Jumper Setting
CAUTION
Prior to initial operation make sure the jumpers are set correctly. Non-compliance
may result in damage to motor and power supply unit !!!
Power Supply Unit
208/230 V
440/480 V
!!! Before opening power supply unit (MCB), ensure that it is disconnected from the Main
Power Supply (Wall Outlet) !!!
1) Open the power supply unit.
2) For ease of access, unlock main switch Q 1 (see illustration) and pull it off the square pin.
3) Verify the jumper setting corresponds to the line voltage.
4) If necessary, change the jumper setting using needle nose pliers.
5) Reinstall and lock the main switch.
6) Close the power supply unit.
CLM16
IOM.
DOC
5/8/09
Содержание CLM16