29
USER Section
(en)
7698967.01 (1-01/18)
2. PROLONGED SHUTDOWN. ANTI-FREEZE PROTECTION
Do not drain the whole system as filling up with water again could cause unnecessary and harmful scale to build up inside the
boiler and the heating elements. If the boiler is not used during winter and is therefore exposed to the danger of frost, add some
specific anti-freeze to the water in the system (e.g.: propylene glycol coupled with corrosion and scale inhibitors). The electronic
boiler management system includes a “frost protection” function for the heating system which, when delivery temperature falls
below 5°C, lights the burner until a delivery temperature of 30°C is reached.
The function is operative if: the boiler is electrically powered, there is gas, system pressure is normal and the boiler is not
blocked.
3. GAS CONVERSION
The boilers can operate both on natural gas (G20) and LPG (G31)
.
All gas conversions must be made by the AUTHORISED
TECHNICAL SERVICE CENTRE.
4. FAULTS
The faults shown on the display are identified with the symbol
and a number (fault code). For a
complete list of faults, see the following table.
If appears on the display the fault must be RESET by the user.
To RESET the boiler, press and hold down
for 2 seconds. If faults are displayed frequently, call the
Authorised Service Centre.
FAULTS TABLE
Description of fault
Description of fault
10
External probe sensor
125
No circulation safety trip
(control performed via a temperature sensor)
20
NTC flow sensor
128
No flame
28
NTC fumes sensor
130
Fumes NTC tripped due to overtemperature
40
NTC return sensor
133
Ignition failure (4 attempts)
50
NTC DHW sensor
(only for heating-only model with storage boiler)
151
Boiler board internal fault
52
Solar DHW sensor (if connected to a solar plant)
152
Generic parameter setting error
73
Solar manifold sensor (if connected to a solar plant)
153
Forced reset when the Reset button is pressed and held
for more than 10 seconds (see section “FAULTS THAT
CANNOT BE RESET BY THE USER”)
83
Communication problem between boiler board and control unit.
Probable short circuit on wiring.
160
Fan fault
84
Address conflict between control units
(internal fault)
321
NTC domestic hot water sensor faulty
98
Accessory not detected or recognized (*)
343
Generic parameter setting error of solar plant
(if connected to a solar plant)
109
Air in boiler circuit (temporary fault)
384
Abnormal light (parasite flame – internal fault)
110
Safety thermostat tripped due to overtemperature.
(pump blocked or air in heating circuit)
385
Input voltage too low
111
Safety thermostat tripped due to overtemperature.
386
Fan speed threshold not reached
117
Pressure in hydraulic circuit too high
430
No circulation safety trip
(control performed via a pressure sensor)
118
Pressure in hydraulic circuit too low
432
No functional earth or safety thermostat tripped due to over
temperature (E110)
(*)
After powering up the boiler (or after a Reset for lockout), the error appears on the display once the self-check is completed. The fault code
is displayed permanently if the accessory is not recognized.
In the event of a fault, the display backlighting indicates the error code. 5 reset attempts can be performed after which the
boiler shuts down. Wait 15 minutes before attempting to reset the boiler again.