4
MAINTENANCE AND REPAIR
The G702A has been manufactured to give maximum service with minimum care. In order that this may be accomplished, the following
recommendations should be followed:
1.
The hydraulic system should be full of oil and free from air at all times.
2.
Keep excessive moisture and dirt out of air supply to prevent wear of air valve, air cylinder and air piston.
3.
Tool should be routinely inspected for oil leaks.
Use automatic transmission fluid Type "A" (no substitutes). CHERRY® recommends using ATF, Dexron® Ill.
PROPERTIES
Specific gravity
0.863
Weight per gallon
7.18 lbs.
Open flash point
>200°C (392°F)
FIRST AID
Skin:
Wash thoroughly with soap and water as soon as possible. Casual contact requires no immediate attention. If
irritation develops, consult a physician.
Ingestion: Seek medical attention immediately. DO NOT INDUCE VOMITING.
Eyes: Flush with copious amounts of water. If irritation develops, consult a physician.
Inhalation: No significant adverse health effects are expected to occur on short term exposure. Remove from
contaminated area. Apply artificial respiration if needed. If unconscious, consult physician.
FIRE
Suitable extinguishing media: CO2, dry powder, foam or water fog. DO NOT use water jets.
ENVIRONMENT
Waste Disposal: In accordance with local, state and federal regulations.
Spillage: Prevent entry into drains, sewers and water courses. Soak up with diatomaceous earth or other inert
material.
Store the spent fluid in appropriate containers for disposal.
HANDLING
Eye protection required. Protective gloves recommended. Chemically resistant boots and apron recommended.
Use in well-ventilated area.
COMBUSTIBILITY
It is slightly combustible when heated above flash point. It will release flammable vapors which can burn in open or
be explosive in confined spaces if exposed to source of ignition.
STORAGE
Avoid storage near open flame or other sources of ignition.