOL mode.
When the temperature of surroundings is less than -7
℃
or more than 24
℃
, do not operate the
HEAT mode.
When the indoor temperature is less than 18
℃
, do not transformed to the DEHUMIDIFY mode.
2. Timing operation
Timing OFF operation: Set the OFF time and the air conditioner will automatically stop at the set
time.
1) While the air conditioner is running , press the TIMING button , and the air conditioner enters
timing OFF state, and
"
TIMING OFF
"
and
"
TIMING
"
lamps will be on.
2) Press + or - button to set the desired timing OFF time. The set time ranges From 1 to 12 hours.