Start by Reading These Important Safety Instructions

General safety guidelines

Before you begin the installation:
Please read the operating instructions and especially the precautions. Keep the manual for future reference

and pass it on to a possible subsequent owner.

The following symbols are placed in front of instructions to avoid personal injury or property damage. Read

these instructions carefully.

Important safety information

- The installer (specialist) must carefully read and

understand these instructions before starting any work.
Before first use and at least annually a specialist must
inspect powered windows, doors and gates regarding
their safe condition.
Specialist according to EN12635 is, who on the basis of
their technical training and experience, has sufficient
knowledge in the field of powered windows, doors and
gates and moreover is familiar with relevant state
occupational safety regulations and generally accepted
rules of technology in such an extent that he is also
able to assess the safe working condition of powered
windows, doors and gates.

- The door should be balanced. Unmoving or stuck doors

must be repaired. In an unbalanced state, garage
doors, door springs, cables, discs, brackets and rails
are under extreme tension, which can lead to serious
injury. Do not attempt to loosen, move or realign the
door, but contact service centre or a door professional.

- During the installation or maintenance of a door opener,

no jewellery, watches or loose clothing should be worn.

- To avoid serious personal injury due to entanglement,

remove all cables and chains connected to the door
before installing the door opener.

- During installation and electrical connection, the local

building and electrical regulations must be observed.
This device complies with Protection Class 2 and
does not require grounding.

- To avoid damage to very light doors (such as fibre

glass, aluminium or steel doors), an appropriate
reinforcement should be added.
To do so, contact the door manufacturer.

- The automatic safety reverse system should undergo a

test. Upon contact with a 50 mm high barrier on the
ground, the garage door MUST return. Failure to
properly adjust the door opener can result in serious
personal injury from a closing garage door. Repeat test
once a month and make any needed changes.

- This system must not be installed in damp or wet areas.

- During operation, the gate should not under any

circumstances obstruct public passageways.

- To remind all operators of the safe operation, in

addition to the illuminated wall switch a warning sign
to protect children should be affixed. The warning
signs about the risk of trapping should be placed in
clearly visible spots.

- Children should be supervised to ensure that they do

not play with the device.

- This device is not intended for use by persons

(including children) with restricted physical, sensory or
mental abilities or lack of experience and/or
knowledge, unless they are supervised by a person
responsible for their device.

- All barriers / locks are deactivated to avoid damage to

the door.

- If necessary, installed control equipment MUST be

mounted within sight of the door and out of reach of
children. Children should not be allowed to operate
the buttons or remote controls. Misuse of the door
opener can result in serious injury.

- The door opener should ONLY be used if the operator

can see the entire door area and is assured that it is
free of obstacles and the door opener is set correctly.
No one may pass through the door while it is moving.
Children must not be allowed to play in the vicinity of
the door.

- Use the manual release only for the separation of the

carriage from the drive and – if possible – ONLY with
the door closed.
Do not use the red handle to push the door up or pull
it down.

- Before performing any repairs or removing covers, the

door opener should be separated from the electric
power supply.

- This product has a transformer with a special power

cord. In case of damage this MUST be replaced with
an original transformer by aqualified technician.

- Operation of the emergency release can lead to

uncontrolled movements of the door, if springs are
weak or broken or if the door is unbalanced.

- Mount the release handle of the emergency release

at a height less than1.80 m.

Save these instructions

CAUTION Personal injury or property damage

CAUTION Danger due to electrical current or voltage

WARNING!

Содержание LM750EVGB

Страница 1: ...ing Garage Door Opener Installation and Operating Instructions Keep these instructions for future reference LM750EVGB Chamberlain GmbH Alfred Nobel Strasse 4 66793 Saarwellingen Germany www liftmaster...

Страница 2: ...rier on the ground the garage door MUST return Failure to properly adjust the door opener can result in serious personal injury from a closing garage door Repeat test once a month and make any needed...

Страница 3: ...14 OPERATING YOUR OPENER 15 CARE OF YOUR OPENER 15 MAINTAINING YOUR OPENER 15 SPECIFICATIONS 15 ACCESSORIES 16 TROUBLESHOOTING 17 DIAGNOSTIC CHART 18 DECLARATION OF CONFORMITY 18 These instructions a...

Страница 4: ...rtain to the edge of the bracket If the roller door drum wheel is on the edge of the curtain or is a smaller diameter additional clearance may be required Assemble the opener to the door axle and the...

Страница 5: ...d Diagnostic code indicator Number 1 2 Program UP indicator 3 Diagnostic code indicator Number 2 7 Control Button Used to activate the door when remote controls are not available Open Stop Close 8 Cou...

Страница 6: ...ected to the garage door Lift the door to about halfway and then release it The door should remain spring balanced Raise and lower the door to determine if there are any sticking or binding points 20...

Страница 7: ...r is installed the handle should be no higher then 1 8 metres from the floor The cord may need to be extended for high door installations Do not disengage the opener to manual operation with children...

Страница 8: ...les into the drive legs Align the holes on the extension poles with the holes on the drive legs Using the screws provided secure the extension poles Align the holes of the reinforcing brace with the t...

Страница 9: ...le U Bolt and door mounting bracket from the wall Install the opener Slide the opener over the door axle and engage the drive legs into the door drum wheel either side of a spoke Refit the door mounti...

Страница 10: ...il LED 3 will flash as well as LED 2 or LED 1 will flash For Right Hand setting LED 2 will flash and for Left Hand setting LED 1 will flash 2 To change to the opposite setting simply press the S butto...

Страница 11: ...ting refer to section 14 Repeat the safety reverse system test 15 40 mm Test obstacle 40 mm 16 TESTING THE SAFETY REVERSE SYSTEM After installing the operator on the door the force measurement of the...

Страница 12: ...h press DN button will reduce the count if needed Press and release the P button to accept this setting To deactivate the Timer to Close Start with the door fully CLOSED Press and Hold both P and DN b...

Страница 13: ...ntilation mode 1 Start with the door fully CLOSED figure 1 Drive the opener UP and stop at the position required for you wish to set the door at 2 Enter ventilation activation mode by pressing the P a...

Страница 14: ...re now erased 1 2 Flash x 2 BEEP DN DN UP UP P P S S 1 1 2 2 3 3 or Activate the opener only when door is in full view free of obstruction and properly adjusted No one should enter or leave the garage...

Страница 15: ...the S button on the garage door opener 1 Connect the ethernet cable to the Liftmaster Internet Gateway and the router 2 Connect power to the Liftmater Internet Gateway 3 Create an online account on t...

Страница 16: ...dby mode will need to be activated eg for using an external receiver To Activate NORMAL STANDBY mode Turn the mains power OFF Press and Hold both UP and DN buttons Turn ON mains power while both butto...

Страница 17: ...ding call for professional garage door service Check to be sure that the door opens and closes fully Set the limits and or force if necessary SPECIAL NOTE Liftmaster strongly recommends that obstructi...

Страница 18: ...side and remove the old battery Be sure to observe the polarity of the battery Assemble the transmitter again following the steps in reverse REPLACE BATTERIES IN REMOTES To prevent SERIOUS INJURY OR D...

Страница 19: ...ener lights flash 10 times Check the obstruction detection beams if you have installed this accessory If the red light on the beam is flashing the alignment is incorrect The red light on the beams may...

Страница 20: ...ure nothing is hanging or mounted on the door that would interrupt the sensors path while closing No RPM pulses have been detected Check the door manually for balance binding or obstructions Internall...