5.4.  Beep-On-Activation

Beep-on-activation is a special feature associated with multichannel receiver variants. 

It is a configurable feature that, if enabled, activates the buzzer on any press of a 

transmitter button that is learnt into memory. The feature is disabled on all multichannel 

receiver variants by default. To enable the feature refer to the section, Configuring the 

Special Features, on page 27.

The buzzer provides one short, 150ms beep when a valid button that is learnt into 

memory is pressed.

Panic channels override the beep-on-activation feature. This means that if a button is 

pressed, that is associated with a channel, or combination of channels, where at least 

one of the channels is a panic channel, the buzzer will not beep.

It is possible to disable the functionality associated with jumpers J1 and J2. Receivers are 

often placed in elevated environments to optimise the range of the receiver. Often, little 

or no attention is paid to securing the receiver. If the receiver unit is not secured it is 

possible for a perpetrator to access the jumpers on the receiver and learn a remote into 

the system without the knowledge or consent of the user. The Nova Helix range includes 

functionality to disable the jumpers. With a master remote, the jumpers may be re-

enabled at any stage.

The following procedure documents disabling the jumper interface on the Nova Helix 

range of receivers.

1.  At least one master transmitter must be learned into the receiver memory.
2.  Press and hold a master button for between 20 and 30 seconds. This will cause the 

receiver to enter demastering mode.

3. 

While in this mode, fit jumper J2. The status LED will illuminate while the jumper 

remains bridged.

4.  When jumper J2 is removed, both jumpers will be disabled and no further jumper 

operations may be performed.

To re-enable the jumper interface, repeat steps 1 through 4 again.

As a special note, the following system locks are possible:
•  Disabling the jumper interface
•  Demastering all remotes in memory (thereby rendering any further master based 

learning impossible)

It is, however, not possible to have both system locks in place indefinitely. 

On every power cycle of the Nova Helix receiver, the memory is interrogated to establish 

whether any masters exist in memory. If no masters exist, and the jumper interface 

has been disabled, then the jumper interface is forcefully re-enabled. Once the jumper 

interface is re-enabled it is possible to administrate the system again.

6. Disabling Jumpers J1 and J2

DIS

ABLING

 JUMPERS

 J

1

 A

ND

 J

2

S

ECTION

 6

Содержание Nova Helix

Страница 1: ...Nova Helix Operation Manual Centurion Systems Pty Ltd www centsys com r e c e i v e r...

Страница 2: ...without obligation to notify any persons of any such revisions or changes Additionally Centurion Systems Pty Ltd makes no representations or warranties with respect to this manual No part of this docu...

Страница 3: ...ation 5 2 Simultaneous Primary Channel Activation 5 3 Non Volatile Latches Sticky Latches 5 4 Beep On Activation 6 Disabling Jumpers J1 and J2 7 Configuring the Special Features 8 SmartSwitch II Inter...

Страница 4: ...ivation settings for all channels These settings include enabling disabling latching and panic functionality In addition it is possible to adjust the pulse time on pulsed channels with the following p...

Страница 5: ...the physical output but is a convenient way to describe the collective functionality that a transmitter activates As an example consider the case in Figure 2 A multichannel receiver is used to control...

Страница 6: ...ividually the channels are configured with the following activation settings Channel 1 has a one second pulse time Channel 2 has a four second pulse time Channel 4 is a latching channel When the chann...

Страница 7: ...annel jumpers behave differently when discussing the SmartSwitch II interface The jumpers are used to select a 4 bit binary address that addresses a particular SmartSwitch II device on the interface b...

Страница 8: ...3 Channel 8 8 4 Channel 9 9 1 4 Channel 10 10 2 4 Channel 11 11 1 2 4 Channel 12 12 3 4 Channel 13 13 1 3 4 Channel 14 14 2 3 4 Channel 15 15 1 2 3 4 TABLE 2 CHANNEL JUMPER TO SMARTSWITCH II DEVICE MA...

Страница 9: ...accessible through the learning interface four channel jumpers hence 15 channels but none of the channels are primary channels The single channel variants have one primary channel channel 1 and cannot...

Страница 10: ...ation in particular the LED on the receiver will begin to flash slowly the buzzer will emit a short double beep and the channel functionality will activate 6 The button can be released once the learni...

Страница 11: ...button is pressed refer to points 6 a and 6 b below for further clarification c The button learning process is not finalised 5 Once the three second period has elapsed the LED will turn on again and...

Страница 12: ...on presses 6 While the receiver is in demastering mode any mastered button that is pressed for three or more seconds but less than 10 seconds and is associated with the functionality that the receiver...

Страница 13: ...the button is released in this window it will simply be demastered refer to the previous section Demastering Buttons for further information on this operation b Do nothing because the button being de...

Страница 14: ...to the specified channel Learns a button to the default channel channel 1 Autolearn Mode Channel Specified No Channel Specified Bulk Demaster Channel Bulk Demaster All J2 Memory Blank Memory Non Blank...

Страница 15: ...on has been demastered it can be remastered There are two methods to achieve this 4 2 1 Link Learn Remastering 1 To remaster a remote start by entering link learn mode For reference follow steps 1 and...

Страница 16: ...and that the button is a demastered button Refer to Appendix A on page 30 for a description of the LED and buzzer feedback 6 Once the demastering period has elapsed minimum three seconds the LED will...

Страница 17: ...le This table will be used for all buttons learned into memory during the actual Autolearn procedure Autolearn mode is also limited to a maximum of 7 days before it times out This prevents a user from...

Страница 18: ...an example of the Autolearn configuration procedure 8 Once the association table has been finalised remove jumper J1 This confirms the mapping and enters Autolearn mode The buzzer will beep four time...

Страница 19: ...ettings Memory Erase operation is performed Table 5 documents the settings that are erased in each of the erase cases Channel Erase Transmitter Memory Erase Settings Memory Erase Clears channel compar...

Страница 20: ...4 Holiday lockout or equivalent bi stable function Channel 15 Duress or alarm panic activation Simultaneous Activation Sticky Latch Beep On Activation Special Feature Setting Enabled Enabled Disabled...

Страница 21: ...ntire Transmitter Memory space Resets latch settings on channel 1 Resets panic settings on channel 1 Restores default relay pulse time Clears the SmartSwitch II device output that may be active in the...

Страница 22: ...n channel jumper C1 only To set channel 11 a SmartSwitch II device output place links on channel jumpers C1 C2 and C4 the binary combination of C1 C2 and C4 that results in 11 b 1011 Proceed as per th...

Страница 23: ...ed to step 10 9 After the three second window the LED will switch off and start flashing once per second Counting LED flashes or using a watch to keep track of the number of seconds that pass will det...

Страница 24: ...ature on all receiver variants that allows the receiver to restore its output state on power loss When power is restored the output will assume the state it last reflected prior to the receiver losing...

Страница 25: ...er to set its output to the output state of the receiver s channel prior to power loss SmartSwitch II device restores its output state when its power is restored Subsequently assuming power is restore...

Страница 26: ...f the user The Nova Helix range includes functionality to disable the jumpers With a master remote the jumpers may be re enabled at any stage The following procedure documents disabling the jumper int...

Страница 27: ...e is to be configured Channel jumpers 3 and 4 determine which of the special features is being configured Linking function jumpers J1 or J2 determines whether the special feature being configured is b...

Страница 28: ...is important is that the devices share the same ground rail Up to 15 SmartSwitch II devices can be wired in a daisy chained bus configuration to the receiver SmartSwitch II devices are addressable Eac...

Страница 29: ...r would like to distribute multiple items garden lights for example in physically different areas but have all of them respond to the same remote control button activation The network is limited to 15...

Страница 30: ...3 Second Learn Period Button Released Button Pressed 3 Second Learn Period Button Released Button Pressed 3 Second Learn Period Button Released Button Pressed 3 Second Learn Period Button Released Ma...

Страница 31: ...ttons are pressed the Any Button property is removed from Ch 2 and shifted to Ch 6 when the Ch 6 jumper setting is configured on the Channel Jumpers Ch 1 Ch 2 Ch 3 Ch 4 Closed Ch 5 Ch 6 But 3 Ch 7 Ch...

Страница 32: ...signal and captures the transmit ter information The receiver logic processes the button transaction and determines that channel 3 must be activated The signal splitter in the output logic block rout...

Страница 33: ...page 33 www centsys com NOTES Notes...

Страница 34: ...page 34 www centsys com Notes NOTES...

Страница 35: ...page 35 www centsys com NOTES Notes...

Страница 36: ...16h30 GMT 2 E OE Centurion Systems Pty Ltd reserves the right to change any product without prior notice All product and brand names in this document that are accompanied by the symbol are registered...

Отзывы: