Exterior of the product is a petroleum-based product and should not be 
exposed to organic solvents such as acetone, ballpoint pen, gasoline, thinner, 
sweat, hair mousse or hair spray.

1

Where there is direct contact with the head or skin, wipe with a dry cloth.

If there is contact with cosmetic products or volatile emulsions and is left
for a long time, the surface may peel off so wipe with a dry cloth as soon as.

When washing outer fabric, make sure to hand wash separately with
a neutral detergent.

If there is contact with hot objects or heat, the leather will curl up so 
please use caution.

Avoid wearing clothes that may cause stains when using the product.
(Please be careful as there is a risk of contamination caused by external friction.)

Avoid direct sunlight and humidity and store at room temperature.
(It causes discoloration and aging of the product.)

Please do not twist the remote control cable.

2. Maintenance and Storage

Q : Is the power switch on the bottom
     of the product on?

Q : Is the power cord connected properly?

A : Turn on the power switch.

A : Connect the power cord again.

Q : Are the abdominal vibration projector
     connected properly?

A : Connect the abdominal vibration projector
     properly. 

A : Internal projectors can be moved using
     the up/down key only in intensive mode,
     semi-automatic mode, manual mode.

Q : Can you move the internal projectors
     using the up/down key?

A : Check the condition of the supporting mat.

     Some of the remote control keys cannot be

     operated if the supporting mat is not  

     completely opened.

Q : Can some of the remote control
     keys be operated?

A : Make sure the power cord is plugged in.
     Make sure the remote control is powered on.

Q : Is the supporting mat fully closed?

Are the diagnosis code messages displayed on the remote control?

Q : Is a sound source in a USB device
     not playing back?

A : It takes time for the product to recognize
     a USB device. Check if it is connected
     correctly, wait, and try again.

A : Is there a playable sound source stored in USB?
     Please check.

Q : Are the diagnosis code messages
     displayed on the remote control?

A : After checking the diagnosis code messages,
    contact the customer support center.  
    Never dismantle the product arbitrarily.

Does the remote control turn on?

Is the product malfunctioning?

The the abdominal vibration projector do not operate.

Is the air massage mode not working?

A : Be careful not to twist or fold the air hose.

Q : Is the air hose not twist or fold?

3. Troubleshooting

Why is the USB not recognized?

Customer Support Center 

CERAGEM INTERNATIONAL INC.
LOS ANGELES, CA 90010

3699 WILSHIRE BLVD. STE 930

213-480-7070

Содержание CGM MB-1701

Страница 1: ...E6N0N107030 JAN 13 22 CGM MB 1701 User Manual E358148 10 Jeongja 1 gil Seonggeo eup Seobuk gu Cheonan si Chungcheongnam do 31045 Korea Tel 82 41 523 2550 Fax 82 41 523 2560...

Страница 2: ...Please follow the instructions carefully in order to reduce potential electric shocks Unintended use may cause burns or physical harm Warnings and safety information This appliance is not intended for...

Страница 3: ...er defibrillator other artificial implants or other medical devices consult with your doctor prior to use If you have sensitive reactions or allergy to heat you should also consult your doctor before...

Страница 4: ...sing the product in the abdominal area avoid using it in the rib area 32 This product is not a processed product under the act on Protective action guidelines against radiation in the natural environm...

Страница 5: ...and preparation 11 Using the Master V6 17 2 Remote control layout 3 Using the remote control 4 Moving the product 1 Before using the product 1 User checklist Before After use procedure 2 Maintenance...

Страница 6: ...ssage that fits the body condition through 17 automatic modes semi automatic mode manual mode and master mode Head cushion Outer fabric Supporting mat Heating element applied part Remote control Wired...

Страница 7: ...10 MEMO 11 1 Check product components 2 Before installation 3 Installation 4 After installation Installation and preparation...

Страница 8: ...dy and used on the abdomen Main body Use it lying down as a device that helps relieve muscle pain Remote control Used to check the product functions and operating condition of the product Remote contr...

Страница 9: ...he correct temperature for each user 2 Sit on or use the product after opening the supporting mat to its end Turn on the power located at the bottom of the main body Remove the film from the LCD and t...

Страница 10: ...7 16 Caution When using the air massage do not sit on or lean against the supporting mat Be careful not to fold the air hose Product failure may occur When assembling the air cell massager insert it i...

Страница 11: ...n may not appear on the remote control screen This is not a product failure Press the mode start button and use the product immediately Wait Abdominal vibration projector connection Wait Before using...

Страница 12: ...e Ceragem sound USB Bluetooth Voice guidance Sound pause 3 2 Display of speed of the internal projector low speed constant speed high speed 1 4 5 Internal projector location 6 7 8 9 Internal projector...

Страница 13: ...Yellow Select Whole temperature 55 3 sphere projector Delete speed Stored music 5 Volume 5 Bodyicon supporting mat Yellow Select Whole temperature 55 3 sphere projector Delete speed Stored music 5 Vo...

Страница 14: ...utomatic mode the internal projector speed will be displayed allowing you to set the internal projector speed speed setting is not available in some modes Low speed Constant speed High speed Off 86 14...

Страница 15: ...hen any external sound source is connected Voice guidance activation deactivation If a USB is connected but there is no sound source the icon will not be displayed If Bluetooth or USB are connected th...

Страница 16: ...p down buttons to cycle through modes 1 3 2 To initiate the abdominal vibration projector click the appropriate icon and press the start pause button Caution Do not operate the abdominal vibration pro...

Страница 17: ...he Main mode is paused the air massage will be paused also and will not resume when the main massage begins It is necessary to re start the air massage separately When massage is paused while using th...

Страница 18: ...ately 18 minutes Mode 16 Meditation Breathing Approximately 36 minutes and 30 seconds Mode 10 Stretching Mode 2 Relax Mode 4 Circulation Mode 6 Energy Mode 8 Rest Mode 13 Meditation Golf Mode 15 Medit...

Страница 19: ...lumbar vertebrae Position Screen display 24 segments C1 7 T1 12 L1 5 35 34 Approximately 60 minutes Duration of mode Approximately 60 minutes Duration of mode 3 The manual mode will begin at the chose...

Страница 20: ...hen 60 minutes have passed after operating the remote control the remote control will turn off automatically and the mode will end The remaining time is displayed at the upper left corner of the scree...

Страница 21: ...oduct Close the supporting mat and unplug the cable of the abdominal vibration projector from the main body 1 2 Turn off the remote control after closing the supporting mat If you close the supporting...

Страница 22: ...41 40 1 User Checklist Before After use procedure 2 Maintenance and storage 3 Troubleshooting 4 Diagnostic codes 5 Product specifications Maintenance and troubleshooting MEMO...

Страница 23: ...f time Auxiliary parts A loud sound occurs when I spread the supporting mat It is a normal operating noise that occurs in adjusting the height of the supporting mat to the height of the main body when...

Страница 24: ...jector properly A Internal projectors can be moved using the up down key only in intensive mode semi automatic mode manual mode Q Can you move the internal projectors using the up down key A Check the...

Страница 25: ...e 9 years Connection to wireless communication may be limited due to the distance between devices speed obstacles or other wireless devices Maximum Permissible Weight 298lbs MP3 WAV Playable files Env...

Страница 26: ...1 Explanation of mark delivery and storage 2 Attached documents Service manual 49 48 MEMO...

Страница 27: ...ange UL Classification Mark Medical General Medical Equipment E358148 AS TO ELECTRICAL SHOCK FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH ANSI AAMI ES60601 1 2005 AMD 1 2012 CAN CSA C22 2 NO 60...

Страница 28: ...n the electromagnetic environment specified below The customer or the user of CGM MB 1701 should assure that it is used is such an environment Immunity test Compliance level IEC 60601 test level Elect...

Страница 29: ...situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Note 2 It is essential that the actual shielding effectiveness and filter attenuatio...

Отзывы: