APPENDIX A
CENTROID CNC12 PROBE CONFIGURATION
(see control manual for additional information)
CNC12 control system parameter recommended basic settings SAE inch (mm)
Parameter
Setting
Description
11
50769
PLC input, probe signal
12
10
Tool library number for probe
13
0.020 (0.508)
Clearance amount nominal
14
30
(762)
Fast Probing Rate
15
3
(76.2)
Slow Probing Rate
16
5
(127)
Maximum Search Distance
18
50771
PLC input, Spindle Inhibit/probe connected
120
0.020 (0.508)
Probe stuck clearance amount
121
0.020 (0.508)
Grid digitizing minimum Z pullback
122
0.0002 (0.005)
Grid digitizing dead band distance
123
0
Radial clearance move
151
0
Repeatability tolerance
153
1
Probe protection enable
155
0
Probe type enable
186
1
Probe stuck retry disable
366
1
Probe Deceleration Multiplier
Probe Jog Parameters
control jog speed when probe is connected. Probe must decelerate to stop when
contacting a surface without exceeding overtravel limits. See probe sepcifications. Probe will be
damaged if over travel limit is exceeded by any amount.
Axis Probe Slow Jog
Probe Fast Jog(-)
Probe Fast Jog(+)
1
25
150
150
2
25
150
150
3
25
75
150
4
25
100
100
Note:
In this example axis 3 is the Z axis which only has 0.150 inches of overtravel limit in the (-)
direction. Axis 4 is a rotary axis overtravel will depend on distance from center of rotation.
REQUIRED CONNECTION CABLE CNC12 SYSTEMS
Probe Cable PN: 11085 is used on most CNC12 systems. See the schematic diagram of this cable in
appendix B. Refer to the installation manual of the control if this cable is not appropriate.