Mounting

 

 

 

Orientation 

 

 

 

The Intimidator™ Scan LED 300

 

may be mounted in any position provided there is adequate 

room for ventilation. 

 

 

Rigging 

 

 

 

Be sure that the structure can support the weight of the fixture. Please see the “Technical 
Specifications” section of this manual for a detailed weight listing. Mount the fixture securely. This 
may be done with a screw, nut and bolt, or a hanging clamp. The hole in each bracket is 13 mm 
in size. When rigging, consider routine maintenance and control panel access. Please see the 
following notes on installation. 
 

 

If the power link out is intended to be used with multiple fixture, take into account the 
length of each power cable, and mount the fixtures close enough to one another to 
accommodate for this. 

 

When aiming the fixtures, you may use the bracket/yoke adjustment knob(s). Loosen 
the knob(s), adjust to the desired angle, and then tighten the knob(s) by turning 
clockwise. Do not use tools for this step, as it may cause damage. 

 

Safety cables must always be used. 

 

 

 

 

 

 

 

There are two (2) rigging options available for this product. If using the hanging bracket, 
then you must use a clamp or a nut & bolt to secure the product. If using the four rubber 
feet, then the hanging bracket is not necessary and may be removed is you desire. 

 

 

 

When the product is in the sitting position (using the four rubber feet), the product must 
be secured so that it is stable and safe from falling down. 

 

 

 
 

 

Hanging Bracket 

Bracket Adjustment 

Knob 

Rubber Feet 
(1 of 4) 

Bracket Adjustment 
Knob 

Содержание Intimidator Barrel LED 300

Страница 1: ...User Manual...

Страница 2: ...igging 8 4 OPERATING INSTRUCTIONS 9 USING THE CONTROL PANEL 9 MENU MAP 9 CONFIGURING THE STARTING ADDRESS 9 OPERATION 10 DMX Operation 10 Master Slave Mode Sound Active Auto Mode 10 Automatic Slow 10...

Страница 3: ...ion from the regular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one ca...

Страница 4: ...disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 1...

Страница 5: ...Page 5 of 17 Intimidator Scan LED 300 User Manual Rev 3 2 INTRODUCTION Product Dimensions...

Страница 6: ...Page 6 of 17 Intimidator Scan LED 300 User Manual Rev 3 Product Overview Bracket Adjustment Knob DMX In DMX Out Power Out Fuseholder Power In Voltage Selection Switch 115 230 VAC Safety...

Страница 7: ...he fixture to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used only as a 0 to 100 switch Always connect the fixture to a circuit with a suitable electrical...

Страница 8: ...ake into account the length of each power cable and mount the fixtures close enough to one another to accommodate for this When aiming the fixtures you may use the bracket yoke adjustment knob s Loose...

Страница 9: ...tandalone Slave receive mode NStS SrUn Standalone Slow NAFA FASt Standalone Sound active Pan Invert PAN rPAN Pan invert Tilt Invert tit rtit Tilt invert Display Invert diS rdiS Invert the display DMX...

Страница 10: ...the master Master The master fixture may be set in any of the STANDALONE modes sound active fast or slow Slave 1 Press MODE ESC until NASL appears on the LED screen 2 Using UP and DOWN select SLAu 3...

Страница 11: ...The purpose of this menu is to adjust the home position electronic adjustment of the attributes listed below MAIN FUNCTION SELECTION INSTRUCTION P128 000 255 Adjustment for pan t128 000 255 Adjustment...

Страница 12: ...nction Pan tilt move in black Pan tilt move in black disable Color wheel move in black Color wheel move in black disabled Gobo wheel move in black Gobo wheel move in black disabled No Function All mov...

Страница 13: ...ow blue split colors Blue Kelly split colors Kelly red split colors Red dark blue split colors Dark blue white split colors Rotate clockwise slow fast Rotate counter clockwise slow fast 7 000 003 004...

Страница 14: ...it addressing Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interfa...

Страница 15: ...ast every 20 days Clean the fixture at least every 30 60 days Always dry the parts carefully after cleaning them Never spin a fan using compressed air Returns Procedure Returned merchandise must be se...

Страница 16: ...utput 4 units max LIGHT SOURCE Type high power single source LED Quantity 1 white Rating red green blue 60 W 14 9 A 50 000 hrs PHOTO OPTIC Lux 9 650 1 m Beam angle 21 INDOOR OUTDOOR Rating For indoor...

Страница 17: ...NW 108 th Ave Sunrise FL 33351 voice 954 929 1115 fax 954 929 5560 toll free 800 762 1084 Technical Support CHAUVET 5200 NW 108 th Ave Sunrise FL 33351 voice 954 929 1115 Press 4 fax 954 929 5560 Att...

Отзывы: