AQUASPEED
Maintenance
Never work on a pump without turning the power off
The strainer basket in the hair and lint pot bowl should be inspected and cleaned at regular intervals.
1. Remove lid and lift out basket
2. Remove debris and hose off with clean water if necessary
3. Inspect the lid gasket, if needed lubricate with
silicone based grease
only or if damaged replace
4. Replace the strainer
5. Re-prime the hair and lint pot bowl
6. Correctly locate the o-ring
7. Replace the lid,
tighten by hand
only
8. Switch on pump
In climates where the pump may be exposed to frost or freezing, care must be taken to ensure the pump is protected from damage.
It is recommended that if the pump is not used during this winter period it should be drained completely. A drain plug is provided for
this purpose.
Do not replace the drain plug. Store it in a safe place until you require the use of the pump. (An example would be within the hair
and lint pot bowl basket.)
If at all possible remove the pump away and store it in a dry location during this period.
When you reactivate the pump ensure all seals and o-rings are in operational condition, re-grease if necessary and replace if unsure
of condition.
• Check that the motor shaft moves freely before reactivation
Fluid Temperature
The permissible temperature is between
0°C and 40°C
. The pump should never be operated outside of these temperatures or
damage may occur.