C. Connect the interconnect wire pair to the garage
door opener terminals marked
"1"
&
"4"
.
Although
not required, it is suggested that the "trace" be
connected to Terminal 4. See wiring diagrams,
below and page 19.
Tighten all mounting screws and bolts. Final
alignment and the system test is covered on Page 18,
“Operation and Adjustment Instructions”.
D: CONTROL AND AUXILIARY EQUIPMENT
PRE-POWER ON-
INSTALLATION CHECKLIST
Before continuing with the operation and
adjustment section, make sure that
:
1. The front and rear mounts for the opener are sound
and secure and the rail is positioned correctly
above the high arc of the door, and that the opener
is positioned over the door action centerline.
2. For sectional door and one piece door with tracks,
the position of the door arm (with the door closed),
is such that it’s connecting point on the trolley is
5” to 8” behind it’s connecting point on the door
bracket. The door arm should never be perfectly
vertical when the door in in the closed position.
For one piece doors without tracks, the position of
the door arm (with the door closed) is such that it’s
connecting point on the trolley is approximately
30” behind it’s connecting point on the door
bracket. The straight portion of the door arm
should be at an angle of 15-20° with respect to the
floor the door is closed.
3. The Manual Release Label and cord are secure to
the Manual Release Lever. The handle is located 6
FT above floor level and requires no more than a
50 pound pull to activate. The trolley and the
release mechanism are properly lubricated.
4. All push button controls are mounted at such a
position and of such height that they can only be
actuated by an adult of average height. The
Control Button Warning label is prominently
displayed next to the push button or Super Station.
5. All wiring is correct to codes or better. There is
ground continuity form the supply. The ground
prong on the power cord is intact.
6. All ropes have been removed from the door. The
door moves freely without binding when raised or
lowered manually. The door is correctly balanced
and lubricated. All door hardware is secure and
sound. The sensitivity has been adjusted to
minimum force for the application.
7. The concrete or other surface beneath the closed
door provided uniform contact.
8. The plastic envelope for this manual is attached to
the wall near the push button or wall station and
this manual is placed there for owner use and
reference.
9. On door with extension type counterbalance
springs, restraint cables have been placed through
the springs.
10. There is Ground Fault Interruption (GFI)
protection of the power line to the opener or in
the receptacle.
11. On doors with adjustable bottom edges, edges
have been locked after adjustment.