background image

 

Please visit OPW’s website:

 

www.opwglobal.com

 for further 

information or contact OPW Customer 

Service at 

+44 (0) 1756 799 773

 

(EU) 

or 

1-800-422-2525

 

(US) 

 

 

opwglobal.com 

 

 

DEFINING

 | WHAT’S NEXT

 

214916 revision A 

September 2019 

 

21 Series Automatic Nozzles for Active Vapour Recovery Systems 

 
 
 
 

Important Safeguards 

  For your protection, please read these safety 

instructions completely before installing and 

operating this equipment. 

  Keep this manual on file for future reference. 

  This manual contains material that may be 

required by authorities having jurisdiction to 

be on site at all times. 

  Carefully observe all warnings, precautions 

and instructions for this equipment and in the 

operating instructions and adhere to them. 

 
 
 
 

 

THIS MANUAL MUST BE LEFT WITH FACILITY MANAGEMENT

 

 

Models: 21AG, 21AGV, 21BG, 21BGV – EN 13012:2012 Type I 
0530   II 1G 
Sira 19ATEX9106U  
XXXXXXXXXXXXXX serial number with date code 
OPW 
Please visit 

www.opwglobal.com

 to view a copy of the examination certificate and efficiency certificates. 

 

SITE NAME: 

 

ADDRESS: 

 

NOZZLE SERIAL NUMBER: 

 

DATE INSTALLED: 

 

INSTALLATION CONTRACTOR: 

 

Содержание OPW 21 Series

Страница 1: ... on file for future reference This manual contains material that may be required by authorities having jurisdiction to be on site at all times Carefully observe all warnings precautions and instructions for this equipment and in the operating instructions and adhere to them THIS MANUAL MUST BE LEFT WITH FACILITY MANAGEMENT Models 21AG 21AGV 21BG 21BGV EN 13012 2012 Type I 0530 II 1G Sira 19ATEX910...

Страница 2: ... electricity can ignite petrol vapours and cause a fire Fill approved portable containers on the ground It is dangerous to put petrol into an unapproved container Keep nozzle in contact with the container until finished filling to discharge any static generated during fueling When filling an approved portable container flow fuel at low flow rate to prevent static build up DO NOT put trigger in rac...

Страница 3: ... grounded vented metal test container and megohmmeter CONTINUITY TEST After installation of hanging hardware and prior to flow test check continuity following EN 60204 1 for proper test equipment and method of testing WARNING Fueling equipment is designed to operate in a pressure range of 0 5 to 3 5 bar If the pressure exceeds 6 bar the nozzle will open regardless of lever position Exceeding maxim...

Страница 4: ...ed for fuel on the ground prior to and during test Nozzle must be in contact with the container until the testing is complete to discharge any static generated during the test 7 Dispense approximately 20 litres of fuel into an approved test container with the nozzle lever held in the full open position 8 Calculate A L ratio by dividing the volume of vapour collected by the volume of fuel dispensed...

Страница 5: ...djusting vapour flow rates Retest and verify that adjustments now bring the A L ratio into compliance 8 Reseal the UST vapour system after the A L ratios are set for all fueling points WARNING Static electric spark could ignite fuel causing a fire Place a container approved for fuel on the ground prior to and during test Nozzle must be in contact with the container until the testing is complete to...

Страница 6: ... Perform continuity test See testing instructions WARNING FIRE HAZARD SPILL HAZARD CHEMICAL EXPOSURE Replace the nozzle if the nozzle fails any of the above tests or inspections Failure to comply could result in property damage injury or death REPLACEMENT PARTS DO NOT reuse O rings or screws when replacing components Only use authorized OPW replacement kits from the distributor All other modificat...

Страница 7: ...laims must be made in writing and delivered during the applicable warranty period to OPW at OPW 9393 Princeton Glendale Road Hamilton Ohio USA 45011 Attention Customer Service Manager No products may be returned to OPW without its prior written authority This limited warranty shall not apply to any FlexWorks or VAPORSAVER product unless it is installed by an OPW attested installer This limited war...

Страница 8: ...bmitting a warranty claim OPW NOZZLE WARRANTY TAG SITE Phone Number City Contact Country Distributor Branch Customer RGA Number Nozzle Model Serial Number Replacement Serial Number WARRANTABLE DEFECTS CHECK ONLY ONE Leaks Fuel Around Spout 200 Dispenses Fuel Without Pulling Lever 200 Leaks Fuel in Trigger Area 200 Fails Pressure Decay Test 300 Leaks Fuel at Hose Inlet 200 Fails Air to Liquid Test ...

Отзывы: