Power Panel

(1)  Fuel Valve Knob 
(2)  Push-Button Choke 
(3)  Economy Control Switch
(4)  Wireless Set Button
(5)  Red Pilot Lamp
(6)  Ground Terminal

 – Consult an electrician for local 

grounding regulations.

(7)  12V DC Outlet*
(8)  Circuit Breaker (Push-button)

 – Protects the 

generator against electrical overload. 

(9)  Parallel Outlets 

– used for parallel operation. 

(10)  120 Volt AC, 20 Amp Duplex

 (NEMA 5-20R) – 

May be used to supply electrical power for the 
operation of 120 Volt AC, 20 Amp, single phase 
60 Hz electrical loads.

CONTROLS AND FEATURES

16

12

11

3

4

6

7

10

2

1

(11)  Battery Switch
(12)  120 Volt AC, 30 Amp Receptacle

 (NEMA TT-30R) 

– 

May be used to supply electrical power for the 

operation of 120 Volt AC, 30 Amp, single phase 
60 Hz electrical loads.

(13)  Oil Warning Light

 – Check oil level when this light 

turns on. Engine will not run when indicator is lit.

(14)  Overload Indicator Light

 – This light turns ON 

when the generator is overloaded and will cut 
power to the receptacles.

(15)  Output Light

 – Remains ON during normal 

operating conditions. Shuts OFF when generator is 
overloaded.

(16)  Ignition Switch

*Warning: Do not operate a device while it is plugged into 
the 12V DC outlet. Prolonged exposure to engine exhaust 
can cause serious injury or death. While charging a device 
do no place on the exhaust side of the generator. Extreme 
heat caused by exhaust can damage the device, and cause a 
potential fire hazard.

8

9

15

13

14

5

8

Содержание 100261

Страница 1: ...RATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV 100261 20181227 3400 Starting watts 3100 Running watts Wireless remote electric start OWNER S MANUAL OPERATING INSTRUCTIONS 100261 MODEL NUMBER A D A T I M I L A Í T N A R A G L I M I TED WARRAN T Y Y EAR AÑO 3 ...

Страница 2: ...s no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the eq...

Страница 3: ...e Start 14 Economy Control Switch 14 Connecting Electrical Loads 15 12V DC Outlet 15 Stopping the Engine 15 Do Not Overload Generator 16 Capacity 16 Power Management 16 Overload Operation 16 Operation at High Altitude 16 Wireless Set Button 17 Parallel Operation 17 Maintenance and Storage 18 Engine Maintenance 18 Oil 18 Spark Plugs 18 Air Filter 19 Cleaning 19 Spark Arrester Cleaning 19 Adjustment...

Страница 4: ... ensure the accuracy and completeness of the information in this manual and we reserve the right to change alter and or improve the product and this document at any time without prior notice Since CPE CET highly value how our products are designed manufactured operated and are serviced and also highly value your safety and the safety of others we would like you to take the time to review this prod...

Страница 5: ...us situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage CAUTION DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury DANGER WARNING indicates a potentially hazardous situation w...

Страница 6: ...generator Use a ground fault circuit interrupter GFCI in damp areas and areas containing conductive material such as metal decking Use approved transfer equipment to isolate generator from your electric utility and notify your utility company before connecting your generator to your power system DANGER Sparks can result in fire or electrical shock When servicing the generator Disconnect the spark ...

Страница 7: ... speed DO NOT modify the generator in any way CAUTION Cancer and Reproductive Harm www P65Warnings ca gov WARNING Fuel and fuel vapours are highly flammable and extremely explosive Fire or explosion can cause severe burns or death Unintentional startup can result in entanglement traumatic amputation or laceration When adding or removing fuel Turn the generator off and let it cool for at least two ...

Страница 8: ...el 2 Recoil Starter Used to start the engine 3 Power Panel 4 Foldaway Handle Do not use the foldaway handle to lift or carry the unit 5 Muffler 6 Carrying Handle 7 Maintenance Cover 8 Never Flat Wheels 9 Battery Access Cover Generator CONTROLS AND FEATURES Parts Included Your 100261 gasoline powered generator ships with the following parts Dual 2 4A Port USB Adapter 1 Oil funnel 1 Remote 1 637 637...

Страница 9: ...acle NEMA TT 30R May be used to supply electrical power for the operation of 120 Volt AC 30 Amp single phase 60 Hz electrical loads 13 Oil Warning Light Check oil level when this light turns on Engine will not run when indicator is lit 14 Overload Indicator Light This light turns ON when the generator is overloaded and will cut power to the receptacles 15 Output Light Remains ON during normal oper...

Страница 10: ... off fuel supply and stop engine immediately Allow to cool at least 2 minutes before refueling Lea y acate las instrucciones de operación antes de encender el motor La gasolina y el gas propano GLP son extremadamente inflamables Verifique si hay combustible derramado o fugas de combustible Si una es encontrada apague el suministro y pare el motor inmediatamente Permita que se enfrié por los menos ...

