Specifications

Pressure Range .....................................................   -199 mm to +999 mm Hg

Compass MAP Output ...........................................   25 μV per mm Hg

Accuracy: Compass LCD .......................................   ±2 mm Hg below 50 mm Hg

 

±3% of reading above 50 mm Hg

Accuracy: Compass MAP ......................................   ±2% below 50 mm Hg

 

±3% of reading above 50 mm Hg

Zero Drift ...............................................................   ±1 mm Hg per 4 hours

Operating Life .......................................................   > 8 hours 

Operating Temperature .........................................   15° to 40°C (59° - 104°F) 

Storage Temperature ............................................   -29° to 49°C (-20° - 120°F)

Light Sensitivity .....................................................   < 1 mm Hg

Lithium Ion Battery Voltage ...................................   3 Volts

Display

+ symbol for positive pressure 

-  symbol for negative pressure

Bar 1 =

1 mm Hg

Bar 12 =

12  mm Hg

Bar 36 = 149 mm Hg

Bar 18 = 42 mm Hg

Pressure Unit = mm Hg

Numerical Display Modes:
• Display updates 2 times/sec

Graphical Waveform:

Variable scaling to enhance
physiologic pulsation

Bars 1–12: 1  mm Hg/bar
Bars 13–18: 5 mm Hg/bar
Bars 19–36: 6 mm Hg/bar

Compass CAST FCCID: 2AF4Z-CWHG001
Compass MAP FCCID: 2AF4Z-CWM001

Содержание Compass Cast

Страница 1: ...abled physiological pressure transducer with integrated digital display The Compass Monitor Accessory Plug Compass MAP receives the wireless pressure signal from the Compass Cast and inputs the pressu...

Страница 2: ...our seconds to indicate that it is scanning for a compatible Compass Cast 5 Zero the pressure signal on the patient monitor per the monitor s IFU 6 Remove Compass Cast from its sterile package 7 Remov...

Страница 3: ...it to atmospheric pressure and then cycle device power it off and then power back on to recalibrate To Power Off and Recalibrate Press and hold button for two seconds until is displayed on the LCD Fi...

Страница 4: ...he application attach accessory e g flushing syringe stopcock extension or IV tubing etc to the proximal female luer lock port of the Compass Cast per hospital protocol Figure 3 5 Depending on the app...

Страница 5: ...power off the device To recalibrate depress the power button for approximately one second until the LCD reads 00 7 If procedure warrants insert guidewire up to 0 038 diameter through the Compass Cast...

Страница 6: ...mm displayed will change from flashing to off The device must be power cycled for it to restart advertising for a wireless connection Once a Compass MAP has established a wireless connection to a Com...

Страница 7: ...104 F Storage Temperature 29 to 49 C 20 120 F Light Sensitivity 1 mm Hg Lithium Ion Battery Voltage 3 Volts Display symbol for positive pressure symbol for negative pressure Bar 1 1 mm Hg Bar 12 12 m...

Страница 8: ...or Pressure values outside operating range Lb3 Less than 8 hours battery life remaining Lb2 Less than 6 hours battery life remaining Lb1 Less than 4 hours battery life remaining Lb0 Less than 2 hours...

Отзывы: