9.2.  Example Autolearn Configuration Procedure

Ch.1

Ch.2

An

y But.

Ch.3

Ch.4

Closed

Ch.5

Ch.6

Ch.7

Ch.8

Closed

Ch.9

Ch.10

Ch.11

Ch.12

Ch.13

Ch.14

Ch.15

Closed

The system enters 

A

utolearn 

Mode 

with 

Ch.2 selected. Note 

that Ch.4, 8 and 

15 are all closed 

because there 

are buttons that 

are already learnt 

into those channel 

compartments.

Once jumper J2 

is re

mo
ved, 
the 
sys
-

tem exits A

utolearn 

configur

ation

 

mode, and enters 

A

utolearn Mode 

proper

. The associa

-

tion table is r

ation

-

alised

 to

 reflect

 only
 

the buttons that will 

be accepted during 

A

utolearn, and the 

channels they will 

be associated with 

(activ

ate) when 

they are pressed. 

This

 A

urolearn

 configur

ation

 timeline

 illustr

ates

 a

 typical

 example

 of

 an

 A

utolearn

 configur

ation

 procedure.

 Before

 entry

 into
 A

utolearn,

 buttons

 (one

 or

 sev
er

al)

 are
 learnt

 into
 channels

 4,

 8

 and
 

15.
 A

utolearn

 Mode

 is

 entered

 on

 Channel

 2

 in

 the
 example.

 Once

 in

 A

utolearn

 configur

ation,

 the
 steps

 follow

 sequentially

 from

 left
 to

 right

 (as
 per
 the
 timeline

 at

 the
 top
 of

 the
 page).

 When

 

Jumper

 J2

 is

 remo

ved

 (in
 the
 last
 step
 on

 the
 right),

 the
 receiv

er

 enters

 A

utolearn

 Mode

 for
 a

 period

 of

 7-da

ys.
 Only

 buttons

 that
 are
 configured

 in

 the
 configur

ation

 section

 will
 be

 accepted

 once

 

in A
utolearn.

Ch.1

Ch.2

Ch.3

Ch.4

Closed

Ch.5

Ch.6

An

y But.

Ch.7

Ch.8

Closed

Ch.9

Ch.10

Ch.11

Ch.12

Ch.13

Ch.14

Ch.15

Closed

Since no buttons 

are pressed, the 

An

y Button propert

is remo

ved from 

Ch.2 and shifted 

to Ch.6, when the 

Ch.6 jumper setting 

is

 configured

 on

 the
 

Channel Jumpers. 

Ch.1

Ch.2

Ch.3

Ch.4

Closed

Ch.5

Ch.6

But. 3

Ch.7

Ch.8

Closed

Ch.9

Ch.10

Ch.11

Ch.12

Ch.13

Ch.14

Ch.15

Closed

As soon as an

button is pressed, 

the An

y Button 

propert

y is remo

ved 

and nev

er restored 

during the current 

A

utolearn session. 

The system will 

accept the last 

button pressed (and 

the tr

ailing edge 

tr

ansaction of that 

button press).

Ch.1

Ch.2

Ch.3

Ch.4

Closed

Ch.5

Ch.6

But. 3

Ch.7

Ch.8

Closed

Ch.9

Ch.10

Ch.11

Ch.12

Ch.13

Ch.14

Ch.15

Closed

Ch.1

But. 1&2

Ch.2

Ch.3

Ch.4

Closed

Ch.5

Ch.6

But. 3

Ch.7

Ch.8

Closed

Ch.9

Ch.10

Ch.11

Ch.12

Ch.13

Ch.14

Ch.15

Closed

If a channel that is 

already closed is 

selected during the 

A

utolearn session, 

all oper

ations are 

simply discarded. 

Once a channel is 

closed it can nev

er 

be selected for an

sort of A

utolearn 

activit

y.

Ch.1

But. 1&2

Ch.2

Ch.3

Ch.4

Closed

Ch.5

Ch.6

But. 3

Ch.7

Ch.8

Closed

Ch.9

Ch.10

Ch.11

Ch.12

Ch.13

Ch.14

Ch.15

Closed

It is possible to 

select multiple 

buttons for learning 

during the 

 

A

utolearn process. 

The button com

-

bination is alw

ays 

accepted in the 

association table on 

the tr

ailing edge of 

the button tr

ansac

-

tion.

Ch.1

But. 1&2

Ch.6

But. 3

Enter Autolearn

with Ch. 2 Jumper

Fitted

Time

Association T

able

B1&2

B1
B2
B3

Change to

Ch. 6

Button 3

associated with

Ch. 6

Change to Ch. 8

No button accepted

because channel is closed

Change to Ch. 1

Button 1&2 associated

with Ch. 1

Jumper J1 Removed

Channel Association Table

finalised

S

ECTION

 9

APPENDICES

Содержание Nova Helix

Страница 1: ...Nova Helix Operation Manual Centurion Systems Pty Ltd www centsys com r e c e i v e r...

Страница 2: ...without obligation to notify any persons of any such revisions or changes Additionally Centurion Systems Pty Ltd makes no representations or warranties with respect to this manual No part of this docu...

Страница 3: ...ation 5 2 Simultaneous Primary Channel Activation 5 3 Non Volatile Latches Sticky Latches 5 4 Beep On Activation 6 Disabling Jumpers J1 and J2 7 Configuring the Special Features 8 SmartSwitch II Inter...

Страница 4: ...ivation settings for all channels These settings include enabling disabling latching and panic functionality In addition it is possible to adjust the pulse time on pulsed channels with the following p...

Страница 5: ...the physical output but is a convenient way to describe the collective functionality that a transmitter activates As an example consider the case in Figure 2 A multichannel receiver is used to control...

Страница 6: ...ividually the channels are configured with the following activation settings Channel 1 has a one second pulse time Channel 2 has a four second pulse time Channel 4 is a latching channel When the chann...

Страница 7: ...annel jumpers behave differently when discussing the SmartSwitch II interface The jumpers are used to select a 4 bit binary address that addresses a particular SmartSwitch II device on the interface b...

Страница 8: ...3 Channel 8 8 4 Channel 9 9 1 4 Channel 10 10 2 4 Channel 11 11 1 2 4 Channel 12 12 3 4 Channel 13 13 1 3 4 Channel 14 14 2 3 4 Channel 15 15 1 2 3 4 TABLE 2 CHANNEL JUMPER TO SMARTSWITCH II DEVICE MA...

Страница 9: ...accessible through the learning interface four channel jumpers hence 15 channels but none of the channels are primary channels The single channel variants have one primary channel channel 1 and cannot...

Страница 10: ...ation in particular the LED on the receiver will begin to flash slowly the buzzer will emit a short double beep and the channel functionality will activate 6 The button can be released once the learni...

Страница 11: ...button is pressed refer to points 6 a and 6 b below for further clarification c The button learning process is not finalised 5 Once the three second period has elapsed the LED will turn on again and...

Страница 12: ...on presses 6 While the receiver is in demastering mode any mastered button that is pressed for three or more seconds but less than 10 seconds and is associated with the functionality that the receiver...

Страница 13: ...the button is released in this window it will simply be demastered refer to the previous section Demastering Buttons for further information on this operation b Do nothing because the button being de...

Страница 14: ...to the specified channel Learns a button to the default channel channel 1 Autolearn Mode Channel Specified No Channel Specified Bulk Demaster Channel Bulk Demaster All J2 Memory Blank Memory Non Blank...

Страница 15: ...on has been demastered it can be remastered There are two methods to achieve this 4 2 1 Link Learn Remastering 1 To remaster a remote start by entering link learn mode For reference follow steps 1 and...

Страница 16: ...and that the button is a demastered button Refer to Appendix A on page 30 for a description of the LED and buzzer feedback 6 Once the demastering period has elapsed minimum three seconds the LED will...

Страница 17: ...le This table will be used for all buttons learned into memory during the actual Autolearn procedure Autolearn mode is also limited to a maximum of 7 days before it times out This prevents a user from...

Страница 18: ...an example of the Autolearn configuration procedure 8 Once the association table has been finalised remove jumper J1 This confirms the mapping and enters Autolearn mode The buzzer will beep four time...

Страница 19: ...ettings Memory Erase operation is performed Table 5 documents the settings that are erased in each of the erase cases Channel Erase Transmitter Memory Erase Settings Memory Erase Clears channel compar...

Страница 20: ...4 Holiday lockout or equivalent bi stable function Channel 15 Duress or alarm panic activation Simultaneous Activation Sticky Latch Beep On Activation Special Feature Setting Enabled Enabled Disabled...

Страница 21: ...ntire Transmitter Memory space Resets latch settings on channel 1 Resets panic settings on channel 1 Restores default relay pulse time Clears the SmartSwitch II device output that may be active in the...

Страница 22: ...n channel jumper C1 only To set channel 11 a SmartSwitch II device output place links on channel jumpers C1 C2 and C4 the binary combination of C1 C2 and C4 that results in 11 b 1011 Proceed as per th...

Страница 23: ...ed to step 10 9 After the three second window the LED will switch off and start flashing once per second Counting LED flashes or using a watch to keep track of the number of seconds that pass will det...

Страница 24: ...ature on all receiver variants that allows the receiver to restore its output state on power loss When power is restored the output will assume the state it last reflected prior to the receiver losing...

Страница 25: ...er to set its output to the output state of the receiver s channel prior to power loss SmartSwitch II device restores its output state when its power is restored Subsequently assuming power is restore...

Страница 26: ...f the user The Nova Helix range includes functionality to disable the jumpers With a master remote the jumpers may be re enabled at any stage The following procedure documents disabling the jumper int...

Страница 27: ...e is to be configured Channel jumpers 3 and 4 determine which of the special features is being configured Linking function jumpers J1 or J2 determines whether the special feature being configured is b...

Страница 28: ...is important is that the devices share the same ground rail Up to 15 SmartSwitch II devices can be wired in a daisy chained bus configuration to the receiver SmartSwitch II devices are addressable Eac...

Страница 29: ...r would like to distribute multiple items garden lights for example in physically different areas but have all of them respond to the same remote control button activation The network is limited to 15...

Страница 30: ...3 Second Learn Period Button Released Button Pressed 3 Second Learn Period Button Released Button Pressed 3 Second Learn Period Button Released Button Pressed 3 Second Learn Period Button Released Ma...

Страница 31: ...ttons are pressed the Any Button property is removed from Ch 2 and shifted to Ch 6 when the Ch 6 jumper setting is configured on the Channel Jumpers Ch 1 Ch 2 Ch 3 Ch 4 Closed Ch 5 Ch 6 But 3 Ch 7 Ch...

Страница 32: ...signal and captures the transmit ter information The receiver logic processes the button transaction and determines that channel 3 must be activated The signal splitter in the output logic block rout...