background image

 

STEP 4:

  

Mount Power Head to Ceiling:

  Since there is such variety in ceiling structures, all the mounting 

possibilities for the Power Unit cannot be illustratlocation of, and attachment to, ceiling joists, a carpenter 
should be contacted to provide assistance.  A cross brace will be necessary if power head is mounted here.  The 
main concern is mounting the Power Unit securely to the 
ceiling joists for operational strength, rigidity and safety.  
Although there are a series of mounting slots provided on 
the power unit, try to 

secure the mounting straps in the 

slots closest to the front.

  Mounting may usually be 

accomplished using standard 1-1/4“ perforated steel angle 
available at most hardware stores.  If in doubt about is 
mounted 8” or more from the ceiling.  

 

 

STEP 5:

  Return to the Rail/Wall Mounting 

Bracket 

and securely tighten the bolt and nut that connect 

the Rail Front Idler bracket and the Wall Mounting 
Bracket.  Take care not to over tighten the nut; tighten 
only until the end of the bolt is (See Step 2).

 

Mounting The Power Head 
End of Opener 

 

STEP 6: 

Align the center of opener 

tracks with the center line previously 
marked on the top section of the garage 
door to ensure rail will be parallel with 
the direction of door travel. 

 

Use supplied hangers from the ceiling 
beams to hang the opener at the power 
head end (be sure to locate and mount to 
the solid structural beams, as illustrated).  Predrill with 3/16” drill bit and use supplied 1/4” x  1-1/2” lag screws 
to ensure a rigid mount. 

 

NOTE:  Hanging brackets should be at an angle to provide rigid support.  If hangers have no angle or if you use 
longer hangers, cross brace the hangers to eliminate the possibility of sway during operation of the opener.

 

110050-2 

For finished ceilings, or if structural 

beams are out of position for 

mounting use a third mounting angle 

(not included) making sure it is 

securely mounted to beams. 

Cut and bend 

Hangers to fit 

Opener 

Power 

Head 

Structural 

Beams 

STEP 7:  Door Bracket Installation

 

 

NOTE:  If the door is of light construction it may be necessary 
to reinforce the center stile with steel angle or wood to prevent 
damage to the door if it encounters an obstruction on closing.  
Mount the door bracket using two 1/4”-20 x 2” carriage bolts 

and 1/4” nuts 
(supplied), on center 
line of door with the 
middle hole in line 
with the top rollers. 

 

WARNING 

 

If your door comes equipped with a strut 
mounted opener bracket, proceed to Step 8. 

110051-1 

C: INSTALLING THE OPERATOR 

 

SECTIONAL DOORS 

AND ONE-PIECE 

DOORS WITH TRACKS

ONE PIECE DOORS  

WITHOUT TRACKS 

position.  Allow 2” of space between the tee rail and the door (at the high arc position) as shown in the 

illustration on page 9.  The opener will be angled as shown.  This is necessary for proper operation.   

 

NOTE: 

 Since the opener will  be secured permanently in this position, open and close the door a few times to be 

sure the door does not rub on the Tee Rail and that you have allowed the proper clearances before proceeding.  

Reinforce Door 

Vertically and 

Horizontally 

110051-2 

Top Roller 

Guideline 

Door Center Line 

Mounting 

Bracket 

Top Roller 

Guideline 

Fiberglass, aluminum or lightweight steel 

garage doors will require reinforcement before 

installation of the door mounting bracket  

Contact your door manufacturer for a 

reinforcement kit or instructions.

 

ALLOW 2”  BETWEEN TOP 

OF DOOR AND RAIL 

DOOR 
FULLY 

OPEN 

TOP OF 

DOOR IN 

HIGH ARC 

POSITION 

ALLOW 2”  BETWEEN 

HIGH ARC OF DOOR 

AND RAIL

 

104373 

Содержание 9000M SERIES

Страница 1: ...TEMENTS CAREFULLY AND FOLLOW THE INSTRUCTIONS CLOSELY The Warning and Caution boxes throughout this manual are there to protect you and your equipment Pay close attention to these boxes as you follow...

Страница 2: ...or automatic operation of the door is again desired initiating operation in the normal manner Push Button Radio Control etc will effect automatic reconnection of the Manual Release Mechanism Page 9 Se...

Страница 3: ...MANUAL RELEASE TAG DOOR BRACKET BELL WIRE SPOOL WALL BRACKET DOOR ARM and ROD SENSOR U BRACKET SAFE FINISH SENSOR L BRACKET RED RELEASE KNOB PHOTOSYSTEM SENSORS 110046 PUSHBUTTON WARNING LABEL 110045...

Страница 4: ...secure the Rail Chain assembly to the Power Head Unit making sure they are tight Assembly is now complete and you are ready to begin installation of the opener ASSEMBLY INSTRUCTIONS WARNING SPRINGS PU...

Страница 5: ...WEAR SAFETY GOGGLES OR OTHER PROTECTIVE EYEWEAR IF POSSIBLE INSTALL THE DOOR OPENER 7zFT OR MORE ABOVE THE FLOOR MOUNT THE EMERGENCY RELEASE 6 FT ABOVE THE FLOOR REINFORCE LIGHTWEIGHT FIBERGLASS ALUM...

Страница 6: ...oor This is the high arc rise of the door Unclamp and close the door Using the table below draw a horizontal line at the appropriate height above the door to intersect with the vertical centerline Mou...

Страница 7: ...cross brace the hangers to eliminate the possibility of sway during operation of the opener 110050 2 For finished ceilings or if structural beams are out of position for mounting use a third mounting...

Страница 8: ...ket Visually align the door arm connecting hole with the connecting pin of the strut by rotating the tube section in the appropriate direction Release the trolley leave door arm attached with the manu...

Страница 9: ...ion Ground Wire 110053 1 110055 1 Closed Limit Stop Location Open Limit Stop Location Fully Open Fully Closed Trolley Door Arm Connection Door Arm Door Arm Bracket Open Door Closed Door Door Arm IMPRO...

Страница 10: ...screws STEP 3 Run the wire from the standard wall pushbutton to the operator supporting it at 18 intervals with suitable staples Leave a sufficient length to make the necessary connections to the open...

Страница 11: ...ontinue to hold both the and buttons until the LED starts to blink approximately 5 seconds When the LED starts to blink IMMEDIATELY release both the and buttons The LED will blink two times and then r...

Страница 12: ...le However environmental conditions and the location of the transmitter and receiver antenna will affect distance If the opener doesn t activate check if the power head unit has been programmed to acc...

Страница 13: ...s Refer to wiring diagrams on page 14 19 for the Safe Finish Photosystem connection illustration A Remove the transmitter and receiver from their U mounting brackets Run a wire pair not supplied aroun...

Страница 14: ...espect to the floor the door is closed 3 The Manual Release Label and cord are secure to the Manual Release Lever The handle is located 6 FT above floor level and requires no more than a 50 pound pull...

Страница 15: ...en reaches the down limit the lamp will blink off for a 1 2 second then turn back on again remaining on for 4 minutes 30 seconds and will then automatically turn off MOVING UPWARD then reaches the ope...

Страница 16: ...dditional check Operate manual release on the trolley and allow the door to seek its natural fully open position then move the open limit stops to align trolley to this position If the door does not o...

Страница 17: ...below and stops in the fully closed position proceed to Adjustment 6 If the door reverses when it comes into contact with the floor move the close limit stop located on the left side inside looking ou...

Страница 18: ...tained E Tighten all mounting screws and bolts loop and secure any extra wire Important Test Photoelectric Obstruction Test Test Procedure Place an object 6 x 12 on the floor as illustrated progressiv...

Страница 19: ...e 12 for illustration Contact the factory if your problem persists or is not listed DIAGNOSTIC CONDITION RED LED GREEN LED Normal Operation OFF OFF Learn Mode ON OFF Memory Full ON FOR 25 SEC AUTO OFF...

Страница 20: ...ed at Allstar s sole option at no cost and returned pre paid Defective parts will be repaired or replaced with new or factory rebuilt parts at Allstar s sole option This limited warranty does not cove...

Отзывы: