fghj
7
CBX
LED indication
Red
Yellow
Green
Status
CBX Start Up, Light Test
Standby, waiting for next sample cycle
Configuration or Setup Mode
Sampling
Configuration or Setup error, check parameters
Mechanical or Electrical Problem
Cold Temp, less then 36ºF inside the unit.
Shut down the CBX to alleviate cold weather damage
Fig 1
Operation
All configurations are done via BB1/BB2 that is connected to the CBX. All settings shall
be done and saved (done by exiting the menu) before a new sampling is preformed.
Depth and concentration is shown on the BB1/BB2 on-‐line during a sampling cycle.
CBX Mode
There is two different modes the CBX can be set to,
Setup
and
Trig
.
Trig
is the normal working mode. In this mode the CBX will take a sample on every
external trig from the rake limit switch.
Setup
, the CBX must be set to this mode before changing calibration parameters or
using “
MANUAL UP/DOWN
” button.