11
SECTION 2.0 CHIMNEY (FLUE SYSTEM)
2.1 DEFINITIONS
For clarity, the following definitions should be used with respect to these instructions:
•
A
chimney system
consists of a
connector
off the top of the stove, and a
chimne
y
, which
attaches to the connector and terminates outside the house.
•
A
chimney
can be a
masonry chimney
(of masonry construction with an inside liner), or a
factory built chimney.
•
A
factory built chimney
can be a
double wall chimney
(two concentric pipes with insulation
- sometimes referred to as an insulated
solid pack
) or an
air cooled chimney
(three
concentric pipes, with insulation between the first and second pipes, and air between the
second and third pipes).
•
A
single wall
connector is a single pipe.
•
A
double wall
connector has two concentric pipes, no insulation, and is an
air cooled
connector.
2.2 CHIMNEY
CAUTION:
•
DO NOT fill any framed space around the factory-built chimney with insulation or any other
material. Insulation placed in this area could cause adjacent combustibles to overheat.
•
Do not use makeshift compromises during installation as they may be safety hazards, and a
fire could result.
•
Do not connect this unit to a chimney system serving another appliance.
•
Do not cut rafters or ceiling joists without first consulting a building official to ensure
structural integrity is not compromised.
Your wood stove may be hooked up with a factory built or masonry chimney. If you are using a
factory built chimney, it must comply with UL103 (USA) or ULCS629 (Canada) standards. It must
therefore be a 6” (152mm) HT Type (2100°F) chimney. It is extremely important that it be installed
Содержание 45398A
Страница 4: ...3 5 2 FW2470 43 5 3 FW2700 44 5 4 FW3000 45 CENTURY HEATING LIMITED WARRANTY 46 ...
Страница 20: ...19 Typical installation through the ceiling FIGURE 2 2 1 B Typical Installation Through the Ceiling ...
Страница 26: ...25 FIGURE 2 2 2 B Factory Built Thimble ...
Страница 27: ...26 FIGURE 2 2 2 C Brick Thimble ...
Страница 29: ...28 FIGURE 2 3 B Minimum Slope Avoid 90 degree eblows We recommend that you use two 45 degree elbows instead ...