of the surround.
FLUE CONNECTION AND INFILLING
portland cement throughly mixed together. Enough water should be
added so that no more than one or two drops of water are released
Remove any excess fire cement from around the sealing flange.
when a handful of mixture is squeezed.
The appliance should be screwed to the hearth through the holes at
After filling with vermiculite flaunch the top of the flue connector
the base of the sealing flange.
pipe to the chimney with lime mortar. Ensure that the flue pipe is
well sealed to the chimney.
When connecting to a stainless steel flue liner (See Fig. 5),
150° Elbow with Welded Socket,
Part No. 010/AV37.
The legs
The socket is drilled to take 3 self tapping screws
of the elbow may be cut on site to suit the chimney. Also note that
to secure it to the flue liner.
the legs of the elbow are different lengths to enable some situations
to be catered for by turning the elbow around.
Make good hole(s) in the chimney breast making sure that it is
completely airtight. Typical installations are shown in Figs. 4 & 5.
The end of the flue pipe must line up with the centre-line of the
chimney, and must also extend to the point where the chimney
In most installations it will be possible to sweep the chimney through
narrows to its final size. Any large voids must be filled and flaunched
the appliance. If this is not possible then some alternative means
to the flue pipe to ensure that all soot deposits can be cleared when
(such as a soot door) must be provided.
the appliance is swept, and to prevent problems with the operation
The free inset method of installation may be used instead of infilling.
of the appliance.
Details are available on request.
Ensure that the flue pipe is not obstructed or restricted in any way
and that all joints are well sealed.
Before infilling cover the front of the appliance to protect it. Ensure
that the flue pipe is central and then fill the space between the body
The SLX20 may be installed as a Freestanding Stove when supplied
of the appliance and the structural brickwork with vermiculite (e.g.
with the Freestanding Panel Pack 020/XV30. Typical installations are
Micafil or similar) concrete. Ensure that there are no air pockets. The
shown in Figs. 6 & 7, and may be either on a freestanding hearth or
recommended mix is six volumes of vermiculite to one volume of
in an ‘Inglenook’ type fireplace. In these configurations the minimum
distances to combustible materials must be 250mm from the sides
of the stove and 700mm from the back. Stud wall is counted as
combustible, and if this distance is required to be reduced, then
additional shielding must be provided.
The Hearth requirements are the same as the Inset Installation.
If the stove is to be installed on a freestanding hearth, as shown in
Fig. 7, then the fireplace may be bricked up and filled with non-
combustible material, the chimney breast broken into higher up the
wall, and a sleeve inserted to take the Fluepipe. The angle between
the vertical and the sleeve/fluepipe must be not less than 135°. It is
advisable for the vertical section of the Fluepipe to be at least
600mm long. A soot door for debris clearance/ chimney sweeping
must be provided and this may be in the side or front of the chimney
breast, or outside.
make the
When connecting to a standard chimney (see Fig. 4), make the flue
flue connection with the special
connection with the special 150° elbow, Part No. 010/AV12. Please
Please note that this item is ordered separately
note that this item is ordered separately from the appliance.
from the appliance.
2. INSTALLATION AS A
FREESTANDING STOVE
®
charnwood
INSTALLATION INSTRUCTIONS
SLX
2 0
MULTI-FUEL
12
Vermiculite
Infill
150° Elbow with Welded Socket
Part No. 010/AV37
150mm(6") Class 1 Flue Liner
suitable for Solid Fuel.
Flue Liner Insulation
(see manufacturer’s instructions)
Fig. 5. Typical Inset Installation using Stainless Steel Flue Liner