Challenger VKFCSD22IR Series Скачать руководство пользователя страница 20

 Connection and termination resistor

      The Rs485Bus standards require a daisy-chain 

connection between the equipment. There must be 

termination resistors with 120

Ω

(as the picture 9.4

-1). Please refer to picture 9.4-2 for simple

connection. D should not exceed 7m.

10.4  RS485Bus basic knowledge

120

Ω

1#       2#       3#       4#           32#

Picture 9-4.1

120

Ω

2400bps
4800bps

9600bps

1800m
1200m

800m

Baud rate

Max distance

19200bps

600m

      As specified by Rs485 standard, Rs485 Bus

is of half-duplexed data transmission cables with 

characteristic impedance as 120

Ω

. The maximum 

load capacity is 32unit loads(including main 

controller and controller equipment) 

 

Characteristics of Rs485 Bus

Transmission distances of Rs485 Bus

 

    When user selects the 0.56mm(24AWG) twist 

pair wires as data transmission cable, the max 

theoretical transmitting distance are as follows:

     If user selects thinner cables, or installs the 

dome in an environment with strong electroma-

gnetic interference, or connects lots of equipment 

to the Rs485Bus, the max transmitting distance 

will be decreased. To increase the maximum

transmitting distance, do the contrary. 

120Ω

1#       2#       3#       4#           32#

D

A+

B-

A+

B-

Picture 9.4-2

120Ω

 

Problems in practical connections

     In some circumstances user adopts a star 
configuration in practical connection. The
termination resistors must be connected to 
the two equipment 1# and 15# in picture 9.4-3. 
As the star configuration is not in conformity 
with the requirements of RS485 standards, 
problems such as signal reflections, lower 
anti-interference performance arise when 
the cables are long in the connection. The 
reliability of control signals is decreased 
with the phenomena that the dome does not 
respond or just responds at intervals to the 
controller, or does continuous operation 
without stop.

      
           

1#

32#

15#

   6 #

Mai n c ontroller

Picture 9.4-3

120

120

      In such circumstances the factory reco-
mmends the usage of RS485 distributor. 
The distributor can change the star config-
uration connection to the mode of connection 
stipulated in the RS485 standards. The new 
connection achieves reliable data transmi-
ssion (Refer to Picture 9.4-4).

RS485 Distributor

B-

1#

2#

3#

120

Ω

120

Ω

120

Ω

A+

120

120

120

Picture 9.4-4

3 5

Trouble

Possible cause

Solution

Dome can 

do self-

testing

but can

not be 

controlled

The dome can

be controlled

but the opera-

tion is not 

smooth

1. Chage the address and baud rate of contro-

     ller or dome

2. Adjust the + and -connection of Rs485

3. Make sure the connections are fully seated

4. Change RS485 Bus wires

1. Secure the connection

2. Replace RS485 bus wires

3. Add termination resistors to the 

    system

4. Install RS485 distributor

RS485Bus troubles shooting

1. The address and baud rate setting 

    of dome are not in conformity with 

    those of controller.

2. The + and - connection of RS485 

     Bus is incorrect

3. Bad connection 

4. There are circuit in the RS485

     Bus.

1. The RS485Bus is not in good contact with 

     the connectors

2. One wire of RS485bus is broken

3. The dome is very far from controller

4. There are two many domes connected in the 

     system

Ø

The connection of 120

Ω

 termination resistor

     Connect or disc
on the main board.  "1" set as "ON" means connect, and set 

 

 disconnect.

onnect the 120

Ω

 termination resistor by adjusting the eighth bit of the Sw2 

"0" as "OFF" means

SW2

SW1

3 6

Picture 9.4-5

Appendix

Appendix

Содержание VKFCSD22IR Series

Страница 1: ...Infrared Speed Dome Manual...

Страница 2: ...and s 5 1 2 5 1 3 M 5 2 5 3 5 4 Dome ID setting 5 5 Password setup 5 6 Clock setting 5 7 5 7 1 Power up action 5 7 2 PAN TILT setting 5 7 3 Time action setup 5 7 4 Park action setup 5 8 Defaults 6 Cam...

Страница 3: ...precise optical product Do not touch it directly to avoid scratches which can affect image quality Requirements to service personnel All the service work should be done by qualified technicians Don t...

Страница 4: ...product is high technology surveillance product with high definition and color camera variable speed pan tilt and multifunction decoder It can reduce the connection and installation process between sy...

Страница 5: ...ray and thus make the brightness of deferent image stable User may adjust iris by controlling keyboard to get required brightness that you need User also can resume auto Iris by joystick operation Whe...

Страница 6: ...5 1 1 Power up and self testing 5 1 3 Menu and keyboard operation DOME S N VERSION DOME S N VERSION PROTOCOL FACTOTY PROTOCOL FACTOTY DOME ID 001 DOME ID 001 BAUD RATE 4800bps BAUD RATE 4800bps MODEL...

Страница 7: ...2 Operate the joystick up and down and move the cursor to SYS TEM SETTING press OPEN to enter submenu 3 Operate the joystick up and down and move the cursor to DOME ID SETTING press OPEN to call dome...

Страница 8: ...ial one which is 000000 and then user may set the password by himself again MAIN MENU SYSTEM SETTING CAMERA SETTING FUNCTION SETTING DISPLAY SETUP EXIT SYSTEM SETTING EDIT DOME TITLE DOME INFO DOME ID...

Страница 9: ...to save Operate the joystick up and down and move the cursor to Operate the joystick and 5 7 2 PAN TILT setting When manually adjusting for far focus situation the dome responds at a high speed so th...

Страница 10: ...ESETS CLEAR ALL PATTERNS CLEAR ALL TOURS CLEAR ALL PRIVACIES FACTORY DEFAULTS RESTART restart the dome 4 The system enters into the main menu by calling 95 preset or by calling 9 preset twice within 3...

Страница 11: ...SETTING DISPLAY SETUP EXIT 6 1 3 Back light compensation 1 2 LENS PARAMETERS 3 4 The system enters into the main menu by calling 95 preset or by calling 9 preset twice within 3 seconds Operate the jo...

Страница 12: ...AE MODE SETTING AWE MODE SETTING ADVANCE PARAMETERS PRIVACY MASK BACK EXIT 19 MAIN MENU SYSTEM SETTING CAMERA SETTING FUNCTION SETTING DISPLAY SETUP EXIT Camera setting NOTICE This function is relativ...

Страница 13: ...and move the cursor to CAM ERA SETTING to enter submenu 3 Operate the joystick up and down and move the cursor to AE MODE SETTING press OPEN tilt up down joystick to choose AE mode modes for choosing...

Страница 14: ...camera does not have such function when the setting option shows N A CAMERA SETTING LENS PARAMETERS AE MODE SETTING AWB MODE SETTING ADVANCE PARAMETERS PRIVACY MASK BACK EXIT 6 3 White balance mode AW...

Страница 15: ...ling 9 preset twice within 3 seconds Click each command to enter preset menu according to the order of the left picture As follows preset and call preset function can be set by keyboard operation inpu...

Страница 16: ...s of other labels are the same as above NOTICE MAIN MENU SYSTEM SETTING CAMERA SETTING FUNCTION SETTING DISPLAY SETUP EXIT FUNCTION SETTING PRESETS SCAN PATTERNS TOUR ZONES BACK EXIT 1 left limit and...

Страница 17: ...f set the presets of the second line move the cursor to the second line press OPEN to continue edit Press OPEN to save after setting press CLOSE to exit TOUR NUMBER TOUR RUN TOUR CLEAR TOUR EDIT MAIN...

Страница 18: ...ime label 305 45 305 45 01X 01X Direction label Zoom magnification label 31 DISPLAY SETUP DOME TITLE OFF PRESET TITLE OFF ZOOM POSITION ON ZONES NAME OFF DIRECTION LABEL ON TEMPERATURE LABEL OFF TIME...

Страница 19: ...R GAIN N A B GAIN N A BACK EXIT AWB MODE SETTING SHARPNESS 05 HI RESOLUTION ON MAX GAIN 28dB EXPOS COMP N A BACK EXIT ADVANCE PARAMETERS PRIVACYNUMBER 01 EDIT PRIVACY ENABLE PRIVACY OFF CLEAR PRIVACY...

Страница 20: ...e cables are long in the connection The reliability of control signals is decreased with the phenomena that the dome does not respond or just responds at intervals to the controller or does continuous...

Страница 21: ...26 27 28 29 30 31 32 20 21 22 23 24 1 1 1 1 1 0 0 0 0 0 0 0 0 1 0 0 Bit 1 2 3 4 5 6 7 8 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 0 1 0 0 0 0 0 0 1 1 0 0 0 0 0...

Страница 22: ...0 0 0 1 1 0 1 0 0 0 0 1 0 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 132 133 134 135 39 S w i t c h n u m b e r ID Bit 1 2 3 4 5 6 7 8 S w i t c h n u m b e r ID 1 2 3 4 5 6 7 8 Bit Sw1 Sw1 0 0 0 1 0 0 0 1 1 0 0 1...

Страница 23: ...tortious won t exceed the amount of the products The factory won t bear any responsibility for the special unexpected and continue damage caused by any other reasons Our company has the final right of...

Страница 24: ...ESET Enter menu CALL 94 PRESET Restart CALL 92 PRESET Set scan1 Left limit CALL 93 PRESET Set scan1 Right limit CALL 97 PRESET Run scan1 CALL 99 PRESET Run pattern 1 CALL 62 PRESET Open IR LED manual...

Отзывы: