background image

 

DMX-150SQ User Manual 

2005-05-05/09:34

 

Optional Controller 

Daisy Chain 
Connection 

O

PERATING 

I

NSTRUCTIONS

 

Operating Modes 

The DMX-150SQ can be operated in three ways.   

 

A stand-alone mode will listen to sound and run through its diverse range of built in programs. An 
optional CH-X wired controller provides remote blackout control.  

 

Master/Slave mode will allow the command of up to as many units you want in a synchronized light 
show to the sound. 

 

DMX control mode will provide the greatest flexibility and creativity. Each fixture trait can be controlled 
individually using any universal DMX-512 controller.  

Stand Alone 

The Stand Alone mode is activated automatically when the fixture is absent of DMX signal or a 

controller is not connected. The DMX-150SQ will run through its built in programs as it listens to the 

sound. The optional CH-X wired controller also provides a blackout function.  

Master/Slave 

The Master/Slave mode will allow you to link up to as many units you want in a daisy chain fashion. In 

this mode, the first unit in the daisy chain will automatically command all other units following. An 

optional CH-X controller connected to the first unit in the chain will allow a blackout function. 

Connecting the DMX-150SQ for (Master/Slave) operation does not require any menu or setting 

selections. Simply connect each unit in a daisy like fashion using qualified 3 pin DMX cables as 

described below.  

Setting dipswitch # 10 to ON will invert the effect or mirror rotation in the fixture. 

M AS T E R/ S L AV E   S E T T I NG S  

1) 

Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector 
of the first fixture.  

2) 

Connect the end of the cable coming from the first fixture which will have a (female) 3 pin 
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, 
proceed to connect from the output as stated above to the input of the following fixture and so on 
as illustrated below.  

 

Note!  

For additional information on linking fixtures read under section 

DMX Primer

 

DMX Mode 

Operating in a DMX Control mode environment gives the user the greatest flexibility when it comes to 

customizing or creating a show.  In this mode you will be able to control each individual trait of the 

fixture independently.  

S E T T I NG T HE   ST ART I NG   ADDRE S S  

This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start 

address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data 

Содержание DMX-150SQ

Страница 1: ...Chauvet 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 05 05 09 34 DMX 150SQ DJ Squeeze II USER MANUAL ...

Страница 2: ...S 4 DMX CHANNEL SUMMARY 4 PRODUCT OVERVIEW 5 SETUP 6 LAMP 6 Lamp installation 6 POWER 6 MOUNTING 7 Orientation 7 Rigging 7 OPERATING INSTRUCTIONS 8 OPERATING MODES 8 Stand Alone 8 Master Slave 8 Master Slave settings 8 DMX Mode 8 Setting the starting address 8 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX CHANNEL VALUES 11 MAINTENANCE 11 RETURNS PROCEDURE 12 CLAIMS 12 GENERAL TROUBLESHOOTING 13...

Страница 3: ... future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rai...

Страница 4: ... effect rotation Features Manual focus Built in beat activated programs stand alone Master Slave mode Automatically enters stand alone when no DMX signal is present Squeeze Effect Bulb saver cuts off after 10 seconds of silence Blackout Micro Stepping Motors Fan cooled Thermal switch protection Options CH X Blackout Controller Programmable via any universal DMX 512 controller DMX Channel Summary C...

Страница 5: ...DMX 150SQ User Manual 5 2005 05 05 09 34 Product Overview Hanging Bracket Fan Power Fuse DMX Input Output Music Sensitivity Knob DMX 512 dipswitches Focusing Lens Lamp access Product Overview ...

Страница 6: ...ase 4 Detach the lamp from the lamp socket and replace 5 Replace lamp face plate align the screw holes and fasten the thumbscrews 6 No lamp alignment is necessary for this fixture since the lamp is already optimized inside the reflector Power Your product is equipped with switch selectable AC power setting Warning Verify that the power select switch on your unit matches the line voltage applied Al...

Страница 7: ...nts pathway Mount the fixture using a suitable C or O type clamp Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration lamp replacement access and routine maintenance Safety cables should always be used Never mount in places where the fixture will be expose...

Страница 8: ...ted to the first unit in the chain will allow a blackout function Connecting the DMX 150SQ for Master Slave operation does not require any menu or setting selections Simply connect each unit in a daisy like fashion using qualified 3 pin DMX cables as described below Setting dipswitch 10 to ON will invert the effect or mirror rotation in the fixture MASTER SLAVE SETTINGS 1 Connect the male 3 pin co...

Страница 9: ...he group of DIP switches located usually on bottom of the fixture Each dip switch has an associated value Adding the value of each switch in the ON position will provide the start address Determining which switches to toggle ON given a specific start address can be accomplished in the following manner By subtracting the largest switch value possible from the selected start address which does not c...

Страница 10: ...ne fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while p...

Страница 11: ...nical wear Be sure to power off fixture before conducting maintenance Unplug fixture from power Use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue Apply solution to the cloth or tissue an...

Страница 12: ...pping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandis...

Страница 13: ...sible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Motor movement...

Страница 14: ...14 male socket Current draw peak 257W 120V inrush 690W 120V LAMPS ELC3 300 hr 250W 24V THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 3A Fast Blow PCB 20mm Glass 2A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 4 ORDERING INFOR...

Отзывы: