10
After installing and adjusting the door opener, photocells can be
installed.
The installation instructions are included with the photocells.
The optional photocells ensure that the door is open, or
remains open, if people, especially young children, are in the
door area.
By means of the photocells, a closing door is opened or an open
door is obstructed from closing, if a person located in the door area
interrupts the sensor beam.
Photocells are particularly recommended for families with young
children.
18
The door may operate unexpectedly, therefore do not allow anything to obstruct the path of the
door.
INSTALL THE OBSTRUCTION DETECTION BEAMS/ THE PROTECTOR SYSTEM
TM
(OPTIONAL ACCESSORY)
Automatic close feature (AC)
AUTOMATIC CLOSE feature: (AC) 10 to 180 seconds.
NOTE: The photo cells MUST be installed before AC will operate.
The Automatic Close feature allows the door to automatically close after a specified time period. During the
OPEN door waiting period, the courtesy light will flash continuoulsy.
If the door encounters an obstruction while closing, the opener will
return to the OPEN position and the waiting period will begin again.
To activate the Automatic Close:
• Start with obstruction detection beams installed and the door fully
CLOSED
• Press and Hold both “P” and “DN” buttons for 3 seconds. When the
Courtesy light flashes “TWICE”, release both buttons
• Press the “UP” for each 10 second interval required for
Timer to Close. A “BEEP” will register for each press. “DN” button
will reduce the count if needed.
• Press and release the “P” button to accept this setting
To deactivate the Timer to Close:
• Start with the door fully CLOSED
• Press and Hold both “P” and “DN” buttons for 3 seconds. When the
Courtesy light flashes “TWICE”, release both buttons.
• Press and release the “P” button to accept this setting
Auto close is NOT recommended for households with young children.
ACTIVATE
TIMER TO
CLOSE
SET
TIME
ACCEPT
SETTING
Flash x 2
BEEP
DN
DN
UP
UP
P
P
S
S
1
1
2
2
3
3
BEEP
DN
DN
UP
UP
P
P
S
S
1
1
2
2
3
3
Flash x 2
BEEP
DN
DN
UP
UP
P
P
S
S
1
1
2
2
3
3
ENABLING THE PROTECTOR SYSTEM:
• Connect the obstruction detection beam wiring to the opener and turn ON. (The obstruction detection
beams will automatically enable once they are connected and will now operate in a FAIL SAFE mode.)
DISABLING the obstruction detection beams:
If the obstruction detection beams are installed and needs to be removed the opener will need to be
reprogrammed.
Perform the power ON/OFF sequence as follows
• Remove the obstruction detection beam wires from the opener
• Turn the mains power OFF for 5 seconds
• Turn the power ON for 5 seconds
• Turn the power OFF for 5 seconds
• Turn the power ON and check the opener operates OK without the obstruction detection beams
SAFETY FIRST!
Whilst Liftmaster have engineered safety features into your garage door opener, we urge you to consider fitting
obstruction detection beams to your new garage door opener. In many countries these devices are compulsory
to assist in preventing serious injury or property damage. For your own peace of mind and the safety of others
please consider installing this safety device.