Alternative Soot Door Positions
Metal Closure Plate
or ‘Register Plate’
With Soot Door
Masonry
Chimney
1
0
4
5
2
3
Fig. 7. Freestanding Installation with Chimney Connection in ‘Inglenook’ type Fireplace
Fig. 6. Freestanding Installation with Chimney Connection above the Fireplace
Alternative
positions for
Soot Door
for sweeping
and debris
clearance
Masonry Chimney
1
0
4
5
2
3
135°
Min
150mm(6") Fluepipe
sleeved through
chimney wall
Old fireplace
filled with non-
combustible material
and bricked up.
Metal Closure
Plate or
‘Register Plate’
Min 700mm from
combustible materials
Recommended min
vertical section 600mm(24")
If the stove is to be installed in an ‘Inglenook’ type Fireplace, then
there must be sufficient space around and above it for air to
circulate, and for access for servicing. This requires a minimum of
150mm each side and 300mm above. There must not be any
combustible materials within these distances. A steel ‘Register’ plate
will be fixed into the chimney, preferably at a height where the
chimney narrows down so as to avoid having a large air void above
the register plate. The fluepipe from the stove will protrude a small
amount through the hole in the register plate, and will be sealed in
position. This is shown in Fig. 7.
A double feed indirect hot water storage cylinder to BS:1566 part 1
should be used in most situations, unless the appliance is to be fitted
in a soft water area in which case a direct hot water cylinder may be
used provided that the boiler is stainless steel.
All pipework in the primary circuit must be 28mm diameter and the
flow pipe must rise continuously from the boiler to the open vent.
If an indirect cylinder is used then the primary circuit should be filled
with a suitable inhibitor to prevent the build up of scale and
corrosion.
FITTING THE OPTIONAL
HOT WATER SYSTEM
ADD-IN BOILER
The optional add-in boiler which may be fitted in the appliance has an
The boiler replaces the rear firebrick and is reversible so that the 1”
output sufficient for domestic hot water heating. If the boiler is fitted
B.S.P. male tappings may come on either the left or the right hand
then the room heating will be reduced.
side of the boiler.
The hot water system should be a gravity circuit and must be
The boiler tappings protrude from the sides of the appliance and it
correctly vented as shown in Fig. 8.
will therefore be necessary to fit the boiler into the appliance after
®
charnwood
INSTALLATION INSTRUCTIONS
SLX
2 0
MULTI-FUEL
13
Содержание SLX20
Страница 1: ...SLX20 MULTI FUEL Operating Installation Instructions charnwood ...
Страница 2: ......
Страница 18: ... charnwood NOTES SLX20 MULTI FUEL 18 ...
Страница 19: ......