20
20
4mm
CABLE
2
CONTROLLER
MODEL
CP77
F
G
+
-
-
BATTERY
12V
NOTE: IF A LARGE BATTERY IS USED, THE CABLES
CONNECTING THE BATTERY TO THE CP80 CARD
SHOULD BE BETWEEN 6 & 10 mm
²
FOR CABLE
LENGTHS LESS THAN 5 METRES.
+
13.2 Connecting Battery
CP4 BATTERY
CP77
13.3 Control Card Setup
1
1
1
2
3
4
1
16
2
SWITCH NO
3
4
DESCRIPTION OF OPERATION (MODE)
GREEN POWER ON LED
(ON WITH MAINS POWER PRESENT)
GATE STATUS
LED (RED)
0
1
0
0
0
0
1
1
LEVER MOTOR(S) WITHOUT AUTOCLOSE
LEVER MOTOR(S) WITH AUTOCLOSE
5 SECS
SEE PAGE 20
45 SECS
LED
GATE STATUS
STATUS LED TABLE
GATE CLOSED
LED OFF
LED ON
FAST FLASH
SLOW FLASH
2 FLASH/2 SECS
3 FLASH/2 SECS
MAINS FAILURE
BATTERY LOW
OPENING
CLOSING
GATE OPEN
AUTOCLOSE TIMER
COLLISION SENSITIVITY
x
x
x
x
x x
x x
x x
x
IDENTIFY STATUS LED WHICH WILL GIVE INFORMATION ON GATE STATUS (e.g. WHETHER GATE
SHOULD BE OPEN OR CLOSED).
SELECT DIP SWITCH SETTINGS TO GIVE REQUIRED MODE OF OPERATION.
SELECT "AUTOCLOSE" IF REQUIRED (USE SW1).
SET AUTOCLOSE TIMER POTENTIOMETERS TO MINIMUM INITIALLY AND ADJUST TIME TO SUIT AFTER
COMMISSIONING.
SET COLLISION SENSITIVITY POTENTIOMETERS TO MID POSITION (SEE PAGE 20 FOR CORRECT FINAL
ADJUSTMENT).
COMMISSIONING INSTRUCTIONS
CP77