OPTIFLEX S USER MANUAL 

6

PRODUCT DESCRIPTION

The OptiFlex

®

S is a continuous passive motion machine typically used

postoperatively on shoulder procedures. By repeatedly moving the affected joint in
the prescribed ranges of motion, the OptiFlex S lessens the adverse effects of
immobilization and trauma on the joint (see 

Indications

section, page 7).

OptiFlex S is a prescription device used under the supervision or by the order of a
physician or other licensed healthcare provider.

The OptiFlex S features include:

• Anatomically correct adjustment
• Physiological movement processes
• The greatest possible range of motion
• Hand-held pendant for precise setup of all treatment values
• OptiCard

for storing programmed values

• Easy-to-transport design

The OptiFlex S allows the following motions of the shoulder joint:

Abduction/Adduction

0°- 30° - 175°

Internal/External Rotation

90°- 0° - 90°

Elevation (Flexion) with 60° - 90° flexion of the elbow

0°- 30° - 175°

Ante/Retroversion (horizontal abduction/adduction) set manually

0° - 120°

OPTIFLEX S USER MANUAL 

Содержание Optiflex S

Страница 1: ...User Manual Problem Solving Through Innovation ...

Страница 2: ...ackage Contents 5 Product Description 6 Indications 7 Adjusting the OptiFlex S 8 Pendant Nomenclature 10 Programming the OptiFlex S 11 Converting the OptiFlex S 19 Transporting the OptiFlex S 20 Maintenance 20 Technical Specifications 21 Parts Description 22 Warranty 24 Replacement Parts List 26 OPTIFLEX S ...

Страница 3: ...if cord or plug is damaged Use extra care when touching metal of OptiFlex S after exposure to cold or heat DO NOT handle any electrical apparatus with wet hands DO NOT use OptiFlex S as a toy Condensation could result and damage OptiFlex S if unit is subjected to periods of low temperatures followed by periods of high temperatures DO NOT use on unstable surfaces Precautionary measures should be ta...

Страница 4: ...tting and programming interrupt therapy immediately Check the device and contact Chattanooga Group Customer Service if necessary The programming unit should be explained to the patient and must be located within the patient s reach usually in the storage area provided so therapy can be interrupted if necessary The OptiCard should be labeled with the patient s name and may only be used for this pat...

Страница 5: ... please read this manual thoroughly and become familiar with the controls as well as the accessories before operating the unit Specifications put forth in this manual were in effect at the time of publication However owing to Chattanooga Group s policy of continual improvement changes to these specifications may be made at any time without obligation on the part of Chattanooga Group PACKAGE CONTEN...

Страница 6: ... or by the order of a physician or other licensed healthcare provider The OptiFlex S features include Anatomically correct adjustment Physiological movement processes The greatest possible range of motion Hand held pendant for precise setup of all treatment values OptiCard for storing programmed values Easy to transport design The OptiFlex S allows the following motions of the shoulder joint Abduc...

Страница 7: ...ing hospital stays Clinical Indications OptiFlex S may benefit patients who have undergone Shoulder arthroplasty Revision total joint arthroplasty Manipulation of elbow or shoulder Synovectomies Fractures of radius ulna and humerus fixation Intra articular fractures of elbow or shoulder Abrasion arthroplasty of elbow or shoulder Osteotomies post fixation and healing Septic joints Allographs Acromi...

Страница 8: ...mber one through five see numbering on device Ante Retroversion Horizontal Abduction Adduction Figure A Ante retroversion is adjusted manually The aim of the adjustment is to find the most comfortable position for the patient Carry out this adjustment using the Adjustment Knob 11 Tighten the Adjustment Knob securely after adjustment Height Adjustment Figures B and C 1 Secure the arm support at the...

Страница 9: ...ent lift Motor B 20 slightly After correct adjustment is made tighten the wing screw 19 Setting the Lower Arm Length Figure G Open the Eccentric Lever 25 Pull out the hand support until the lower arm of the patient rests comfortably between it and the elbow support Close the Eccentric Lever 25 Adjusting the Backrest Figure H 1 Loosen the wing Screw 10 2 Push the backrest upright and tighten the wi...

Страница 10: ...OPTIFLEX S USER MANUAL 10 PENDANT NOMENCLATURE AB ADDUCTION ROTATION PAUSE MOTOR ON OFF SPEED TIMER LED DISPLAY STOP START SPECIAL FUNCTIONS SET OPTIFLEX S USER MANUAL ...

Страница 11: ...multaneously for one second or hold down the STOP button for five seconds to switch to programming mode 2 Select the treatment values in succession by pressing parameter buttons In the case of buttons with dual assignment press the buttons again in order to set the second treatment value 3 Use the buttons to change the relevant value You can run through the values quickly by holding down the or bu...

Страница 12: ...30 Abduction 175 Elevation flexion 30 175 Only to be used in isolation without rotation Set Motor B in 90 external rotation and switch off Internal Rotation 90 External Rotation 90 Manual Anteversion horizontal adduction 120 Retroversion horizontal abduction 0 CAUTION Recommended sequence for programming 1 Adduction 2 Internal Rotation 3 External Rotation 4 Abduction Unless otherwise prescribed by...

Страница 13: ... Make sure that at least one motor is always switched on If this is not the case the MOTOR A B OFF error code will appear on the LED display Setting the Timer 1 The settable values for the timer for therapy time are 1 300 minutes or Continuous 2 The device will stop at the midpoint of the treatment range automatically when the therapy time is complete 3 In Continuous mode the treatment is terminat...

Страница 14: ...ce Menu To program the Special Functions 1 Switch to Programming mode 2 Press the FUNC button 3 Select a special function using the or button 4 Follow the directions on the LED Display 5 Terminate with the STOP button New Patient When this special function is activated the OptiFlex S is reset to the factory setting All previously programmed values are deleted OPTIFLEX S USER MANUAL ...

Страница 15: ... Timer Continuous Mode Reverse on load set to Maximum 25 All special functions are deactivated Motors run synchronously 1 Press the FUNC button in Programming mode 2 Select the Factory Settings function with the or button 3 Activate the function with the SET button 4 Press the START button 5 The device enters the factory setting and stops automatically OPTIFLEX S USER MANUAL ...

Страница 16: ...gain treatment begins with the warm up mode unless it is deactivated Asynchronous Motors A and B can be operated synchronously or asynchronously In synchronous use Motors A and B execute a synchronous motion in terms of adduction internal rotation and abduction external rotation In asynchronous use the two motors operate independently in the relevant range of motion This mode requires particular c...

Страница 17: ...e special Reverse function by pressing the SET button 5 Select the next function with the or button or terminate programming Duration of Therapy The entire length of treatment for each patient can be called up under the Therapy Duration menu item 1 Select Therapy Duration function using the or button The length of therapy will be displayed 2 To clear Therapy Duration function hold down the SET but...

Страница 18: ...isplay between 0 100 To set this value press SET again Service Menu This is intended for certified service personnel only See service manual Save Data To save the programmed special functions press the STOP button CAUTION Before treatment a test run involving several movement cycles should be carried out first without and then with the patient OPTIFLEX S USER MANUAL ...

Страница 19: ...the seat 1a 4 Hold the arm support at the upper arm tube Loosen the wing screw pull out the arm support and insert it into the receiving tube on the opposite side Tighten the wing screw 1b 1c 5 Loosen the wing screw at the elbow joint and turn the lower armrest by 180 Tighten the wing screw 2 6 Hold the lower armrest and loosen the wing screw for the swivel mechanism Swivel the lower armrest aroun...

Страница 20: ...at room temperature If the unit is exposed to temperatures below freezing during transport the device MUST BE ALLOWED TO STAND AT ROOM TEMPERATURE FOR ABOUT TWO HOURS in order to avoid condensation The OptiFlex S can only be operated in dry rooms MAINTENANCE Always unplug the device before cleaning The OptiFlex S can be wiped clean with disinfectant and therefore complies with the required hygieni...

Страница 21: ...Protection Class VDE Class I Type B Transport Dimensions 23 H x 34 L x 23 W 58 H x 87 5 L x 57 5 W cm Adjustable Ranges Min Max High Setting 14 28 35 71cm Upper Arm Length 8 13 20 32cm Lower Arm Length 11 18 29 46 cm Seat Height 19 48cm Weight 55 lbs 25 kg MPG Class 2a CSA IEC 60601 1 1990 A1 1993 A2 1995 CSA 601 1 M90 UL Standard 2601 1 OPTIFLEX S USER MANUAL ...

Страница 22: ...ent 14 Internal tube for height adjustment 15 Motor A 16 Outer tube for adjusting the upper arm length 17 Eccentric lever for adjusting the upper arm length 18 Internal tube for adjusting the upper arm length 19 Wing screw for adjusting the elbow angle 20 Motor B 21 Elbow support 22 Lower arm support 23 Lower arm support belt 24 Outer tube for adjusting the lower arm length 25 Eccentric lever for ...

Страница 23: ...OPTIFLEX S USER MANUAL 23 2 OPTIFLEX S USER MANUAL 12 5 5 6 14 13 1 18 16 15 11 10 4 17 3 I In ns se et t o of f B Ba ac ck k 7 8 9 19 20 21 22 23 24 25 26 27 28 ...

Страница 24: ...aired Product to the consumer s facility All repairs must be performed by a service center authorized by Chattanooga Group Any modifications or repairs performed by unauthorized centers or groups will void this warranty To participate in warranty coverage this Product s warranty registration card included with Product must be filled out and returned to Chattanooga Group by the original owner withi...

Страница 25: ...TAIN SERVICE from Company or the selling dealer under this warranty the owner must do or abide by the following 1 A written claim must be made within the warranty period to the Company or the selling dealer If the claim is made to the Company written claim should be sent to 4717 Adams Road P O Box 489 Hixson TN 37343 USA Phone 423 870 7200 2 The Product must be returned to the Company or the selli...

Страница 26: ...r Arm Support 20671 1 Lower Arm Support Belt 20672 1 Elbow Support Pad 20673 2 Eccentric Lever Assembly 20674 4 Wing Screw 20675 1 Wing Nut 20676 1 Scale Left 20677 1 Scale Right 20678 1 Seat 20679 1 Backrest 20680 2 Wheel Assembly 20681 2 Tube Cap 20686 2 Rubber Glide 20687 1 OptiCard Holder OptiFlex S Accessories 20660 Patient Softgoods Kit 20661 OptiCard Chip cards 5 Pack 20664 OptiCard Pen ...

Страница 27: ...tc Myossage Massage Lotion Nylatex Elastic Wraps OptiFlex and OptiFlex S Continuous Passive Motion Opti Ice Cold Therapy System Para Care Paraffin Wax Unit Pillow Perfect Cervical Pillow Line Pivotal Therapy System Orthotics for the Spine PR and PR II Pressure Reduction Wheelchair Cushions ProPower Pillow Power Massage Pillow PresSsion Intermittent Compression Pron Pillo Positioning Pillow SensaFl...

Отзывы: