background image

17

17

PLUG IN TRANSFORMER IN HOUSE

ENCLOSURE MOUNTED CHARGER TRANSFORMER MOUNTED AT GATE

OPTION 1

AC

AC

CONTROL BOX

OPTION 2

1,5mm ²

CABLE

CONTROLLER

MODEL

BROWN

BROWN

CP77

15

16

AC

AC

AC

AC

220V AC

PLUG IN OR

ENCLOSURE

MOUNTED

NOTE: SOLENOID LOCK, OR MAGNET, IS USED TYPICALLY
ON SINGLE SWING GATES

OPTION 1

SOLENOID

LOCK

MAGNETIC

LOCK

OR

OPTION 2

Min. 1,5mm²

CABLE

MAGNET SUPPLY

(Could be +12V from gate motor battery

depending on type of magnetic lock used)

CONTROLLER

MODEL

CP77

14

13

SOL

+12V

SOL

12V RELAY

COIL

COM

N.C.

SOL

+12V

+12V

N

S

}}

L

N

E

L

N

E

220V AC
SUPPLY

PLUG IN

CONNECTOR

CP53

CP13E

12.12 Solenoid Lock/Magnetic Lock

12.13 Battery Charger Transformer Supply

Содержание LEVER4

Страница 1: ...Latest Revision 07 11 2006 Document Ref 1110 D 01 0001_5 LEVER Swing Gate Operator INSTALLATION MANUAL...

Страница 2: ......

Страница 3: ...er 4 kit with CP77 controller 220V supply at gate Single Lever 5 kit with CP77 controller split charger low voltage at gate Double Lever 4 kit with CP77 controller split charger low voltage at gate KI...

Страница 4: ...890 944 949 1057 1043 1009 114 114 125 151 151 151 919 919 935 972 972 972 120 120 120 120 120 120 GATE OPENING ANGLE B MIN 70 WALL A C 3 0 Recommended Tools MASONRY BITS 6mm 20mm FOR WALL MOUNT STEEL...

Страница 5: ...REMOTE RECEIVER PEDESTRIAN KEYSWITCH INFRA RED BEAM SOLENOID STRIKE not shown SOLAR PANEL not shown G P GENERAL PURPOSE HOUSE WIRING OR PANEL FLEX WHEN LAYING NORSK UNDERGROUND PLEASE NOTE 1 CABLE BU...

Страница 6: ...SHOWN CLOSED STEP 1 MEASURE 1M ALONG GATE MAKE MARK S1 ON THE GROUND 6 0 Mount Control Box REMOVE CHASSIS PLATE MOUNT ENCLOSURE TO WALL DRILL CABLE ENTRY HOLES REPLACE CHASSIS PLATE AND WIRE EQUIPMEN...

Страница 7: ...S1 x x S1 S1 x x S2 S2 STEP 3 MEASURE DISTANCE Z BETWEEN S1 S2 IN mm STEP 2 SWING GATE TO DESIRED OPEN POSITION 70 120 DEGREES MAKE SECOND MARK S2 ON THE GROUND Determine gate opening angle continued...

Страница 8: ...0 247 226 206 188 171 155 140 125 994 983 971 958 944 928 925 923 921 920 919 970 963 958 953 949 945 942 940 938 936 935 A A A B B B C C C BETA LENGTH OF GATE LEAF L metres 1 0 L 1 5 1 5 L 2 0 2 0 L...

Страница 9: ...F GATE BRACKET RAWLBOLT OR WELD SECURELY TO PILLAR 1 2 7 3 Mount Actuator Brackets 1 2 3 4 5 GATE BRACKET LEVEL LINE TOP SIDE OF PLATE C 1 7 7 A B 3 PLAN VIEW B A C C 7 CUT REAR MOUNTING PLATE TO LENG...

Страница 10: ...117 109 100 234 215 200 184 171 158 146 135 125 115 106 994 983 971 958 944 928 925 923 921 920 919 970 963 958 953 949 945 942 940 938 936 935 A A A B B B C C C BETA LENGTH OF GATE LEAF L metres 1 0...

Страница 11: ...7 1732 LEVER 5 SMA LEVER 5 DMA Z 70 75 80 85 90 95 100 105 110 115 120 120 130 140 151 163 176 189 204 250 246 243 146 145 144 142 139 137 135 133 141 130 119 1100 1090 1080 1069 1057 1044 1030 1015 9...

Страница 12: ...OOF LEAVE A LOOP IN MOTOR CABLE BETWEEN JUNCTION BOX AND ACTUATOR JUNCTION BOX JUNCTION BOX CONTROLLER ENCLOSURE 3 4 10 0 Mount Actuator 2 1 3 4 TO OPERATE GATE IN MANUAL OVERRIDE MODE REMOVE BOOT UTI...

Страница 13: ...G CONTROLLER WITH MULTIPLE FEATURES INFRA RED BEAM REMOTE STATUS LED LIMIT SWITCHES NOT USED PILLAR LIGHT OVER RIDE AUTO CLOSE CONTROL 12V DC 3A AUX SUPPLY SOLENOID STRIKE FREE EXIT LOOP NORMAL TRIGGE...

Страница 14: ...NEG PED 0 2mm CABLE 2 CONTROLLER MODEL 2 POSITION SWITCH CP77 13 2 C 12 4 Holiday Lockout OR OR PUSHBUTTON KEYPAD 1 4 7 8 9 5 6 2 3 12V NEG COM N O NEG LOCK LATCH TYPE RADIO RECEIVER RELAY MUST HAVE...

Страница 15: ...onsult intercom manufacturer for full wiring diagrams CONTROLLER MODEL CP77 13 C 3 12V NEG TRG 12V 12V NEG NEG TRG TRG E C A B D TRG 12V RECTIFIER RELAY N C N O NEG DP 2RN OR DP 2SN HOUSE TELEPHONE DR...

Страница 16: ...RADIO RECEIVER CENTURION SMART RX EXAMPLE 2 EXAMPLE 1 TRG TRG 12V 0 2mm CABLE CONTROLLER MODEL CP77 4 C OUT NEG N E S S R P S E R Q E F EH C O D E V I LE L OP ET CT OR D 0 L 1 0 WA RN IN G o N t pe n...

Страница 17: ...0 2mm CABLE CONTROLLER MODEL CP77 AUTOCLOSE TOGGLE C 6 12 9 Remote Pillar Light Control LIGHT NEG AUTO CLOSE TOGGLE TO MOTOR CONTROLLER SIGNAL COMMON TOGGLE SWITCH IS SHOWN FITTED TO AN INTERCOM TELE...

Страница 18: ...ES 2 sec GATE CLOSED OFF GATE OPENING SLOW EVEN FLASH MAINS LOSS 2 FLASHES 2 sec COLLISION DETECTION 4 FLASHES 2 sec GATE OPEN ON GATE CLOSING FAST EVEN FLASH 12 11 Safety Beam Infra Red Beam BEAM N O...

Страница 19: ...SOLENOID LOCK OR MAGNET IS USED TYPICALLY ON SINGLE SWING GATES OPTION 1 SOLENOID LOCK MAGNETIC LOCK OR OPTION 2 Min 1 5mm CABLE MAGNET SUPPLY Could be 12V from gate motor battery depending on type o...

Страница 20: ...NS SUPPLY EARTH SYSTEM AT THE GATE USING A COPPER EARTH SPIKE ENSURE THAT SYSTEM IS CONNECTED TO ESCOM OR MAIN EARTH 12 14 Pillar Light s 12 15 Recommend Earthing for Lightning Protection CP77 CONNECT...

Страница 21: ...CONTROLLER GREEN POWER SUPPLY CONNECTED AND SWITCHED ON x x CP77 CONTROLLER GREEN POWER SUPPLY CONNECTED AND SWITCHED ON 13 0 COMMISSIONING 13 1 Applying Mains Power L N E L N E 220V AC SUPPLY PLUG IN...

Страница 22: ...S SEE PAGE 20 45 SECS LED GATE STATUS STATUS LED TABLE GATE CLOSED LED OFF LED ON FAST FLASH SLOW FLASH 2 FLASH 2 SECS 3 FLASH 2 SECS MAINS FAILURE BATTERY LOW OPENING CLOSING GATE OPEN AUTOCLOSE TIME...

Страница 23: ...NTROLLER CLOSING ADJUST SENSITIVITY ON CONTROLLER SUCH THAT GATE S WILL OPEN AND CLOSE RELIABLY BUT NOT CAUSE DAMAGE TO PERSONS OR OBJECTS IN THE PATH OF THE GATE S MOTOR WILL JUST STOP WHEN GATE HITS...

Страница 24: ...Tel 9 380 4020 BILLY GATES CANADA Tel 250 334 1553 ABA GATES WESTERN AUSTRALIA Tel 8 933 03061 DOMINATOR SYSTEMS NEW ZEALAND Tel 3 384 5145 ICBT VICTORIA Tel 3 933 54213 ROTECH QUEENSLAND Tel 7 326 47...

Отзывы: