3.3.2
During operation
Regularly carry out following checks:
1
That the regulating valve (RV) is correctly adjusted, i.e. starts decreasing the engine speed when
reaching the preset working pressure in the receiver.
2
Check the air outlet temperature of the compressor element.
3
Check the engine oil pressure, the coolant temperature and all lamps for normal readings.
4
Avoid the engine running out of fuel. Nevertheless, if this happens, fill the fuel tank and prime the fuel
system to speed up starting (see section
5.3.2 Fuel system - Prime
).
The doors must be closed during operation and may be opened for short periods
only.
When the engine is running the air outlet valves (ball valves) must always be put in
fully opened or fully closed position.