Page 9 of 17
Intimidator Scan LED 300 User Manual (Rev. 3)
4.
O
PERATING
I
NSTRUCTIONS
Using the Control Panel
Access control panel functions using the four buttons located directly underneath the LED display on the
included wired remote.
B
UTTON
F
UNCTION
<MODE
ESC>
Used to scroll through the current
operating mode, as well as back out of
the current menu option
<DOWN>
Used to select decreasing advancement
in the value
<UP>
Used to select increasing advancement
in the value
<ENTER>
Used to select a value and store it to
memory
Use the control panel to select the operating mode, as well as the sub-features. For a detailed layout of the
control panel functions, please see the “menu map” section on the previous page.
Menu Map
Menu
Programming Steps
Description
DMX Mode
d001
d001~512
DMX starting address
Standalone Mode
NASL
NASL
SLAu
SoN
Standalone: Slave receive mode
NStS
SrUn
Standalone: Slow
NAFA
FASt
Standalone: Sound-active
Pan Invert
PAN
rPAN
Pan invert
Tilt Invert
tit
rtit
Tilt invert
Display Invert
diS
rdiS
Invert the display
DMX Personality
11CH
8CH
8-channel DMX personality
11CH
11-channel DMX personality
Reset
rESt
Reset all motors to correct any errors with
motors misaligning during operation
Load Default
LoAd
Revert all settings back to the factory
default
Configuring the Starting Address
The Intimidator™ Scan LED 300
fixture uses up to
11
DMX channels. In this DMX configuration/personality,
the highest channel that the fixture may be set to in order to function properly is
502
. Any address higher
than this will prevent access to all of the channels, while in this mode; however, if you desire to use one of
the other DMX channels configurations (personalities), please consider the total DMX channels when
selecting a DMX address.
The Intimidator™ Scan LED 300 fixture uses
8 or 11
DMX channels, depending on the selected DMX
configuration (personality).