background image

HEALTH AND SAFETY PRECAUTIONS

WARNING: Please take care when installing the appliance that the 
requirements of the Health and Safety at Work Act are met.

Some types of fire cement are caustic and should not be allowed to 
come into contact with the skin. In case of contact wash with 
plenty of water.

If there is a possibility of disturbing any asbestos in the course of 
installation then please use appropriate equipment.

There must not be an extractor fan in the same room as the 
appliance as this can cause the appliance to emit fumes into the 
room.

There must be an adequate air supply to the room in which the 
appliance is installed totalling at least 8 square cm. (1.2 square 
inches) to provide combustion air. This is particularly necessary if 
the room is double glazed.

BSEN 15287-1:2007 

This stove is capable of intermittent operation when burning 
Wood logs and continuous operation when burning Smokeless 
fuel.

This stove is not suitable for use in a shared flue system.

In addition to these instructions the requirements of BS.8303 and 
BSEN 15287-1:2007 must be fulfilled. Local Authority Bylaws and 
Building Regulations, including those referring to national and 
European Standards, regarding the installation of Solid Fuel burning 
appliances, flues and chimneys must also be observed.

CO ALARMS

Building regulations require that whenever a new or replacement 
fixed solid fuel or wood/biomass appliance is installed in a dwelling 
a carbon monoxide alarm must be fitted in the same room as the 
appliance. Further guidance on the installation of the carbon 
monoxide alarm is available in BS EN 50292:2002 and from the 
alarm manufacturer's instructions. Provision of an alarm must not 
be considered a substitute for either installing the appliance 
correctly or ensuring regular servicing and maintenance of the 
appliance and chimney system.

be 175mm (7 inches) or 200mm (8 inches) internal diameter or 
square with sides of 175mm or 200mm internally and MUST NOT 
BE LESS THAN 150mm (6 INCHES) INTERNAL DIAMETER OR 
150 x 150MM INTERNAL SQUARE.

If an existing chimney is to be used it must be swept and checked, 
it must be in good condition, free from cracks and blockages, and 
should not have a excessive cross sectional area (e.g. greater than 
250mm x 250mm). If you find that the chimney is in poor 
condition then expert advice should be sought regarding the 
necessity of having the chimney lined. If it found necessary to line 
the chimney then a lining suitable for Solid Fuel must be used. 

If there is no existing chimney then a prefabricated block chimney 
or a twin walled insulated stainless steel flue conforming to     

 can be used either internally or externally. 

These chimneys must be fitted in accordance with the 
manufacturers instructions and Building Regulations.

CHIMNEY

In order for the appliance to perform satisfactorily the chimney 
height must not be less than 4 metres measured from the outlet of 
the fire to the top of the chimney. The chimney should preferably 

SPECIFICATION

®

charnwood

INSTALLATION  INSTRUCTIONS

SLX

2 0

 

MULTI-FUEL

 

10

Fuel Type

Wood Logs

Smokeless Fuel

Output

5.8kW  (19,800Btu/h)

6.3kW  (21,500 Btu/h)

Flue Gas Temp

326°C

336°C

Flue Gas Mass Flow

5.0 g/s

5.1 g/s

Max Hearth Temp.

90°C

182°C

Re-fuelling Cycle

0.84 hr (50 min)

4.0 hr

CO @ 13% O

2

0.16%

0.18%

Min Distance to 

Combustible 

Materials

INSET

FREESTANDING

Side

100mm

250mm

Above (inset)/ Rear

300mm

700mm

Min Flue Draft

25Pa (0.1in wg)

Stove Weight

125kg                                         

Add-in Boiler 

Output

2.0 kW

Содержание SLX20

Страница 1: ...SLX20 MULTI FUEL Operating Installation Instructions charnwood ...

Страница 2: ......

Страница 3: ...p 9 INSTALLATION INSTRUCTIONS Health Safety Precautions 10 Chimney 10 Hearth Fire Surround 11 Preparation of the Fireplace Fitting the Fire 11 Hot Water System 13 Fitting the Optional Add In Boiler 13 Thermostat 14 Assembly 14 Pre Lighting Check 14 Commissioning 14 Dimensions 15 Parts Lists 16 Certification 17 4 sh Clearance 6 6 7 10 Specification 1 Installation as an Inset Stove 11 11 Flue Connec...

Страница 4: ... been designed to work with minimum effort If any operation such as riddling the grate or opening and closing the door begins to require extra force then the cause must be investigated and corrected to prevent damage being caused to the stove Remember that the stove will be hot and is made from hard material Ensure that you have good balance before operating the fire When using the fire in situati...

Страница 5: ...ning Movement of the grate from one position to the other is on the right shown in Fig 1 Use the control knob on the left to effected using the tool supplied The grate is put into the wood control the heat output from the fire and keep the airwash control position by moving the tool up until the tool is vertical The grate is slightly open most of the time to keep the glass clean It will not be put...

Страница 6: ...ontal and the 45 position several The throat plate and flue ways may be cleaned with a low fire still times as shown in Fig 2 burning Use the scraper tool to scrape any sooty deposits off the Caution when riddling the grate using solid fuel do not go beyond front of the plate until they drop into the fire the 45 position as this can cause the grate to jam More soot will be deposited on the throat ...

Страница 7: ...leaning any soot from within the fire replace the throat plate such as WD40 will also help to keep all internal parts working well and the front firebars Door Seals Different types of sweep s brushes are available to suit different For the fire to operate correctly it is important that the door seals flueways For standard brick chimneys a wire centre sweep s brush are in good condition Check that ...

Страница 8: ...urning the thermostat down It may c the air inlet damper is closed at the bottom left of the appliance sometimes be beneficial to also keep the doors slightly ajar whilst the see Fig 1 and that it is not prevented from closing completely by a fire becomes established This can also apply when re fuelling piece of ash b When re fuelling keep the fuel back a little from the front firebars d a suitabl...

Страница 9: ...larm in the same room as the appliance If the alarm sounds unexpectedly follow the instructions given under Warning Note above IF YOU NEED FURTHER HELP If you need further help with your Charnwood then your Installer will be able to provide the answers to most questions Your Local Charnwood Premier Dealer has a great deal of experience and will also be able to provide helpful advice Further help i...

Страница 10: ...larm manufacturer s instructions Provision of an alarm must not be considered a substitute for either installing the appliance correctly or ensuring regular servicing and maintenance of the appliance and chimney system be 175mm 7 inches or 200mm 8 inches internal diameter or square with sides of 175mm or 200mm internally and MUST NOT BE LESS THAN 150mm 6 INCHES INTERNAL DIAMETER OR 150 x 150MM INT...

Страница 11: ...chimney then a draught stabiliser should be fitted The SLX 20 is supplied with one of two panel packs that makes it either an Inset stove SLX20i or a Freestanding stove SLX20fs The following sections apply specifically to the Inset Installation The Freestanding installation is mentioned later The appliance must be installed on a fireproof hearth The positioning of the appliance and the size of the...

Страница 12: ...nce to protect it Ensure that the flue pipe is central and then fill the space between the body The SLX20 may be installed as a Freestanding Stove when supplied of the appliance and the structural brickwork with vermiculite e g with the Freestanding Panel Pack 020 XV30 Typical installations are Micafil or similar concrete Ensure that there are no air pockets The shown in Figs 6 7 and may be either...

Страница 13: ...mall amount through the hole in the register plate and will be sealed in position This is shown in Fig 7 A double feed indirect hot water storage cylinder to BS 1566 part 1 should be used in most situations unless the appliance is to be fitted in a soft water area in which case a direct hot water cylinder may be used provided that the boiler is stainless steel All pipework in the primary circuit m...

Страница 14: ...se of the appliance ASSEMBLY positioning the appliance in the fireplace if the fire surround is already fitted Before fitting the boiler remove the front firebars the side and back fire plates and the firebricks Knock out the knock outs for the boiler tappings on the appropriate side of the firebox Remove the backnuts and fibre washers from the boiler tappings and fit the boiler into the appliance...

Страница 15: ...her side charnwood SLX 20 DIMENSIONS SLX20 MULTI FUEL 15 152 395 258 Short Leg 294 398 152 279 283 Long Leg Offset Dimensions with 150 Fluepipe 010 AV12 Reversed 607 592 Height to top of Flue Elbow 439 86 Flue Centreline 86 142 363 589 506 467 Dimensions for Freestanding Model with 150 Flue Elbow 002 AV13 ...

Страница 16: ... S Hinge Pin Set 35 004 XV30 Brick Retainer 8 008 KV16 R H Door Handle 36 003 TV02 A R H Door Assembly 9 002 KV14 Door Catch Cam 37 003 TV01 A L H Door Assembly 10 008 KV13 L H Door Knob 38 012 XV12 Serial No Label 11 010 RW21 Ashpan Riddling Tool 42 002 AV13 150 Flue Elbow Freestanding Kit 12 012 FW34 Scraper Tool 43 010 XV29 Freestanding Panel Fixing Bracket 13 008 BW50 Thermostat Knob 44 005 KV...

Страница 17: ...NERGY EFFICIENCY MINIMUM DISTANCE TO COMBUSTIBLE MATERIALS SIDE ABOVE inset REAR A Division of A J Wells Sons Limited Registered in England No 03809371 11 charnwood Bishops Way Newport Isle of Wight PO30 5WS United Kingdom A J WELLS SONS LTD A J WELLS SONS LTD SLX20 MULTI FUEL XV080 CPD 2011 WOOD LOGS 0 16 326 C 5 8 75 7 INSET 100mm 300mm ANTHRACITE 0 18 336 C 6 3kW 72 1 FREESTANDING 250mm 700mm ...

Страница 18: ... charnwood NOTES SLX20 MULTI FUEL 18 ...

Страница 19: ......

Страница 20: ... r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM y o u r p re m i e r d e a l e r REF SLX20 06 13 Issue H ...

Отзывы: