Maintenance
Rev 71000i-20100401 E
13
Maintenance
The owner/operator is responsible for all
periodic maintenance.
WARNING
Never operate a damaged or defective generator.
WARNING
Tampering with the factory set throttle control
will void your warranty.
WARNING
Improper maintenance will void your warranty.
Complete all scheduled maintenance in a
timely manner. Correct any issue before
operating the generator.
NOTE
For service or parts assistance, contact our help
line at 1-877-338-0999.
Engine Maintenance
To prevent accidental starting, remove and
ground spark plug wire before performing
any service.
Oil
Change oil when the engine is warm. Refer
to the oil specification to select the proper
grade of oil for your operating environment.
1.
Loosen the cover screw and remove the
maintenance cover.
2.
Remove the oil filler cap.
3.
Tilt the generator on its side and allow
the oil to drain completely.
4.
Add 0.26 qt (0.25 L) of oil and replace
oil fill cap/dipstick.
5.
Reinstall the maintenance cover and
tighten the cover screw.
6.
Dispose of used oil at an approved waste
management facility.
Spark Plugs
1.
Remove the spark plug maintenance
cover.
2.
Remove the spark plug cable from the
spark plug.
3.
Use the spark plug tool that shipped
with your generator to remove the plug.
4.
Inspect the electrode on the plug. It
must be clean and not worn to produce
the spark required for ignition.
5.
Make certain the spark plug gap is 0.6 -
0.7 mm (0.024 - 0.028 in.).
6.
Refer to the spark plug recommendation
chart when replacing the plug.
7.
Carefully thread the plug into the
engine.
8.
Use the spark plug tool to firmly install
the plug.
9.
Attach the spark plug wire to the plug.
10.
Reinstall the spark plug maintenance
cover.
Содержание 71000i