11.2 ACCESSORIES NOT INCLUDED IN THE SUPPLY
11.2.1 REMOTE CONTROL
The wire (1) from the boiler terminal block M2 powers the display backlighting (12 V). It is not necessary to connect this wire to
make the Remote Control work.
To operate the boiler with the Remote Control mounted on the wall, purchase accessory
A
supplied with the base
A1
. Also see
the mounting and operation instructions supplied with the kit
A
. Proceed as follows:
• Switch off the boiler.
• Pass the three wires from the boiler terminal block
M2
through the hole in the base
A1
to apply to the wall.
• Connect wires
1-2-3
of the boiler terminal block
M2
to terminals
(1)-(2)-(3)
of the base terminal block
A1
respectively.
• Fix the base
A1
to the wall using the expansion grips and screws supplied with the accessory.
• Apply the Control Panel
A
to the base fixed to the wall, taking care not to apply excessive force.
• Power the boiler making sure that the Remote Control lights up.
A1
A
A - A1
A
A1
A1
A
B
B1
B
B1
A
Control Panel
A1
Base for wall-mounted Control Panel
B
Led interface accessory
B1
Base for Led interface accessory
(1)
Display backli12V
(2)
Earth connection
(3)
Power input/12V
Use the Remote Control to set the programmable timer for heating and DHW. See the instructions supplied with the accessory.
SETTING PARAMETERS USING THE REMOTE CONTROL
SYMBOLS FOR REMOTE CONTROL
Turn knob
B
Display shows
Press knob
B
Press button
A
and knob
B
together
Press button
A
or
C
Press buttons
A
and
C
together
KEY TO FIGURE MENU
1
Enduser
3
Engineer
2
Commissioning
4
OEM
The following procedure is used to access the four boiler
programming menus:
• from the main menu
C
.
•
A
and
C
(hold down for approx. 6 seconds)
B
menu
1
-
2
-
3
-
4
(see figure to side and key).
•
C
to go back one menu at a time to the main menu.
When the Control Panel is wall-mounted enable the
room
sensor
and
flow temperature modulation
as follows:
A) ROOM SENSOR
• Access menu
2
.
•
B
Operator unit
B
to confirm.
•
B
programme row
40
(Used as)
B
.
•
B
(anti-clockwise)
Room unit 1
B
to confirm (the room sensor is now active).