background image

Serial #: 

Date Installed: 

Your Dealer: 

 

c.p. Allstar Corporation 
Downingtown, PA  19335 

This garage door opener is built in the USA 
and complies with all requirements of 
Underwriters Laboratories Standard UL-325.   
P/N 112075 

Rev. B 

     March  2006

 

 

Manufacturer’s Limited Warranty

 

Allstar warrants its 9000M Series Challenger residential vehicular garage door openers as follows: 

A. 

   The drive train to be free from defects in materials and workmanship for: 

 

Models 9300M/9500M/J9500M:  for 10 years from the date of purchase by the 

  original 

purchaser. 

 

The drive train includes the motor, rails, frame and chain. 

B.

  The controller circuit board, capacitor, photobeams and all other parts in all models will be free 

from defects in materials and workmanship for a period of two (2) years from the date of purchase 
by the original purchaser. 

Contact your dealer to obtain service for your opener . 

To obtain service under this warranty the buyer must obtain authorization instructions for the return of 
any goods from Allstar before returning the goods.  The goods must be returned with complete 
identification, with copy of proof-of-purchase, freight prepaid and in accordance with Allstar's 
instructions or they will not be accepted.  In no event will Allstar be responsible for goods returned 
without proper authorization or identification. 

Goods returned to Allstar for warranty repair within the warranty period, which upon receipt by Allstar 
are confirmed to be defective and covered by this limited warranty, will be repaired or replaced at 
Allstar's sole option, at no cost and returned pre-paid.  Defective parts will be repaired or replaced with 
new or factory rebuilt parts at Allstar’s sole option. 

This limited warranty does not cover non-defect damage, damage caused by unreasonable use, damage 
caused by improper installation or care, vandalism or lightning, fire or excessive heat, flood or other acts 
of God (including, but not limited to misuse, abuse or alterations, failure to provide reasonable and 
necessary maintenance), labor charges for dismantling or reinstalling a repaired or replaced unit, or 
replacement batteries. 

These warranties are in lieu of all other warranties, either expressed or implied.  All implied warranties 
of merchantability and/or fitness for a particular purpose are hereby disclaimed and excluded.  Under no 
circumstances shall Allstar be liable for consequential, incidental or special damages arising in 
connection with the use or inability to use this product.  In no event shall Allstar’s liability for breach of 
warranty, breach of contract, negligence or strict liability exceed the cost of the product covered hereby.  
No person is authorized to assume for Allstar any other liability in connection with the sale of this 
product. 

This warranty gives you specific legal rights.  You may also have other rights which vary from state to 
state.  Warranty effective after May 1, 2004.

 

See Page 14 for Radio System 
programming instructions and 
FCC/RSS-210 Industry Canada 
statement.  Allstar opener radio 
systems are HomeLink® 
compatible. 

Code Position 

Ö

  1 

 Plus 

(+) 

Button 

 

 

 

 

 

 

 

 

 

Zero 

(0) 

Button  

 

 

 

 

 

 

 

 

 

Minus 

(-)

 Button  

 

 

 

 

 

 

 

 

 

Your Radio System can learn 

8 different

 

transmitter codes.  See Page 14 and, if desired, record your code settings below.

 

 

Содержание 9000M SERIES

Страница 1: ...TEMENTS CAREFULLY AND FOLLOW THE INSTRUCTIONS CLOSELY The Warning and Caution boxes throughout this manual are there to protect you and your equipment Pay close attention to these boxes as you follow...

Страница 2: ...or automatic operation of the door is again desired initiating operation in the normal manner Push Button Radio Control etc will effect automatic reconnection of the Manual Release Mechanism Page 9 Se...

Страница 3: ...MANUAL RELEASE TAG DOOR BRACKET BELL WIRE SPOOL WALL BRACKET DOOR ARM and ROD SENSOR U BRACKET SAFE FINISH SENSOR L BRACKET RED RELEASE KNOB PHOTOSYSTEM SENSORS 110046 PUSHBUTTON WARNING LABEL 110045...

Страница 4: ...secure the Rail Chain assembly to the Power Head Unit making sure they are tight Assembly is now complete and you are ready to begin installation of the opener ASSEMBLY INSTRUCTIONS WARNING SPRINGS PU...

Страница 5: ...WEAR SAFETY GOGGLES OR OTHER PROTECTIVE EYEWEAR IF POSSIBLE INSTALL THE DOOR OPENER 7zFT OR MORE ABOVE THE FLOOR MOUNT THE EMERGENCY RELEASE 6 FT ABOVE THE FLOOR REINFORCE LIGHTWEIGHT FIBERGLASS ALUM...

Страница 6: ...oor This is the high arc rise of the door Unclamp and close the door Using the table below draw a horizontal line at the appropriate height above the door to intersect with the vertical centerline Mou...

Страница 7: ...cross brace the hangers to eliminate the possibility of sway during operation of the opener 110050 2 For finished ceilings or if structural beams are out of position for mounting use a third mounting...

Страница 8: ...ket Visually align the door arm connecting hole with the connecting pin of the strut by rotating the tube section in the appropriate direction Release the trolley leave door arm attached with the manu...

Страница 9: ...ion Ground Wire 110053 1 110055 1 Closed Limit Stop Location Open Limit Stop Location Fully Open Fully Closed Trolley Door Arm Connection Door Arm Door Arm Bracket Open Door Closed Door Door Arm IMPRO...

Страница 10: ...screws STEP 3 Run the wire from the standard wall pushbutton to the operator supporting it at 18 intervals with suitable staples Leave a sufficient length to make the necessary connections to the open...

Страница 11: ...ontinue to hold both the and buttons until the LED starts to blink approximately 5 seconds When the LED starts to blink IMMEDIATELY release both the and buttons The LED will blink two times and then r...

Страница 12: ...le However environmental conditions and the location of the transmitter and receiver antenna will affect distance If the opener doesn t activate check if the power head unit has been programmed to acc...

Страница 13: ...s Refer to wiring diagrams on page 14 19 for the Safe Finish Photosystem connection illustration A Remove the transmitter and receiver from their U mounting brackets Run a wire pair not supplied aroun...

Страница 14: ...espect to the floor the door is closed 3 The Manual Release Label and cord are secure to the Manual Release Lever The handle is located 6 FT above floor level and requires no more than a 50 pound pull...

Страница 15: ...en reaches the down limit the lamp will blink off for a 1 2 second then turn back on again remaining on for 4 minutes 30 seconds and will then automatically turn off MOVING UPWARD then reaches the ope...

Страница 16: ...dditional check Operate manual release on the trolley and allow the door to seek its natural fully open position then move the open limit stops to align trolley to this position If the door does not o...

Страница 17: ...below and stops in the fully closed position proceed to Adjustment 6 If the door reverses when it comes into contact with the floor move the close limit stop located on the left side inside looking ou...

Страница 18: ...tained E Tighten all mounting screws and bolts loop and secure any extra wire Important Test Photoelectric Obstruction Test Test Procedure Place an object 6 x 12 on the floor as illustrated progressiv...

Страница 19: ...e 12 for illustration Contact the factory if your problem persists or is not listed DIAGNOSTIC CONDITION RED LED GREEN LED Normal Operation OFF OFF Learn Mode ON OFF Memory Full ON FOR 25 SEC AUTO OFF...

Страница 20: ...ed at Allstar s sole option at no cost and returned pre paid Defective parts will be repaired or replaced with new or factory rebuilt parts at Allstar s sole option This limited warranty does not cove...