background image

1. INTRODUCTION

This Micro 

Centrifuge 

offers 

versatility,  simplicity,  safety, 

and 

ease 

of 

usage 

in 

single package. 

This 

product 

has been 

designed 

after 

studying centrifuges 

and its 

usage in numerous scenarios of the lab environment. 
This Micro 

centrifuge 

is 

specially 

suitable for 

microfiltration, 

cell 

separations, 

centrifugal 

tube 

sedimentation, 

and 

spin 

down 

applications. 

Please read this 

manual 

thoroughly 

before 

operating 

the 

centrifuge. 

2. INTENDED USE

This Micro 

Centrifuge 

is used in various laboratories to 

separate particles 

from 

suspension 

or 

even 

macromolecules from solutions 

according 

to their 

density. 

The different 

biological 

substances that 

are usually separated by  centrifugation 

are microbial 

cells, organelles, proteins, DNA, 

and RNA. 

Note: This user guide is intended to assist with the operation and care of the nit only and not for 

its repair. The customer should not attempt to service or repair the unit. If repairs are required, 

please contact the supplier. 

3. FEATURES

• BLDC motor for maintenance 

free long 

life

• 8 Position closed micro tube rotor
• Closed rotor leads to 

lesser friction, reducing 

noise 

heat 

generation

• Digital display
• Highly 

efficient 

accurate

• Electronic 

safety 

brake on lid 

opening 

for user 

safety

• Quick 

start 

& stop 

for short 

spin

• Smooth and 

quiet running

• Tiny footprint: 

It can squeeze 

easily 

on to a crowded 

counter top

• Interchangeable 

PCR rotor 

& adaptor

• Low voltage 

instrument with external power 

adaptor

• Speed 

and time 

setting function

• Digital 

timer 

programming 

function

• Variable 

speed settings 

RPM Increments At 100 rpm

• Imbalance cut off for 

safety

II 

Содержание Capp Rondo CLS-1602-006

Страница 1: ...CLS 1602 006 MINI CENTRIFUGE DIGITAL TIMER ADJUSTABLE RPM CAPP RONDO USER MANUAL...

Страница 2: ...2 STANDARD ACCESSORIES 2 6 SAFETY PRECAUTIONS 2 7 INSTALLATION 3 8 STANDARD PART LISTING 4 9 ROTOR BALANCING 4 10 INTERCHANGEABLE ROTOR 5 11 CHANGING THE ROTOR 5 12 OPENING CENTRIFUGE LID 6 13 OPERATI...

Страница 3: ...ated by centrifugation aremicrobialcells organelles proteins DNA andRNA Note This user guide is intended toassist with the operation and care ofthe nit onlyand notfor its repair The customer should no...

Страница 4: ...er Adaptor lnputvoltage 100 240VAC 50 60Hz Outputvoltage 24V 1 5A Product User Manual WarrantyCardand DeclarationConformity 6 SAFETY PRECAUTIONS The personal micro centrifuge is designed to be safe un...

Страница 5: ...case the unit is dropped from the table please check the casing for any cracks damage Thecentrifuge anditscomponentsare non autoclavable Donotuse thecentrifugein any manner notspecifiedin theseinstruc...

Страница 6: ...952 1868 8 STANDARDPARTSLISTING PROTECTIVE LID ON OFF SWITCH 1 n eJ 11 t POWER KNOB 9 ROTOR BALANCING NON SLIP RUBBER BASE SOCKET 1 Alwaysbalancetherotor before centrifugation The following aresymmetr...

Страница 7: ...8 Different types of test tubes can be centrifuged by using two interchangeable rotors 10 INTERCHANGEABLEROTOR ROTOR_B SLOT 8x0 2 0 4 0 5 1 5 2ml 11 CHANGINGTHEROTOR PCRROTOR 16x0 2ml Insert the hexag...

Страница 8: ...direction and the loosening will be in counter clockwisedirection Sticker Mark __ Grub Screw To ghte 7 Key t l To loosen Motor Shaft 12 OPENING CENTRIFUGE LID Wrong Method Button Trying toopen the ce...

Страница 9: ...damage to the centrifuge 4 Close thelid flip ON thefront switch to start centrifugation 5 Once the centrifugation is completed turn the front switch to Off to gradually stop therotor 6 After the roto...

Страница 10: ...the time and speed will be displayed alternatively accompanied by speed indicator andtimeindicator respectively Quick spin function By keeping the timer to position and speed set to any desired setti...

Страница 11: ...to show En or dS toshow activestatus UNBALANCE DETECTIONAND CUTOFF When imbalance detection is activated En if centrifuge is running with an unbalanced rotor by not placing the weights on the rotor e...

Страница 12: ...t is warranted to be free from defects in material and workmanship for a period oftwo 2 years fromdate ofpurchase Your product willbe duly repaired uponprompt notificationincompliance withthefollowing...

Страница 13: ...In case the product is to be disposed of the relevant legal regulations are to be observed Information on the disposal of electrical and electronic devices in the European Community The disposal of el...

Страница 14: ...00 North Mill Road Vineland NJ 08360 Phone US Canada 1 800 843 1794 International 1 856 696 0014 Fax US Canada 1 800 922 4361 International 1 856 696 9102 www cglifesciences com tech cglifesciences co...

Отзывы: