– 13 –
5.0 Filter Replacement Procedure
The standard tubing connections on the
Charger HydroSplash
are of Quick Connect
O-ring seal design and manufacture. Use the tubing and follow the instructions in
Figure 8 to make the connections. If you cut the tubing, make sure it is a square cut
and that the tubing fits evenly in the fitting and seals properly. Turn off the feed water at
the feed water ball valve. Turn the storage tank ball valve to the off position and open
the faucet. This will depressurize the system. Put a shallow pan under the RO system to
catch any water that may spill during the operation.
Unscrew filter body (1/4 turn counter clockwise), pull down, and carefully lift it to the
sink to drain the remaining water. Discard spent filter body. To install new filter body
remove red cap from cartridge, lubricate both o-rings on filter stem using common
cooking oil or Vaseline then insert it into the head and turn 1/4 turn clockwise. Repeat
operation for all 3 pre-filters (for 4-stage system, only 2 pre-filters) and one post-filter.
6.0 Conditions Of Use
Water must be microbiologically safe. System pressure, 40 to 100 PSIG. Temperature,
40 to 100°F. pH range, 3 to 10. Maximum TDS, 1500 PPM. Maximum Iron (FE) 0.3ppm,
Maximum Manganese (Mn) .0.1ppm, Turbidity, less than 1.0 NTU.
7.0 Installation Troubleshooting
Problem
Possible Cause
Solution
• No or low water production.
• Feed water shut off.
• Tank valve closed or partially
closed.
• Low feed pressure.
Feed pressure must by at
least 40 psi.
• Turn on feed water.
• Open tank valve.
• Increase inlet water pressure
or install booster pump if feed
water pressure is less than
40 psi.
• Leak at filter housing.
• Defective or misaligned
O-ring.
• Shut off feed valve and tank
valve. Turn on faucet. Change
or realign O-ring.
• Leak at tube connection.
• Not properly installed.
• Tighten compression fitting
• Remove tube and re-install
into fitting.
• Bad-tasting water.
• Post-filter cartridge not
flushed completely.
• Flush one or two tanks of
pure water through system.
• Water runs to drain all the
time.
• Auto-valve not closing
properly.
• Check valve not functioning
properly
• Purge the system again.
• Clean or replace check
valve
• RO Production good at
first but falls off in months or
weeks.
• High TDS and/or Iron and
Manganese.
• Consult your dealer or
Factory and provide water
analysis.
Содержание HydroSplash CWISO475CHPL