Publication 81-9059-0595-0, Rev. C
October 2010
Proprietary Information of
PESA
3-7
3.6.1.1
Power Cabling and Circuit Breakers
The 864XR chassis is supplied with a power cabling assembly (see Figure 3-4) that meets and/or
exceeds the requirements for dedicated input service lines rated for 200-240VAC at 30 amps
minimum. Two main circuit breakers are mounted on the front side of the 864XR frame in the
upper left corner. Table 3-1 describes the power connections for the associated pigtail cabling
conductors.
Table 3-1 - Pigtail Cabling Conductor Power Connections
Color Code
200-240V
Green/Yellow Stripe
Safety Ground
Blue
AC Line
Brown
AC Line
Figure 3-4 - Pigtail Cabling Conductors
3.6.1.2
External AC Power Requirements
Each 864XR chassis is supplied with pigtail cabling (see Figure 3-4 and refer to Tables 3-1) rated for
200-240VAC at 30 amps. The router is to be connected only to a dedicated service line capable of
providing the power source specified in Table 3-2.
Table 3-2 - AC Power Filter Assembly
AC Power Cable
Minimum Amps
Required
Service Drops
200-240V Attached Power Cable Pigtails
30A Service
1-Standard
1-Redundant
3.7
I
NTERNATIONAL
P
OWER
R
EQUIREMENTS
F
OR
C
HEETAH
C
HASSIS
All 864XR frames have two AC (or DC) main power feeds. For international use only, these power
feeds are isolated from each another through a special wiring configuration that is completed at the
factory (Figure 3-5).
Green/Yellow
Stripe
Blue
Brown