INSTALLATION

Choose a convenient
location for installation.
It should be at eye
level, reachable by the
shortest person who
will use it, and within
sight of the door.
For a one-piece door,
choose the optional
location shown in the
illustration to avoid
injury as the door
swings up and out.
Test the reception of the Keyless Entry
by operating your opener from the
selected location. Change the location
if necessary.
Remove the battery compartment
cover to access the bottom 
mounting hole: 
• Insert a small phillips screw driver

into the small hole at the bottom of
the cover and gently pull 
outward to loosen.

• Slide the cover down to remove.
Center the keypad at eye level against the selected location.
Mark 4-1/4" up the centerline from the bottom and drill a 1/8"
pilot hole. Install top mounting screw, allowing 1/8" to protrude
above surface. Position keypad on screw head and adjust for
snug fit.
With cover open so bottom mounting hole is visible, use a
punch to mark hole. Remove keypad and drill 1/8" pilot hole.
Replace keypad and complete installation with bottom screw,
using care to avoid cracking plastic housing. Do not overtighten.
To replace the battery cover, insert the lip at the top and snap in
place.

THE KEYLESS ENTRY BATTERY

The 9 volt battery should produce
power for at least one year. Replace
when the keypad illumination
becomes dim.
Dispose of old batteries properly.

TO CHANGE AN EXISTING, KNOWN PIN

If the existing PIN is known, it may be changed by one 
person without using a ladder.
1. Press the four buttons for the present PIN, then press and

hold the # button.
The opener light will blink twice. Release the # button.

2. Press the new 4-digit PIN you have chosen, then

press ENTER.

The motor unit lights will blink once when the PIN has been
learned.
Test by pressing the new PIN, then press ENTER. The door
should move.

TO SET A TEMPORARY PIN

You may authorize access by visitors or service people with a
temporary 4-digit PIN. After a programmed number of hours or
number of accesses, this temporary PIN expires and will no
longer open the door. It can be used to close the door even
after it has expired. To set a temporary PIN:
1. Press the four buttons for your personal entry PIN (not the

last temporary PIN), then press and hold the 

button.

The opener light will blink three times. Release the 
button.

2. Press the temporary 4-digit PIN you have chosen, then press

ENTER.
The opener light will blink four times.

3. To set the number of 

hours

this temporary PIN will work,

press the number of hours (up to 255), then press

.

OR

3. To set the number of 

times

this temporary PIN will work,

press the number of times (up to 255), then press #.

The opener light will blink once when the temporary PIN has
been learned.
Test by pressing the four buttons for the temporary PIN, then
press Enter. The door should move. If the temporary PIN was
set to a certain number of openings, remember that the test
has used up one opening.To clear the temporary password,
repeat steps 1-3, setting the number of hours or times to 0 in
step 3.

SPECIAL NOTE:

The temporary password can ONLY be 

programmed to keypads working on a Chamberlain,
Craftsman

®

, or LiftMaster Garage Door Opener.  It WILL NOT

work on keypads programmed to an external receiver.

The temporary password will continue to CLOSE the door even
after the time has expired.  To eliminate this, program a new
temporary password into the keypad.

FOR SERVICE DIAL OUR TOLL FREE NUMBER: 
1-800-654-4736

To prevent possible SERIOUS INJURY or DEATH:

• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.

WARNING

CAUTION

WARNING

WARNING

Battery

Bottom
mounting hole

Battery
Cover

Door Jamb Edge

(Optional Location 

for 1-Piece Door)

Keypad

Door Jamb Face

SECTIONAL DOOR ONLY

KEYPAD MUST BE INSTALLED 

WITHIN SIGHT OF THE DOOR

Exterior Front Wall

1-Piece or 

Sectional Door

Typical 

Sectional Door

 Installation

Содержание 940C Security+

Страница 1: ...d hold ENTER 2 While holding the ENTER button press and hold the LIGHT button on the Multi Function Door Control 3 Continue holding the ENTER and LIGHT buttons while you press the push bar on the Multi Function Door Control all three buttons are held 4 Release buttons when the motor unit lights blink It has learned the code If light bulbs are not installed two clicks will be heard 1 Press and rele...

Страница 2: ...pressing the new PIN then press ENTER The door should move TO SET A TEMPORARY PIN You may authorize access by visitors or service people with a temporary 4 digit PIN After a programmed number of hours or number of accesses this temporary PIN expires and will no longer open the door It can be used to close the door even after it has expired To set a temporary PIN 1 Press the four buttons for your p...

Страница 3: ...dentification personnelle NIP à quatre chiffres de son choix sur le pavé numérique Enfoncer et tenir ensuite le bouton ENTER 3 Relâcher le bouton lorsque l éclairage du moteur clig note Il a appris le code Si les ampoules ne sont pas posées deux clics se feront entendre LOCK LIGHT DÉFINITION DU MOT DE PASSE PERSONNEL Nous vous recommandons de programmer votre mot de passe maintenant avant d instal...

Страница 4: ... programmé d heures ou d accès ce mot de passe temporaire expire et n ouvrira plus la porte Le mot de passe temporaire peut être utilisé pour fermer la porte même après l expiration du code jusqu à program mation d un nouveau mot de passe temporaire Pour changer le mot de passe temporaire 1 Appuyer sur mot de passe personnel non le dernier mot de passe temporaire appuyer ensuite sur le bouton et l...

Отзывы: