11.
Set
Used for setting system parameters, screen as show below.
Figure.
11-1
(1)
Vacuum detection:
Click to open or close vacuum detection, note, if close
vacuum detection here, machine will not detect lack of material, also will not
discard material due to vacuum insufficient;
(2)
Vision assist:
Click to open or close vision auxiliary, if closed then all of
component are mounted without calibration by vision;
(3)
Visual lack detect
:
Click to open or close visual lack detect,if open
,
When the
material is attached to the detection of the lack of material will be re drawn, many
times to detect the lack of material, alarm and stops (if the visual detection error,
can be closed this function);
(4)
Z Axis detect
:
Click to open or close Z axis detect,if open
,
The Z axis is found to
be lost when the stick is attached, then the Z axis is automatically returned to the
origin.
。
This feature can be avoided due to the high level of the device is not set up
to cause the Z axis, damage to the device parts;
(5)
Run Speed:
Setting entire running speed of machine;
(6)
System set:
Setting advanced parameters, it‟s need code to enter;
(7)
Date time set:
Setting system time;