OPERATION AND MAINTENANCE
» RESET REMOTE C SLEEP MODE
OPERATOR ALARM
If a contact sensor detects an obstruction twice consecutively the alarm will
sound (up to 5 minutes) and the operator will need to be reset.
When the inherent force of the operator (RPM/current sensor) detects the
following (twice consecutively) the alarm will sound (up to 5 minutes) and the
operator will need to be reset:
A
B. The gate does not meet specifications.
C. Debris is on the gate's track such as mud, rocks, dirt, etc.
D. The gate has one or more broken axles or wheels.
E. The gate wheel is off the gate rail.
A. The gate is hitting a wall or vehicle.
B
C
D
E
SLEEP MODE
The operator enters sleep mode 15 seconds after the last command is given. The
diagnostic LED will blink in this mode. The photoelectric sensor indicator LEDs will not
be on. The next command given will return the operator to normal operation.
NOTE:
In dual gate applications the reset switch must be toggled on the
primary operator.
Remove any obstructions. Toggle the reset switch to shut off the alarm and reset
the operator. After the operator is reset, normal functions will resume.
RESET SWITCH
The reset switch is located on the front of the operator and serves several functions.
Toggling the reset switch will stop a moving gate during a normal open/close cycle,
like a stop button. The operator does not need to be reset after doing this.
PROGRAMMING LIMITS RESET
If a mistake is made while programming the limits toggle the reset switch to
start over.
MANUAL DISCONNECT
Press the reset switch to RESET/DISCONNECT to allow the gate(s) to be opened
and closed manually. On a dual gate application the reset switch must be
pressed on both operators. To resume normal operation press the reset switch to
NORMAL OPERATION.
RESET/
DISCONNECT
NORMAL
OPERATION
REMOTE CONTROL
Once the remote control has been programmed operator will operate as follows:
When gate is in the closed position, activation of the remote control button will open
the gate. During the open cycle another activation of the remote control will stop the
gate and the next activation of the remote control will close the gate.
When the gate is in the open position, activation of the remote control button will
close the gate.
24