TM-G702A
Rev.: D, 4-30-15, DCR# 15-0423
Federal Identification Code: 11815
© 2015 Cherry Aerospace
Page
3
PUTTING THE TOOL IN SERVICE
Tool without integral Air Pressure Regulator (P-1505)
AIR
SOURCE
EXTERNAL
PRESSURE
REGULATOR
Tool with Integral Air Pressure Regulator (P1505)
AIR
SOURCE
CHERRY
PROVIDED
AIR
REGULATOR
HOW TO USE THE G702A
After selecting the proper pulling head and attaching it securely to the G702A, connect the air line to the tool. Insert the rivet stem into the pulling
head until the head of the rivet is in contact with the pulling head sleeve. This will ensure full engagement between the jaws and the rivet stem
and will prevent slippage.
Once the rivet stem is inserted in the H702-3NPR pulling head, the rivet must be installed. Insert the rivet into the application and
pull the trigger to activate the tool. Upon the release of the trigger, the stem will eject to the rear of the tool.
If unclear, contact a CHERRY® representative.