Motor
1) Remove the cover of motor junction box.
2) Verify the jumper setting corresponds to the
line voltage.
3) Reinstall cover of motor junction box.
Motor Cable
Motor Cable
#1 #2 #3
#1 #2 #3
CLM16
IOM.
DOC
5/8/09
For 208/230 V, three jumpers
must be set vertically.
For 440/480 V, two jumpers must be set
horizontally in the lower row of terminals.
Final Checkout Procedure
Visually check the columns for shipping damage.
Run the lift through several full cycles.
Ensure that all controls are operating correctly.
Ensure that carriages are synchronized during the up and down movements.
Operational Test
Load the lift with a vehicle appropriate for this lift.
Run the lift through several full cycles.
Ensure that all controls are operating correctly.
Ensure that carriages are synchronized during the up and down movements.
Содержание CLM16
Страница 10: ...Specifications CLM16 IOM DOC 5 8 09...
Страница 21: ...SMA 2H Standard Carriage Wide Body Carriage CLM16 IOM DOC 5 8 09...
Страница 22: ...SMA 2 Standard Carriage CLM16 IOM DOC 5 8 09 Wide Body Carriage...
Страница 33: ...Lower Limit Switch CLM16 IOM DOC 5 8 09...
Страница 43: ...Column Base Frame Height 2 CLM16 IOM DOC 5 8 09...
Страница 45: ...Column Cover CLM16 IOM DOC 5 8 09...
Страница 47: ...Dolly CLM16 IOM DOC 5 8 09...
Страница 49: ...Drive Assembly CLM16 IOM DOC 5 8 09...
Страница 51: ...Carriage Standard CLM16 IOM DOC 5 8 09...
Страница 53: ...Universal CLM16 IOM DOC 5 8 09...