MISCELLANEOUS PRECAUTIONS

1. 

WARNING!

 Some dust created by power sanding, sawing, grinding, drilling, 

and other construction activities, contain chemicals known (to the State of Califor-
nia) to cause cancer, birth defects or other reproductive harm.  Some examples 
of these chemicals are: lead from lead-based paints, crystalline silica from bricks 
and cement or other masonry products, arsenic and chromium from chemically 
treated lumber.  Your risk from these exposures varies, depending on how often 
you do this type of work.  To reduce your exposure to these chemicals: work in 
a well ventilated area, and work with approved safety equipment, such as those 
dust masks that are specially designed to filter out microscopic particles. 
(California Health & Safety Code § 25249.5, 

et seq.

)

2. 

WARNING!  

People with pacemakers should consult their physician(s) before 

using this product.  Operation of electrical equipment in close proximity to a heart 
pacemaker could cause interference or failure of the pacemaker.

3. 

WARNING!  

The warnings and cautions discussed in this manual cannot 

cover all possible conditions and situations that may occur.  It must be under-
stood by the operator that common sense and caution are factors which cannot 
be built into this product, but must be supplied by the operator.

SAVE THESE INSTRUCTIONS

GROUNDING

WARNING!

Improperly connecting the grounding wire can result in the risk of electric

shock.  Check with a qualified electrician if you are in doubt as to whether the 

outlet is properly grounded.  Do not modify the power cord plug provided with

the tool.  Never remove the grounding prong from the plug.  Do not use the

tool if the power cord or plug is damaged.  If damaged,  have it repaired by

a service facility before use.  If the plug will not fit the outlet, have a proper

outlet installed by a qualified electrician.

GROUNDED TOOLS: TOOLS WITH THREE PRONG PLUGS 

1. 

Tools marked with “Grounding Required” have a three wire cord and three prong   
grounding plug.  The plug must be connected to a properly grounded outlet.  If    
the tool should electrically malfunction or break down, grounding provides a low    
resistance path to carry electricity away from the user, reducing the risk of elec-   
tric shock.  

(See Figure A, next page.)

Содержание Chicago 94560

Страница 1: ...ights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions plea...

Страница 2: ...e the invoice number on the inside of the front cover Keep this manual and invoice in a safe and dry place for future reference PRODUCT SPECIFICATIONS Electrical Requirements 120 VAC 60 Hz Speed 800 3...

Страница 3: ...contact with grounded surfaces such as pipes radiators rang es and refrigerators There is an increased risk of electric shock if your body is grounded 7 Do not expose power tools to rain or wet condit...

Страница 4: ...may lead to loss of control 17 Do not force the tool Use the correct tool for your application The correct tool will do the job better and safer at the rate for which it is designed 18 Do not use the...

Страница 5: ...aw These carry important infor mation If unreadable or missing contact Harbor Freight Tools for a replacement Always wear safety impact eye goggles and heavy work gloves when using the Jigsaw Using pe...

Страница 6: ...om nails and any other foreign objects which can damage the Saw Blade Always check to make sure there are no electrical wires or cables in the cutting path of the Jigsaw Allow the Saw Blade to run up...

Страница 7: ...e pacemaker 3 WARNING The warnings and cautions discussed in this manual cannot cover all possible conditions and situations that may occur It must be under stood by the operator that common sense and...

Страница 8: ...tlet should look like those in the following illustration See Figure A FIGURE A 120 VOLT GROUNDED ELECTRICAL OUTLET THIS PRODUCT DOES NOT USE A 3 PRONG PLUG DOUBLE INSULATED TOOLS TOOLS WITH TWO PRONG...

Страница 9: ...f you are using one extension cord for more than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Figure C 6 If you are using an extension cord outdoo...

Страница 10: ...e Switch to turn on the Jigsaw and releasing pressure on the Switch to turn off the Jigsaw See Figure E 3 Switch Lock 30 The Jigsaw is equipped with a Power Switch lock mechanism To operate the tool f...

Страница 11: ...Chute 54 Use the accessory Hex Wrench 66 to loosen the Hex Screw 53 located on the underside of the Base Plate Cover Adjust the Base Plate Cover to the desired angle Then retighten the Hex Screw and...

Страница 12: ...eing cut See Figure F 3 Open the Plastic Blade Guard 58 Press the clamp button on the Blade Chuck 24 Insert the Saw Blade 68 69 as far as it will go making sure the teeth of the Saw Blade face to the...

Страница 13: ...utlet 6 Position the Saw Blade 68 69 of the Jigsaw about 1 2 from the beginning cut line on the workpiece Do not allow the Saw Blade to come in contact with the workpiece 7 Turn the Laser Switch 35 to...

Страница 14: ...by a qualified service technician TROUBLESHOOTING Problem Possible Solution Jigsaw will not run or runs with insufficient power Make sure to firmly squeeze the Power Switch See Figure E Make sure the...

Страница 15: ...minum Guard 1 58 Plastic Blade Guard 1 59 Blade Holder 1 60 Nameplate 1 61 Nameplate 1 62 Internal Wire 1 63 Junction Port 1 64 Cable Guard 1 65 Power Cord Plug 1 66 Hex Wrench 1 67 Screw ST4 2 x 19 F...

Страница 16: ...0 444 3353 PAGE 16 ASSEMBLY DIAGRAM NOTE Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts 68 Wood Cutting Blades not shown 69 Meta...

Отзывы: