OPERATING  INSTRUCTIONS

REDUCED  BURNING

For reduced burning the fire door must be closed.

When burning wood in areas that are not smoke controlled, load 
some large logs on the fire and allow to burn for half an hour before 
closing the air control (this will help to reduce tar deposits in the 
chimney). Some experimentation may be necessary to find the 
setting most suitable for the type of fuel being used and the draw on 
the chimney.

To revive the fire, empty the ashpan (if burning fuel other than 
wood), riddle the fire, and open the air control to maximum. When 
the fire is burning well load on more fuel as necessary and adjust the 
air control to the desired setting.

CLEANING AND MAINTENANCE

Cleaning

The stove is finished with a high temperature paint which will 
withstand the temperatures encountered in normal use. This may be 
cleaned with a damp lint-free cloth when the stove is cold. Should re-
painting become necessary, high temperature paints are available 
from your supplier or from stove shops.

Cleaning the Glass

Most deposits on the glass may be burnt off simply by running the 
fire at a fast rate for a few minutes. If it becomes necessary to clean 
the glass then open the door and allow it to cool. Clean the glass 
using a damp cloth and then wiping over with a dry cloth. Any 
stubborn deposits on the glass may be removed with a proprietary 
stove glass cleaner or ceramic hob cleaner. Do not use abrasive 
cleaners or pads as these can scratch the surface which will weaken 
the glass and cause premature failure.

When Not in Use

If the fire is going to be out of use for a long period (for instance in 
the summer) then to prevent condensation, and hence corrosion, 
the air control should be left fully open and the fire door left ajar. It 
is also advisable to sweep the chimney and clean out the fire. 
Spraying the inside of the door and firebox with a light oil, such as 
W D40, will also help to keep all internal parts working well. After 
long periods where the fire has been out of use, the chimney and 
appliance flueways should be cleaned before lighting.  

Door Seals

For the fire to operate correctly it is important that the door seals 
are in good condition. Check that they do not become worn or 
frayed and replace them when necessary.

When burning authorised smokeless fuel follow the same lighting 
process as shown in figures 4-7  but use small kindling at first and 
then 1.9kg of heavier section (25mm square section) wood to give a 
good firebed.

Once the heavier section wood has established flame, add the 
mineral fuel, shut the door and pull the slider fully out. Push the 
slider in to desired setting once the fire is established in the coal.

REFUELLING

Keep the firebox well filled but do not allow fuel to spill over the top 
of the fuel retainer.

Logs should be evenly distributed, filling the firebed to give the most 
pleasing flame pattern. The air control must be fully opened after 
refuelling until the flames are established above the fire. It is best to 
refuel on to a hot fire bed of ash. If at this point the fire starts to die, 
the door must be cracked open until the fire is revived. If the fire has 
started to die down before refuelling, then more kindling wood must 
be added, the air control opened fully and the door cracked open to 
re-establish the firebed 

before

 adding fresh fuel. This will avoid 

excessive smoke emission.

Care should be taken, especially when burning wood, that fuel does 
not project over the fuel retainer or damage to the glass may be 
caused when the door is closed. It can also cause blackening of the 
glass. Maximum filling height is such that logs cannot fall from the fire 
when the door is opened. In smoke control areas do not fill the 
stove above the level of the air holes in the back bricks, as 
overloading can cause excess smoke. Liquid fuels are not to be used 
on this appliance.

When relighting the stove, leave the ash on the base if burning 
wood, unless it is becoming too deep, in which case some of it may 
be removed. If burning solid fuel, clear the grate and empty the 
ashpan before relighting.

ASH CLEARANCE

The ashpan should be emptied regularly before it becomes too full. 
Never allow the ash to accumulate in the ashpan so that it comes in 
contact with the underside of the grate as this will seriously damage 
the grate bars. The ashpan is handled using the tool provided. Care 
should be taken to ensure that ash is cool before emptying it into 
plastic liners or bins.

To make ash removal easier there is a special Charnwood ash carrier 
available. This may be purchased from your supplier or, in case of 
difficulty, directly from Charnwood.

Содержание C-Four Insert

Страница 1: ...Operating Installation Instructions charnwood Insert ...

Страница 2: ......

Страница 3: ...aning 9 Chimney Sweeping 9 CO Alarm 9 Troubleshooting 10 If you need further help 10 INSTALLATION INSTRUCTIONS Health and Safety Precautions 11 Air Supply 11 CO Alarms 11 Specification 11 Chimney 12 Hearth and Fire Surround 12 Preparation of Fireplace 13 Fitting the Convection Casing Flue Pipe and Stove 14 Pre lighting Check 17 Commissioning 17 CAA and Smoke Control 17 Dimensions 18 Parts Lists 19...

Страница 4: ...cleaner Throat plate Take down once a month and clean Sweep sooty deposits into fire Ash pan Ash pan is removed using tool provided Empty ash pan before ash comes into contact with underside of grate Chimney Have chimney swept twice a year Chimney can be swept through stove Servicing Stove should be serviced by a professional at least once a year p9 MAINTENANCE AND CLEANING Air control p5 Throat p...

Страница 5: ...pray on or near the stove when it is alight There is a risk of explosion or flash ignition of the spray When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to prevent accidental contact with the stove The fireguard should be manufactured in accordance with BS 8423 2002 The stove is suitable for intermittent operation DOOR OPERATION The ...

Страница 6: ...production For a higher burning rate move the air control to the nominal output position or for low burning to the fully closed position When the fire is burning normally the air control gives enough airwash to keep the glass clean However it will not always be possible to keep the glass clean with the air control fully closed Pull handle in and out to riddle Fig 3 Riddling and setting the grate C...

Страница 7: ...ound the smaller logs load the stove with larger logs to the required fuel load Logs should be no more than 75mm in diameter and 300mm long Close the door Maintain the air control at maximum at this stage Once long flames appear over the fire reduce the air control to the nominal output setting Once the fire is well established with each log alight at the top the air setting can be reduced again d...

Страница 8: ...me worn or frayed and replace them when necessary When burning authorised smokeless fuel follow the same lighting process as shown in figures 4 7 but use small kindling at first and then 1 9kg of heavier section 25mm square section wood to give a good firebed Once the heavier section wood has established flame add the mineral fuel shut the door and pull the slider fully out Push the slider in to d...

Страница 9: ...e right or the left retaining flange on the side plates Raise the opposite side and slide so that the throat plate is central and supported by both side plates Slide back so that the recessed edge at the back of the underside rests neatly on the face of the back brick CHIMNEY SWEEPING The chimney should be swept at least twice a year It will generally be possible to sweep the chimney through the a...

Страница 10: ...ays should then be cleaned If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately After a chimney fire the chimney should be carefully examined for any damage Expert advice should be sought if necessary IF YOU NEED FURTHER HELP If you need further help with your Charnwood then your Installer will be able to provide the answers to most ...

Страница 11: ...ir supply ducting may be terminated in the room or the ducting connections on the stove can be removed from the inside and outside of the convection casing and the rear of the air box The blanking plate should also be removed from underneath the air box and fitted in the place of the ducting connections on rear of the convection casing This is so that air is taken from between the fire box and the...

Страница 12: ...tainless steel flue to BSEN 15287 1 2007 can be used either internally or externally These chimneys must be fitted in accordance with the manufacturers instructions and Building Regulations Min 405mm Max 430mm Min 555mm Max 565mm Min 380mm Single wall flue pipe is suitable for connecting the stove to the chimney but is not suitable for using for the complete chimney It is important that there is s...

Страница 13: ...ly can be taken from using an external air kit or directly from the convection casing The air supply kit can be fitted in the room or outside in accordance with the requirements in Air Supply section p11 The inlet grille must not constrict the airflow through the duct and it must be permanently open A semi rigid aluminium flexible duct of no less than 80mm diameter is used to bring the air to the ...

Страница 14: ...re the four self clinching studs are in the holes in the flue collar pointing downwards Slide the convection casing into position in the opening until the flue outlet lines up with the flue pipe Any excess air ducting still in the opening can be pulled out at the external termination point and trimmed to fit the grille selected Ensure that the air supply duct is not kinked during the fitting proce...

Страница 15: ...g the stove Follow the liner manufacture s recommendations regarding insulating the liner If for any reason it is not going to be possible to sweep the chimney through the appliance a soot door must be fitted 6 SLIDE IN STOVE Carefully slide the stove into the convection casing until the flue outlet lines up with the flue collar and the air inlet engages at the rear of the stove 15 A B 7 INSERTCOA...

Страница 16: ...h the holes Secure bolts with nuts All flue connections must be well sealed Check that the flue pipe is not obstructed or restricted in any way and that all joints are well sealed Secure with nut here Sealed with 8mm self adhesive fibreglass webbing seal Upper flue collar Convection casing Flue pipe Wall of stove Inner flue collar SIDE PIECES Remove air control knob undo both allen key bolts in lo...

Страница 17: ...se them on the use of the appliance If the spillage test fails the cause must be found and rectified or the appliance decommissioned and the customer instructed not to use the appliance until it can be shown to operate safely CAA AND SMOKE CONTROL The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority ...

Страница 18: ... C FOUR I DIMENSIONS mm 18 485 595 380 ø127 for 5 flue 400 555 115 550 75 200 FRONT VIEW BACK VIEW SIDE VIEW PLAN VIEW 310 ø77 265 595 ...

Страница 19: ...y Brass Washer 28 002 BR012 Handle Casting 29 002 BR087 Handle Casting 30 004 BR014 Handle Pivot Pin 31 008 FFW015 Thackery Washer 32 008 FFB007 M8x100 Allen Hd Bolt 33 008 BR013 Wooden Handle Item Part No Description 34 010 TR020 Air Box Cover Plate 35 004 GR086 Air Control Rod 36 008 TR047 DEFRA Stop 37 008 AY37 Air Control Knob 38 008 BR052 Felt Washer 39 004 TR007 Air Inlet Slide 40 010 CR005 ...

Страница 20: ......

Страница 21: ...ustible materials Casing Side Casing Rear EN13229 2001 A2 2004 AC 2007 ROOMHEATERS FIRED BY SOLID FUEL 0 08 0 18 279 C 282 C 5 kW 4 9kW 80 77 3 Emission of CO in combustion products Flue gas temperature Space heating thermal output Energy efficiency Front surround side Front surround above Room in front of glass C Four I 100mm 130mm insulation 100mm 130mm insulation 280mm 310mm 1000 mm TR CPD 2014...

Страница 22: ...i t e d R e g i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM T 4 4 0 1 9 8 3 5 3 7 7 7 7 F 4 4 0 1 9 8 3 5 3 7 7 8 8 W W W C H A R N W O O D C O M y o u r p re m i e r d e a l e r ...

Отзывы: