background image

Step  12:

  

Install a 

Rough Service

 lamp bulb (75 Watt maximum) firmly 

in the light socket.  Light bulbs in door openers are subject to vibration 
during normal operation which may shorten their life spans.  Rough Service 
bulbs, available at most hardware stores, are recommended. Fit Light 
Diffuser tabs into the panel tabs as shown.  

STEP 11: Connecting The Electrical Power

  

Consult the label on the rear panel of the Opener to 

determine its proper working voltage.  Normally it will be marked for 115V, 60 cycle operation.  (If it is an export 
model designed for 220V, 50 cycle operation, the label will clearly indicate this.) The Opener must be plugged 
into a properly grounded receptacle within 3 FT of the Power Unit.   

A GFI Type receptacle is recommended.

  

Do not use 2-prong adapters and do not use extension cords for anything more than temporary hook-up and testing 
purposes.  Receptacle wiring should be No. 14 or heavier, and 

must be in compliance with local building and 

electrical codes.

  

If local codes require permanent wiring, a GFI type circuit breaker is recommended to protect the line.  Remove 
the Strain Relief Bushing and withdraw the Line Cord from the rear of the Power Unit to expose the three 
insulated connectors.  Cut the wire at the rubber jacket of the Line Cord and wire in permanently, employing 
proper wiring practices.  Discard Strain Relief.  It is not used with permanent wiring.  

Using the two wires (black & white) that were left the 

line cord was cut, splice in the permanent connections

Permanent Wiring Connection 

Normal  

Connection 

Ground Wire 

110053-1 

110055-1 

Closed Limit 
Stop Location 

Open Limit 
Stop Location 

Fully Open 

Fully Closed 
Trolley 

Door Arm 
Connection 

Door Arm 

Door Arm 

Bracket 

Open 

Door 

Closed Door 

Door Arm 

IMPROPER WIRING COULD CAUSE 

ELECTROCUTION OR DAMAGE TO 

CIRCUITRY.  FOLLOW LOCAL 

BUILDING AND ELECTRICAL CODES. 

 

 

WARNING 

C: INSTALLING THE OPERATOR 

Slide door arm and trolley toward door; connect 
the tube assembly to the door bracket with the 
3/8” diameter bolt and locking nut, tightening 
enough to allow for door arm pivot.  Do not 
overtighten the locking nut. 
 
Press door control button and run opener through 
full open and close cycles, adjusting the limit 
stops as required to fully open and close the door.  
At full closed position, the door arm assembly 
should compress approximately one inch. 

HOW TO OPERATE THE DOOR MANUALLY - 

MANUAL RELEASE DISCONNECT 

The door should be fully closed, if possible, before 
using the manual disconnect.  Weak or broken 
springs could allow an open door to fall rapidly.  
Property damage or serious personal injury could 
result.  Do not use the manual release handle to pull 
the door open or closed. 
 

Your opener is equipped with a manual release recessed 
trolley-type disconnect system, enabling manual 
operation of the garage door during a power failure. 
 
The trolley is disconnected from the chain by pulling 
down on the red release handle, allowing the garage 
door to be operated manually. 

 
The trolley will 
automatically 
reconnect when 
power is 
restored and the 
door is 
activated. 
 
If the manual release is used, close the door before 
reactivating the opener. 
 

NOTE:  Outside keylock manual releases are an 
available accessory and are recommended for 
garages without a service entrance.

 

Manual 

Release 

Knob 

Trolley 

Clips 

Содержание 9000M SERIES

Страница 1: ...TEMENTS CAREFULLY AND FOLLOW THE INSTRUCTIONS CLOSELY The Warning and Caution boxes throughout this manual are there to protect you and your equipment Pay close attention to these boxes as you follow...

Страница 2: ...or automatic operation of the door is again desired initiating operation in the normal manner Push Button Radio Control etc will effect automatic reconnection of the Manual Release Mechanism Page 9 Se...

Страница 3: ...MANUAL RELEASE TAG DOOR BRACKET BELL WIRE SPOOL WALL BRACKET DOOR ARM and ROD SENSOR U BRACKET SAFE FINISH SENSOR L BRACKET RED RELEASE KNOB PHOTOSYSTEM SENSORS 110046 PUSHBUTTON WARNING LABEL 110045...

Страница 4: ...secure the Rail Chain assembly to the Power Head Unit making sure they are tight Assembly is now complete and you are ready to begin installation of the opener ASSEMBLY INSTRUCTIONS WARNING SPRINGS PU...

Страница 5: ...WEAR SAFETY GOGGLES OR OTHER PROTECTIVE EYEWEAR IF POSSIBLE INSTALL THE DOOR OPENER 7zFT OR MORE ABOVE THE FLOOR MOUNT THE EMERGENCY RELEASE 6 FT ABOVE THE FLOOR REINFORCE LIGHTWEIGHT FIBERGLASS ALUM...

Страница 6: ...oor This is the high arc rise of the door Unclamp and close the door Using the table below draw a horizontal line at the appropriate height above the door to intersect with the vertical centerline Mou...

Страница 7: ...cross brace the hangers to eliminate the possibility of sway during operation of the opener 110050 2 For finished ceilings or if structural beams are out of position for mounting use a third mounting...

Страница 8: ...ket Visually align the door arm connecting hole with the connecting pin of the strut by rotating the tube section in the appropriate direction Release the trolley leave door arm attached with the manu...

Страница 9: ...ion Ground Wire 110053 1 110055 1 Closed Limit Stop Location Open Limit Stop Location Fully Open Fully Closed Trolley Door Arm Connection Door Arm Door Arm Bracket Open Door Closed Door Door Arm IMPRO...

Страница 10: ...screws STEP 3 Run the wire from the standard wall pushbutton to the operator supporting it at 18 intervals with suitable staples Leave a sufficient length to make the necessary connections to the open...

Страница 11: ...ontinue to hold both the and buttons until the LED starts to blink approximately 5 seconds When the LED starts to blink IMMEDIATELY release both the and buttons The LED will blink two times and then r...

Страница 12: ...le However environmental conditions and the location of the transmitter and receiver antenna will affect distance If the opener doesn t activate check if the power head unit has been programmed to acc...

Страница 13: ...s Refer to wiring diagrams on page 14 19 for the Safe Finish Photosystem connection illustration A Remove the transmitter and receiver from their U mounting brackets Run a wire pair not supplied aroun...

Страница 14: ...espect to the floor the door is closed 3 The Manual Release Label and cord are secure to the Manual Release Lever The handle is located 6 FT above floor level and requires no more than a 50 pound pull...

Страница 15: ...en reaches the down limit the lamp will blink off for a 1 2 second then turn back on again remaining on for 4 minutes 30 seconds and will then automatically turn off MOVING UPWARD then reaches the ope...

Страница 16: ...dditional check Operate manual release on the trolley and allow the door to seek its natural fully open position then move the open limit stops to align trolley to this position If the door does not o...

Страница 17: ...below and stops in the fully closed position proceed to Adjustment 6 If the door reverses when it comes into contact with the floor move the close limit stop located on the left side inside looking ou...

Страница 18: ...tained E Tighten all mounting screws and bolts loop and secure any extra wire Important Test Photoelectric Obstruction Test Test Procedure Place an object 6 x 12 on the floor as illustrated progressiv...

Страница 19: ...e 12 for illustration Contact the factory if your problem persists or is not listed DIAGNOSTIC CONDITION RED LED GREEN LED Normal Operation OFF OFF Learn Mode ON OFF Memory Full ON FOR 25 SEC AUTO OFF...

Страница 20: ...ed at Allstar s sole option at no cost and returned pre paid Defective parts will be repaired or replaced with new or factory rebuilt parts at Allstar s sole option This limited warranty does not cove...

Отзывы: