201003 - 5500W DUAL FUEL ELECTRIC START INVERTER GENERATOR
MAINTENANCE
29
Cleaning the Air Filter
1. Turn the maintenance cover fasteners to the unlocked
position and remove the cover.
2. Locate the air filter plastic cover and remove by rotating the
fastener counterclockwise and pull the cover off.
3. Remove the foam element.
4. Wash in liquid detergent and water. Squeeze thoroughly dry in
a clean cloth.
5. Saturate in clean engine oil.
6. Squeeze in a clean, absorbent cloth to remove all excess oil.
7. Place the filter in the assembly.
8. Reattach the air filter cover.
9. Reinstall the maintenance cover and rotate the fasteners to
the locked position.
Cleaning the Spark Arrestor
1. Allow the engine to cool completely before servicing the spark
arrestor.
2. Remove the two screws holding the cover plate which retains
the spark arrestor to the muffler.
3. Remove the spark arrestor.
4. Carefully remove the carbon deposits from the spark arrestor
with a wire brush.
5. Replace the spark arrestor if it is damaged.
6. Position the spark arrestor and cover plate on the muffler and
attach with the screws removed in step 2.
CAUTION
Failure to clean the spark arrestor will result in poor engine
performance.
NOTICE
Federal and local laws and administrative requirements
indicate when and where spark arrestors are required. When
ordered, spark arrestors are required for operation of this
generator in National Forest lands. In California, this generator
must not be used on any forest-covered land, brush-covered
land, or grass-covered land unless the engine is equipped with
a spark arrestor.
Replacing Fuel Fill Assist LED Batteries
1. Ensure the generator is off and the fuel dial is in the “OFF”
position.
2. Press down on the fuel light until you hear a click and the
light pops up.
3. Remove the screw as shown below and pull the light away
from the base while supporting the battery so it does not
hang freely and put tension on the battery connector wires.