Instruction Manual
1310 3012 02
59
CPS
4.10
Coolant check
In order to guarantee the lifetime and quality of the product, thus to optimise engine protection, regular
coolant-condition-analysis is advisable.
The quality of the product can be determined by three parameters:
Visual check
•
Verify the outlook of the coolant regarding colour and make sure that no loose particles are floating
around.
pH measurement
•
Check the pH value of the coolant using a pH-measuring device.
•
The pH-meter can be ordered from Chicago Pneumatic with part number 2913 0029 00.
•
Typical value for EG = 8.6.
•
If the pH-level is below 7 or above 9.5, the coolant should be replaced.
Glycol concentration measurement
•
To optimise the unique engine protection features of the GENCOOL EG the concentration of the
Glycol in the water should be always above 33 vol.%.
•
Mixtures with more than 68 vol.% mix ratio in water are not recommended, as this will lead to high
engine operating temperatures.
•
A refractometer can be ordered from Chicago Pneumatic with part number 2913 0028 00.
Never remove the cooling system filler cap while coolant is hot.
The system may be under pressure. Remove the cap slowly and only when coolant
is at ambient temperature. A sudden release of pressure from a heated cooling
system can result in personal injury from the splash of hot coolant.
In case of a mix of different coolant products this type of measurement might provide
incorrect values.
Содержание CPS 750
Страница 1: ...Instruction Manual for Portable Compressors English CPS 750 ...
Страница 2: ......
Страница 8: ...CPS 750 8 1310 3012 02 CPS ...
Страница 86: ...CPS 750 86 1310 3012 02 CPS ...
Страница 90: ...CPS 750 90 1310 3012 02 CPS 9 Dataplate ...
Страница 92: ...CPS 750 92 1310 3012 02 CPS ...
Страница 93: ......
Страница 94: ...01 2009 1310 3012 02 ...