Location 

The pump must be located as close as practical to the pool. The pump must also be in a position that enables easy access for 
periodic servicing. 

Care must also be taken to position the pump in an area that is free from flooding and is a well ventilated and dry (The pump motor 
cooling fan must have a minimum clearance of 150mm). 

Installation 

1.  The pump suction line should not be smaller than the unions supplied with the pump
2.  The suction line is to have as few bends or elbows as possible. There must not be an air trap on the suction line 
3.  Use only the pump barrel unions supplied with the pump 
4  Bolt the pump to the required position to prevent movement
5.   The pump electrical cable must be wired for the proper voltage and rotation in accordance with the wiring instructions
6.   All wiring (electrical) work must be carried out by a licensed electrician and must be installed in accordance to the local codes
7.  The motor must be grounded
8.  The weight of the plumbing and fittings is to be independently supported and not carried by the pump
9.  The pump motor cooling fan must have a minimum clearance of 150mm

Important Electrical Notice 

The electrical installation is to be done by a licensed electrician. 

Each pump requires a circuit breaker to separate the pump from the electrical supply. (The contact separation has to provide full 
disconnection in all poles under overvoltage category Ill conditions.) 

If the pump is to be installed on a swimming pool or pond situation it is 

MANDATORY

 that an earth leakage circuit breaker with a 

rated tripping current not exceeding 

30mA

 be installed. 

Check the pumps name plate for the following: voltage, amp draw and cycle. 

The power cord, including the ground wire shall have a quality of 

245 lEC66 (HO7RN-F)

 for models 

greater

 than 

1Kw  

power input. 

For models less than 

1Kw 

input the quality shall be of 

245 IEC57 (HO5RN-F)

. All installations must comply with local codes, 

based on 

IEC 364-7-702

 requirements. 

Содержание Aquaspeed 0.5hp

Страница 1: ...ould result in property damage serious injury or death Improper installation will void the warranty Notice to Installer This manual contains important information about the installation operation and safe use of this product Once the product has been installed this manual must be given to the owner operator of this equipment WARNING AQUASPEED ...

Страница 2: ...followed including the following Read Follow All Instructions First WARNING Do not permit children to play with this product A qualified electrician must carry out all electrical wiring in accordance with local electrical regulations Before working on any motor be certain that the electrical source is switched off AQUASPEED ...

Страница 3: ...e installed in accordance to the local codes 7 The motor must be grounded 8 The weight of the plumbing and fittings is to be independently supported and not carried by the pump 9 The pump motor cooling fan must have a minimum clearance of 150mm Important Electrical Notice The electrical installation is to be done by a licensed electrician Each pump requires a circuit breaker to separate the pump f...

Страница 4: ... for approximately 1 second If it is running in the wrong direction turn off power and interchange any 2 wires and repeat the above step to check When installing three phase pumps a separate device must be available for permanent installation This is so the pump can be isolated from the mains power A contact distance of 3mm per pole is required for both three phase and single phase units Motor pro...

Страница 5: ...minutes for the pump to start delivering water WARNING High suction lift or long suction lines will require additional time to prime and can severely affect the performance of the pump If the pump will not prime flow repeat steps 1 and 2 above WARNING If allowed to run dry mechanical seals can be damaged rapidly and may need to be replaced ENSURE that there is always adequate water in the hair and...

Страница 6: ...n to ensure the pump is protected from damage It is recommended that if the pump is not used during this winter period it should be drained completely A drain plug is provided for this purpose Do not replace the drain plug Store it in a safe place until you require the use of the pump An example would be within the hair and lint pot bowl basket If at all possible remove the pump away and store it ...

Страница 7: ...erformed on each pump or on the equipment connected to it after disconnecting them from the mains power and after disconnecting the starting device 6 The user should make sure that assembly and maintenance tasks are carried out by qualified authorised persons and that these persons have first carefully read the instructions for service and installation 7 The operating safety of the pump is only gu...

Страница 8: ...and that starting devices have been locked 5 It is advisable to follow the steps listed below before handling the pump in any way a Turn off the voltage to the pump b Lock starting devices c Verify that there is no voltage in the circuits including ancillary devices and auxiliary circuits d Wait until motor stops completely The above list should be considered indicative and not binding for the pur...

Страница 9: ...l overload protector will function to turn them off if there is an overload or high temperature problem The pump motor cooling fan must have a minimum clearance of 150mm Shield from the weather Do not tightly cover or enclose motor 5 NOISY PUMP OPERATION Worn bearing Air leak in suction Suction blockage Foreign matter in impeller Cavitations Have electrician replace See 1 Locate and clear blockage...

Страница 10: ......

Страница 11: ......

Страница 12: ... 01993 777200 info certikin co uk www certikin co uk CERT19 Certikin International Ltd Witan Park Avenue 2 Station Lane Industrial Estate Witney Oxfordshire OX28 4FJ UK AQUASPEED ...

Отзывы: