background image

 

DMX-150SQ User Manual 

2005-05-05/09:34

 

B

EFORE 

Y

OU 

B

EGIN

 

What is included 

 

1 x DJ Squeeze

 

II (DMX-150SQ) 

 

Power cord with plug 

 

ELC3 250w lamp 

 

Warranty Card

Unpacking Instructions 

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that 

all parts are present, and have been received in good condition. Notify the shipper immediately and 

retain packing material for inspection if any parts appear damaged from shipping or the carton itself 

shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture 

must be returned to the factory, it is important that the fixture be returned in the original factory box 

and packing. 

AC Power 

To determine the power requirements for a particular fixture, see the label affixed to the back plate of 

the fixture or refer to the fixture

s spe

cifications chart. A fixture

s listed current rating is its average 

current draw under normal conditions. All fixtures must be powered directly off a switched circuit and 

cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer 

channel is used solely for a 0% to 100% switch. Before applying power to a 

fixture, check that the source voltage matches the fixture

s requirement. 

Check the fixture or device carefully to make sure that if a voltage selection 

switch exists that it is set to the correct line voltage you will use. 

Warning! 

Verify that the power select switch on your unit matches the 
line voltage applied. All fixtures must be connected to circuits 
with a suitable Earth Ground.  

Safety Instructions 

 

Please keep this User Guide for future consultation. If you 
sell the unit to another user, be sure that they also receive 
this instruction booklet. 

 

Always make sure that you are connecting to the proper 
voltage and that the line voltage you are connecting to is 
not higher than that stated on decal or rear panel of the 
fixture. 

 

This product is intended for indoor use only! 

 

To prevent risk of fire or shock, do not expose fixture to 
rain or moisture. Make sure there are no flammable 
materials close to the unit while operating. 

 

The unit must be installed in a location with adequate 
ventilation, at least 50cm from adjacent surfaces. Be sure 
that no ventilation slots are blocked. 

 

Always disconnect from power source before servicing or 
replacing lamp or fuse and be sure to replace with same 
lamp source. 

 

Secure fixture to fastening device using a safety chain. 
Never carry the fixture solely by its head. Use its carrying 
handles. 

 

Maximum ambient temperature is Ta: 40

°

. Do not operate 

fixture at temperatures higher than this.  

 

In the event of serious operating problem, stop using the 
unit immediately. Never try to repair the unit by yourself. 
Repairs carried out by unskilled people can lead to 
damage or malfunction. Please contact the nearest 
authorized technical assistance center. Always use the 
same type spare parts. 

 

Don

t connect the device to a dimmer pack.

 

 

Make sure power cord is never crimped or damaged. 

 

Never disconnect power cord by pulling or tugging on the 
cord. 

 

Avoid direct eye exposure to lamp while it is on.  

 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or 
attempt any repairs yourself. In the unlikely event your unit may require service, 
please contact CHAUVET. 

 

Figure 1 - AC Voltage Switch 

 

 

Please read these instructions carefully, which includes important 

information about the installation, usage and maintenance? 

 

 

Содержание DMX-150SQ

Страница 1: ...Chauvet 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 05 05 09 34 DMX 150SQ DJ Squeeze II USER MANUAL ...

Страница 2: ...S 4 DMX CHANNEL SUMMARY 4 PRODUCT OVERVIEW 5 SETUP 6 LAMP 6 Lamp installation 6 POWER 6 MOUNTING 7 Orientation 7 Rigging 7 OPERATING INSTRUCTIONS 8 OPERATING MODES 8 Stand Alone 8 Master Slave 8 Master Slave settings 8 DMX Mode 8 Setting the starting address 8 APPENDIX 10 DMX PRIMER 10 Fixture Linking 10 DMX CHANNEL VALUES 11 MAINTENANCE 11 RETURNS PROCEDURE 12 CLAIMS 12 GENERAL TROUBLESHOOTING 13...

Страница 3: ... future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rai...

Страница 4: ... effect rotation Features Manual focus Built in beat activated programs stand alone Master Slave mode Automatically enters stand alone when no DMX signal is present Squeeze Effect Bulb saver cuts off after 10 seconds of silence Blackout Micro Stepping Motors Fan cooled Thermal switch protection Options CH X Blackout Controller Programmable via any universal DMX 512 controller DMX Channel Summary C...

Страница 5: ...DMX 150SQ User Manual 5 2005 05 05 09 34 Product Overview Hanging Bracket Fan Power Fuse DMX Input Output Music Sensitivity Knob DMX 512 dipswitches Focusing Lens Lamp access Product Overview ...

Страница 6: ...ase 4 Detach the lamp from the lamp socket and replace 5 Replace lamp face plate align the screw holes and fasten the thumbscrews 6 No lamp alignment is necessary for this fixture since the lamp is already optimized inside the reflector Power Your product is equipped with switch selectable AC power setting Warning Verify that the power select switch on your unit matches the line voltage applied Al...

Страница 7: ...nts pathway Mount the fixture using a suitable C or O type clamp Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration lamp replacement access and routine maintenance Safety cables should always be used Never mount in places where the fixture will be expose...

Страница 8: ...ted to the first unit in the chain will allow a blackout function Connecting the DMX 150SQ for Master Slave operation does not require any menu or setting selections Simply connect each unit in a daisy like fashion using qualified 3 pin DMX cables as described below Setting dipswitch 10 to ON will invert the effect or mirror rotation in the fixture MASTER SLAVE SETTINGS 1 Connect the male 3 pin co...

Страница 9: ...he group of DIP switches located usually on bottom of the fixture Each dip switch has an associated value Adding the value of each switch in the ON position will provide the start address Determining which switches to toggle ON given a specific start address can be accomplished in the following manner By subtracting the largest switch value possible from the selected start address which does not c...

Страница 10: ...ne fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 while p...

Страница 11: ...nical wear Be sure to power off fixture before conducting maintenance Unplug fixture from power Use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue Apply solution to the cloth or tissue an...

Страница 12: ...pping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandis...

Страница 13: ...sible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Motor movement...

Страница 14: ...14 male socket Current draw peak 257W 120V inrush 690W 120V LAMPS ELC3 300 hr 250W 24V THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 3A Fast Blow PCB 20mm Glass 2A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 4 ORDERING INFOR...