Страница 11: ...M controls the Auto Choke during each attempt to start If the generator does not start call Champion Customer Care team for assistance at 1 877 338 0999 To stop the generator by Remote Control press the STOP button on the Remote one time Remote Control Power Consumption While the Ignition Switch is in the ON position the RCM is active and waiting for a remote signal This function requires electric...

Страница 12: ...r remove the two 2 maintenance cover screws from the battery maintenance cover A 2 Once the screws have been removed the rubber pull tab on the cover can be pulled out to help loosen and dislodge the maintenance cover A 3 Remove the battery maintenance cover A If the battery cables are not visible once the battery maintenance cover has been removed please note that cables may be tucked up above th...

Страница 13: ...vals NOTE The generator rotor has a sealed pre lubricated ball bearing that requires no additional lubrication for the life of the bearing NOTE Full Synthetic 5W 30 Degrees Celsiusº Outside Outside Degrees Fahrenheitº Synthetic oil may be used after the 5 hour initial break in period Using synthetic oil does not increase the recommended oil change interval NOTE We consider the first 5 hours of run...

Страница 14: ...se regular unleaded gasoline with a minimum octane rating of 85 Do not mix oil and gasoline Fill tank to approximately 1 4 in 6 4 mm below the top of the tank to allow for fuel expansion DO NOT pump gas directly into the generator at the gas station Use an approved container to transfer the fuel to the generator DO NOT fill fuel tank indoors DO NOT fill fuel tank when the engine is running or hot ...

Страница 15: ... wet could result in electrocution WARNING WARNING During operation the muffler and exhaust fumes produced will become hot If adequate cooling and breathing space are not supplied or if the generator is blocked or contained temperatures can become extremely heated and may lead to fire Grounding The generator system ground connects the frame to the ground terminals on the power panel The generator ...

Страница 16: ...will prevent the engine from running when the oil level falls below a critical threshold NOTE Keep choke button in Choke position for only 1 pull of the recoil starter After first pull push choke button to the Run position for up to the next 3 pulls of the recoil starter Too much choke leads to spark plug fouling engine flooding due to the lack of incoming air This will cause the engine not to sta...

Страница 17: ...e the maintenance cover A For periods of high electrical load or momentary fluctuations the Economy Control Switch should be turned OFF WARNING Manual Choke Start Cont d OPERATION Manual Choke Start 2 Locate the yellow manual choke lever B 3 Turn the choke lever to the CHOKE right position B 4 Turn the fuel valve to the ON position 5 Turn the engine switch to the ON position 6 Pull the recoil rope...

Страница 18: ...ower lines If the generator will be connected to a building electrical system consult your local utility company or a qualified electrician Connections must isolate generator power from utility power and must comply with all applicable laws and codes NOTE Connecting Electrical Loads 1 Let the engine stabilize and warm up for a few minutes after starting 2 Plug in and turn on the desired 120 Volt A...

Страница 19: ...ude The density of air at high altitude is lower than at sea level Engine power is reduced as the air mass and air fuel ratio decrease Engine power and generator output will be reduced approximately 3 for every 1000 feet of elevation above sea level This is a natural trend and cannot be changed by adjusting the engine At high altitudes increased exhaust emissions can also result due to the increas...

Страница 20: ...ase the START button The red light blinks once to program the remote 6 Push and hold the programming button approximately three seconds until the red light turns off 7 Test Start Stop features Only two remote controls can be in sync with one generator at a time NOTE Changing a remote control battery may not require the user to reset the remote control NOTE Parallel Operation Two 2 Champion model 1...

Страница 21: ...ay be performed by any non road engine repair establishment or individual NOTE Never operate a damaged or defective generator WARNING WARNING Improper maintenance will void your warranty WARNING Oil Cont d 0 7 0 8 mm 0 028 0 031 in Once oil has been added a visual check should show oil about 1 2 threads from running out of the fill hole If using the dipstick to check oil level DO NOT screw in the ...

Страница 22: ... 3 Remove the spark arrester screen 4 Carefully remove the carbon deposits from the spark arrester screen with a wire brush 5 Replace the spark arrester if it is damaged 6 Position the spark arrester in the muffler and attach with the two screws Failure to clean the spark arrester will result in degraded engine performance CAUTION To be performed by knowledgeable experienced owners or Champion Pow...

Страница 23: ... damage the generator windings CAUTION Remote Control Battery Disconnect the Battery 1 Remove the battery panel cover 2 Remove the protective cover from the black negative battery lead 3 Disconnect the black negative lead from the black negative terminal on the battery and store the cap screw and nut 4 Repeat steps 1 2 for the red positive battery lead 5 Store the battery in a cool dry place A Flo...

Страница 24: ...pecifications Model YF170FD 331 Displacement 192cc Type 4 Stroke OHV Start Type Wireless Remote Spark Plugs OEM spark plug NHSP F6RTC Replacement spark plug NGK BPR6ES or equivalent Make certain the spark plug gap is 0 7 0 8 mm or 0 028 0 031 in An Important Message About Temperature Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to ...

Страница 25: ...22 100261 ENGLISH SPECIFICATIONS Wiring Diagram ...

Страница 26: ...9 80 81 82 83 84 85 86 87 88 89 90 73 18 45 37 42 69 69 92 94 93 41 26 91 38 1 2 3 4 5 6 7 8 9 10 11 12 2 4 11 4 95 96 98 99 100 101 102 104 105 107 109 110 20 103 124 4 43 42 123 121 122 120 119 118 117 116 115 43 114 113 112 111 9 9 11 108 16 76 77 97 126 127 128 129 130 131 132 133 135 137 138 139 134 141 142 140 143 144 145 146 147 148 149 150 153 154 151 152 125 136 33 34 35 36 36 36 35 35 35...

Страница 27: ...ght Black 1 55 2 02 002 Nut M6 T Style 2 56 83 200705 01 Handle Upper Black 1 Part Number Description Qty 57 83 200705 02 Handle Lower Black 1 58 1 9074 3 0512 1 Screw Washer Assembly M5 x 12 Black 3 59 1 5789 0635 1 Flange Bolt M6 x 35 Black 2 60 83 190006 01 Rubber Sleeve End Cover 1 61 83 190003 01 End Cover Generator 1 62 83 190001 01 Fan Generator 1 63 2 02 006 Flange Nut M14 x 1 5 1 64 83 19...

Страница 28: ...lex 1 133 5 1210 920 20Amp Circuit Breaker Push Button 1 134 5 1210 930 30Amp Circuit Breaker Push Button 1 135 122 210003 01 Jacket Control Box 1 136 100261 21 10 Wire Assembly 1 137 1 9074 4 0512 Screw Washer Assembly M5 x 12 1 138 1 9074 4 0535 Screw Washer Assembly M5 x 35 1 139 83 210002 03 Control Box 1 140 1 6177 1 04 1 Lock Nut M4 Flange Black 6 141 1 818 0514 3 Screw M5 x 14 2 142 83 2100...

Страница 29: ...26 100261 ENGLISH This page intentionally left blank SPECIFICATIONS ...

Страница 30: ...8 60 62 63 64 65 68 67 69 70 72 74 75 78 32 31 29 30 28 26 25 53 50 44 43 42 41 40 39 37 36 35 24 23 21 20 19 18 17 16 15 14 13 12 1 2 3 4 5 6 7 8 9 10 11 38 33 66 84 85 86 89 90 61 5 5 22 27 34 108 107 106 73 71 76 77 47 48 49 59 46 103 95 94 96 97 98 99 100 101 102 104 105 52 51 45 48 34 109 110 ...

Страница 31: ...sher Assembly M5 x 10 4 55 83 080014 01 01 Air Guide Board 1 56 2 03 016 Washer Ø10 x Ø16 x 1 5 Drain Bolt 1 Part Number Description Qty 57 83 032000 00 Hose Oil Drain 1 58 28 030009 00 Gasket Cylinder Head 1 59 2 04 003 Dowel Pin Ø10 x 14 2 60 83 040006 01 Valve Exhaust 1 61 83 040002 01 Valve Intake 1 62 2 01 017 Stud Bolt M6 x 32 2 63 28 010100 00 Cylinder Head 1 64 2 15 002 Spark Plug F6RTC 1 ...

Страница 32: ...y switch to ON position Generator will not start electrically Generator battery is dead Recharge generator battery Battery switch is in the OFF position Turn battery switch to ON position Generator shuts down during operation Out of fuel Fill fuel tank Low oil level Fill crankcase to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Genera...

Страница 33: ...ent Normal maintenance is not covered by this warranty and is not required to be performed at a facility or by a person authorized by CPE Other Exclusions This warranty excludes Cosmetic defects such as paint decals etc Wear items such as filter elements o rings etc Accessory parts such as starting batteries and storage covers Failures due to acts of God and other force majeure events beyond the m...

Страница 34: ...table condition exits CPE will repair your small off road engine SORE at no cost to you including diagnosis parts and labor MANUFACTURER S WARRANTY COVERAGE This exhaust and evaporative emission control system is warranted for two years If any exhaust and evaporative emission related part on your engine or equipment is defective in the part will be repaired or replaced by CPE OWNER WARRANTY RESPON...

Страница 35: ...ed for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CPE according to Subsection d below Any such exhaust and evaporative emissions related part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period prior to the...

Страница 36: ... Mounting Brackets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof of original purchase date at your expense to any Champion Power Equipment dealer who is authorized by Champion Power Equipment Inc to sell and service that CPE product during his normal business...

Отзывы: