background image

Safety Rules 

 

Rev 71000i-20100401 E

 

 DANGER 

Fuel and fuel vapors are highly flammable and 
extremely explosive. 

Fire or explosion can cause severe burns or 
death.  

Unintentional startup can result in entanglement, 
traumatic amputation or laceration.  

When adding or removing fuel 

Turn the generator off and let it cool for at least 
two minutes before removing the fuel cap. 
Loosen the cap slowly to relieve pressure in the 
tank. 
Only fill or drain fuel outdoors in a well-ventilated 
area. 
DO NOT overfill the fuel tank. 
Always keep fuel away from sparks, open flames, 
pilot lights, heat and other sources of ignition. 
DO NOT light or smoke cigarettes. 

When starting the generator 

DO NOT attempt to start a damaged generator.  
Make certain that the gas cap, air filter, spark 
plug, fuel lines and exhaust system are properly 
in place. 
Allow spilled fuel to evaporate fully before 
attempting to start the engine. 
Make certain that the generator is resting firmly 
on level ground. 

When operating the generator: 

DO NOT move or tip the generator during 
operation. 
DO NOT tip the generator or allow fuel or oil to 
spill. 

When transporting or servicing the 

generator: 

Make certain that the fuel shutoff valve is in the 
off position and the fuel tank is empty. 
Disconnect the spark plug wire. 

When storing the generator: 

Store away from sparks, open flames, pilot lights, 
heat and other sources of ignition. 

 

 
 

 WARNING 

Rapid retraction of the starter cord will pull hand 
and arm towards the engine faster than you can 
let go. 

Unintentional startup can result in entanglement, 
traumatic amputation or laceration.  

Broken bones, fractures, bruises or sprains could 
result. 

When starting engine, pull the starter cord slowly 
until resistance is felt and then pull rapidly to 
avoid kickback. 
DO NOT start or stop the engine with electrical 
devices plugged in. 

 

 CAUTION 

Exceeding the generator’s running capacity can 
damage the generator and/or electrical devices 
connected to it 

DO NOT overload the generator. 
Start the generator and allow the engine to 
stabilize before connecting electrical loads. 
Connect electrical equipment in the off position, 
and then turn them on for operation.

 

Turn electrical equipment off and disconnect 
before stopping the generator.

 

DO NOT tamper with the governed speed. 

 

DO NOT modify the generator in any way.

 

 

 CAUTION  

Improper treatment or use of the generator can 
damage it, shorten its life and void your 
warranty. 

Use the generator only for intended uses.

 

Operate only on level surfaces.

 

DO NOT expose generator to excessive moisture, 
dust, or dirt.

 

DO NOT allow any material to block the cooling 
slots.

 

If connected devices overheat, turn them off and 
disconnect them from the generator.

 

DO NOT use the generator if:

 

 

Electrical output is lost

 

 

Equipment sparks, smokes or emits flames

 

 

Equipment vibrates excessively

 

 

Содержание 71000i

Страница 1: ...71000i Rev 71000i 20100401 10006 Santa Fe Springs Road Santa Fe Springs CA 90670 USA Made in China 1000W Max Power 900W Rated Power PORTABLE GENERATOR Owner s Manual and Operating Instructions...

Страница 2: ......

Страница 3: ...12 Maintenance 13 Engine Maintenance 13 Oil 13 Spark Plugs 13 Air Filter 14 Cleaning 14 Adjustments 14 Maintenance Schedule 14 Generator Maintenance 14 Storage 15 Specifications 16 Engine Specificati...

Страница 4: ......

Страница 5: ...wer Equipment manufactures and sells accessories designed to help you get the most from your purchase To find out more about our covers power cables and storm kits please visit our web site at www cha...

Страница 6: ...imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or ser...

Страница 7: ...tating parts Tie up long hair and remove jewelry Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught DANGER Generator produ...

Страница 8: ...re away from sparks open flames pilot lights heat and other sources of ignition WARNING Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go Uninte...

Страница 9: ...and features Save this manual for future reference Generator 1 Fuel Lever Vent Turn this valve to the On position to supply air to the tank 2 Fuel Cap Remove to add fuel 3 Power Panel See Power Panel...

Страница 10: ...ght turns ON when the generator is overloaded and will cut power to the receptacles 4 Low Oil Indicator Light red Check oil level when this light turns on Engine will not run when indicator is lit 5 1...

Страница 11: ...nd Features Rev 71000i 20100401 E 7 Parts Included Your 71000i Gasoline Powered Inverter Generator ships with the following parts Spark Plug Socket Assembly 1 set Oil Container 1 piece DC Accessory Co...

Страница 12: ...o crank or start the engine before it has been properly filled with the recommended type and amount of oil Damage to the generator as a result of failure to follow these instructions will void your wa...

Страница 13: ...l fuel tank indoors DO NOT fill fuel tank when the engine is running or hot DO NOT overfill the fuel tank DO NOT light cigarettes or smoke when filling the fuel tank Grounding Your generator must be p...

Страница 14: ...ly 7 As engine warms up move the choke lever to Run NOTE If the engine starts but does not run make certain that the generator is on a flat level surface The engine is equipped with a low oil sensor t...

Страница 15: ...riven equipment Following the steps listed under Power Management will guarantee that only one device will be starting at a time Power Management Use the following formula to convert voltage and amper...

Страница 16: ...HP 2000 4000 Water Heater 4000 Security System 180 AM FM Radio 300 Garage Door Opener 1 2 HP 500 600 Battery Charger 12V DC 110 Heating Cooling Air Conditioner 12000 BTU 1700 2500 Fan 300 600 Furnace...

Страница 17: ...cover screw and remove the maintenance cover 2 Remove the oil filler cap 3 Tilt the generator on its side and allow the oil to drain completely 4 Add 0 26 qt 0 25 L of oil and replace oil fill cap di...

Страница 18: ...remove dirt and oil Use an air compressor 25 PSI to clear dirt and debris from the generator Adjustments The air fuel mixture is not adjustable Tampering with the throttle control can damage your gene...

Страница 19: ...ntenance cover Drain all fuel completely from the fuel line and carburetor to prevent varnish build up Turn the engine switch fuel valve ON loosen the carburetor drain screw and drain the gasoline int...

Страница 20: ...Height 15 55 inches 39 5 cm Width 9 76 inches 24 8 cm Length 18 11 inches 46 cm Fuel Fuel capacity is 0 68 gallons 2 6 L Use regular unleaded gasoline with a minimum octane rating of 85 Oil Oil capaci...

Страница 21: ...Specifications Rev 71000i 20100401 E 17 Parts Diagram...

Страница 22: ...ss Plug Self Tapping Screw ST3 8X16 C H 6 25 KGE1000Ti 07300 Fuel Switch Assembly 1 26 KGE1000Ti b 07002 Fuel Pipe 1 27 KD M 10 A 02100 Stator assembly 1 28 KGE1000Ti 07007 Clip 9 3 29 GB T97 1 2002 W...

Страница 23: ...T818 2000 Screw M5X16 4 62 GB T97 1 85 Gasket 5 5 63 KD10 02000 KD10 Magnetoelectric Machine 1 64 GB T818 2000 H Type Cross Plug Screw M5X20 1 65 WZ Z2 a DC Receptacle DC12V 5A 1 66 RF 1003 BB2 Thrott...

Страница 24: ...Specifications 20 Rev 71000i 20100401 E Wiring Diagram...

Страница 25: ...to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventil...

Страница 26: ...ole Installation Use and Maintenance This warranty will not apply to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the gene...

Страница 27: ...Notes Rev 71000i 20100401 E 23 Notes...