background image

Page 1 of 11 

 

 

 

CR-2 Instruction Manual 

Effective Dec 19

th

 2013 

 

Содержание CR-2

Страница 1: ...Page 1 of 11 CR 2 Instruction Manual Effective Dec 19th 2013 ...

Страница 2: ...Page 2 of 11 Contents Tool Properties Technical Specifications Safety Instructions Tool Preparation Operating Instructions Maintenance and Service Exploded Drawing Parts List 3 4 5 6 7 8 10 11 ...

Страница 3: ...trength blind rivet with 3 16 diameter i e monobolt interlock etc Adjustable vacuum system for powering on and off mandrel retention function The tool can operate without the mandrel container The tool can mount the rivet in single operation Effective air pressure is 44 to 102 psi Max pull force is 2473 lb CNC machined quality components ensures long life Mandel container can be turned easily for ...

Страница 4: ...l Specification Rivet size Diameter 0 125 1 89 inches for standard rivets Diameter 0 189 inches for high strength structural blind rivet Air pressure 11 0 15 4 lbf Stroke 0 787 inches Pull force 5 Bar 2472 lb Weight 3 20 lb ...

Страница 5: ... to any medium other than compressed air Set the air pressure between 42 to 101 psi Do not use the tool for purpose other than installing rivets The tool must be maintained in a safe working condition at all times and examined at regular intervals for damage Do not dismantle this tool without prior reference to the maintenance and service instructions Always disconnect the air pipe from the tool i...

Страница 6: ...upply must be free of moisture and particles Use dry and clean materials hose couplings fittings etc to connect the tool to the filter Check for leakage in the compressed air supply If here is leakage replace the damaged hoses or coupling Drain the condensate from the filter Also check the dirt filter Check the compressed air supply pressure The tool must be fitted with correct nosepiece 01 and pu...

Страница 7: ...r counter clockwise Air suction will allow the rivet to be held in any orientation See figure 2 Attention If you don t want to use vacuum system you can turn vacuum security system clock wise and turn it off 3 Direct the riveter with rivet to the hole and then pull the trigger The stems automatically reverse to the collector and the rivet is set Fig 1 Fig 2 ...

Страница 8: ...box 1 Disconnect air supply to tool and switch ON OFF valve 48 to OFF position 2 Remove seal screw 84 and seal 83 See figure 3 3 Screw the priming pump oil into the bleed screw hole Press down and release several times until resistance is felt See figure 4 4 Remove the priming pump and the excessive oil will flow out Clean out the excessive oil and replace the seal screw and seal Fig 3 Fig 4 ...

Страница 9: ...tly The spring may be worn out or broken The oil may be insufficient There is oil or air leakage somewhere Check the nosepiece jaws jaw carrier and out cylinder Replace the defective coupling and components Add hydraulic oil The rivet cannot be put into the tool nosepiece The stem may be obstructed The vacuum system may not be in good condition Check the jaws Adjust the vacuum security system to t...

Страница 10: ...Page 10 of 11 ...

Страница 11: ...embly CR 2 62 On Off assembly CR 2 20 Lip seal meas 14 11 6 3 CR 2 63 Air valve rod CR 2 21 Retaining nut CR 2 64 Screw plug CR 2 22 O ring meas 26 7 30 26 1 78 CR 2 65 Silencer CR 2 23 Lip seal meas 22 30 6 CR 2 66 Cylinder cover CR 2 24 Axis CR 2 67 O ring meas 66 2 CR 2 25A Restore Spring CR 2 68 Bolt CR 2 26 O ring meas 35 1 5 CR 2 69 Rock nut CR 2 27 EL meas 8 14 2 5 CR 2 70 Buffer CR 2 28A E...

Отзывы: